Release kinetics of the model protein FITC-BSA from different polymer-coated bovine bone substitutes
BACKGROUