Cargando…

CO(2) Laser Fabrication of PMMA Microfluidic Double T-Junction Device with Modified Inlet-Angle for Cost-Effective PCR Application

The formation of uniform droplets and the control of their size, shape and monodispersity are of utmost importance in droplet-based microfluidic systems. The size of the droplets is precisely tuned by the channel geometry, the surface interfacial tension, the shear force and fluid velocity. In addit...

Descripción completa

Detalles Bibliográficos
Autores principales: Nasser, Gamal A., Fath El-Bab, Ahmed M.R., Abdel-Mawgood, Ahmed L., Mohamed, Hisham, Saleh, Abdelatty M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6843704/
https://www.ncbi.nlm.nih.gov/pubmed/31600884
http://dx.doi.org/10.3390/mi10100678
_version_ 1783468279052894208
author Nasser, Gamal A.
Fath El-Bab, Ahmed M.R.
Abdel-Mawgood, Ahmed L.
Mohamed, Hisham
Saleh, Abdelatty M.
author_facet Nasser, Gamal A.
Fath El-Bab, Ahmed M.R.
Abdel-Mawgood, Ahmed L.
Mohamed, Hisham
Saleh, Abdelatty M.
author_sort Nasser, Gamal A.
collection PubMed
description The formation of uniform droplets and the control of their size, shape and monodispersity are of utmost importance in droplet-based microfluidic systems. The size of the droplets is precisely tuned by the channel geometry, the surface interfacial tension, the shear force and fluid velocity. In addition, the fabrication technique and selection of materials are essential to reduce the fabrication cost and time. In this paper, for reducing the fabrication cost Polymethyl methacrylate (PMMA) sheet is used with direct write laser technique by VERSA CO(2) laser VLS3.5. This laser writing technique gives minimum channel width of about [Formula: see text] , which limit miniaturizing the droplet. To overcome this, modification on double T-junction (DTJ) channel geometry has been done by modifying the channel inlets angles. First, a two-dimensional (2D) simulation has been done to study the effect of the new channel geometry modification on droplet size, droplets distribution inside the channel, and its throughput. The fabricated modified DTJ gives the minimum droplet diameter of [Formula: see text] , while DTJ channel produced droplet diameter of [Formula: see text] at the same conditions. Moreover, the modified double T-junction (MDTJ) decreases the variation in droplets diameter at the same flow rates by [Formula: see text] than DTJ. This low variation in the droplet diameter is suitable for repeatability of the DNA detection results. The MDTJ also enhanced the droplet generation frequency by [Formula: see text] more than the DTJ channel. The uniformity of droplet distribution inside the channel was enhanced by [Formula: see text] compared to the DTJ channel geometry. This fabrication technique eliminates the need for a photomask and cleanroom environment in addition shortening the cost and time. It takes only [Formula: see text] for fabrication. The minimum generated droplet diameter is within [Formula: see text] with more than [Formula: see text] droplets per second (at [Formula: see text]. oil flow rate). The device is a high-throughput and low-cost micro-droplet formation aimed to be as a front-end to a dynamic droplet digital PCR (ddPCR) platform for use in resource-limited environment.
format Online
Article
Text
id pubmed-6843704
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-68437042019-11-25 CO(2) Laser Fabrication of PMMA Microfluidic Double T-Junction Device with Modified Inlet-Angle for Cost-Effective PCR Application Nasser, Gamal A. Fath El-Bab, Ahmed M.R. Abdel-Mawgood, Ahmed L. Mohamed, Hisham Saleh, Abdelatty M. Micromachines (Basel) Article The formation of uniform droplets and the control of their size, shape and monodispersity are of utmost importance in droplet-based microfluidic systems. The size of the droplets is precisely tuned by the channel geometry, the surface interfacial tension, the shear force and fluid velocity. In addition, the fabrication technique and selection of materials are essential to reduce the fabrication cost and time. In this paper, for reducing the fabrication cost Polymethyl methacrylate (PMMA) sheet is used with direct write laser technique by VERSA CO(2) laser VLS3.5. This laser writing technique gives minimum channel width of about [Formula: see text] , which limit miniaturizing the droplet. To overcome this, modification on double T-junction (DTJ) channel geometry has been done by modifying the channel inlets angles. First, a two-dimensional (2D) simulation has been done to study the effect of the new channel geometry modification on droplet size, droplets distribution inside the channel, and its throughput. The fabricated modified DTJ gives the minimum droplet diameter of [Formula: see text] , while DTJ channel produced droplet diameter of [Formula: see text] at the same conditions. Moreover, the modified double T-junction (MDTJ) decreases the variation in droplets diameter at the same flow rates by [Formula: see text] than DTJ. This low variation in the droplet diameter is suitable for repeatability of the DNA detection results. The MDTJ also enhanced the droplet generation frequency by [Formula: see text] more than the DTJ channel. The uniformity of droplet distribution inside the channel was enhanced by [Formula: see text] compared to the DTJ channel geometry. This fabrication technique eliminates the need for a photomask and cleanroom environment in addition shortening the cost and time. It takes only [Formula: see text] for fabrication. The minimum generated droplet diameter is within [Formula: see text] with more than [Formula: see text] droplets per second (at [Formula: see text]. oil flow rate). The device is a high-throughput and low-cost micro-droplet formation aimed to be as a front-end to a dynamic droplet digital PCR (ddPCR) platform for use in resource-limited environment. MDPI 2019-10-09 /pmc/articles/PMC6843704/ /pubmed/31600884 http://dx.doi.org/10.3390/mi10100678 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Nasser, Gamal A.
Fath El-Bab, Ahmed M.R.
Abdel-Mawgood, Ahmed L.
Mohamed, Hisham
Saleh, Abdelatty M.
CO(2) Laser Fabrication of PMMA Microfluidic Double T-Junction Device with Modified Inlet-Angle for Cost-Effective PCR Application
title CO(2) Laser Fabrication of PMMA Microfluidic Double T-Junction Device with Modified Inlet-Angle for Cost-Effective PCR Application
title_full CO(2) Laser Fabrication of PMMA Microfluidic Double T-Junction Device with Modified Inlet-Angle for Cost-Effective PCR Application
title_fullStr CO(2) Laser Fabrication of PMMA Microfluidic Double T-Junction Device with Modified Inlet-Angle for Cost-Effective PCR Application
title_full_unstemmed CO(2) Laser Fabrication of PMMA Microfluidic Double T-Junction Device with Modified Inlet-Angle for Cost-Effective PCR Application
title_short CO(2) Laser Fabrication of PMMA Microfluidic Double T-Junction Device with Modified Inlet-Angle for Cost-Effective PCR Application
title_sort co(2) laser fabrication of pmma microfluidic double t-junction device with modified inlet-angle for cost-effective pcr application
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6843704/
https://www.ncbi.nlm.nih.gov/pubmed/31600884
http://dx.doi.org/10.3390/mi10100678
work_keys_str_mv AT nassergamala co2laserfabricationofpmmamicrofluidicdoubletjunctiondevicewithmodifiedinletangleforcosteffectivepcrapplication
AT fathelbabahmedmr co2laserfabricationofpmmamicrofluidicdoubletjunctiondevicewithmodifiedinletangleforcosteffectivepcrapplication
AT abdelmawgoodahmedl co2laserfabricationofpmmamicrofluidicdoubletjunctiondevicewithmodifiedinletangleforcosteffectivepcrapplication
AT mohamedhisham co2laserfabricationofpmmamicrofluidicdoubletjunctiondevicewithmodifiedinletangleforcosteffectivepcrapplication
AT salehabdelattym co2laserfabricationofpmmamicrofluidicdoubletjunctiondevicewithmodifiedinletangleforcosteffectivepcrapplication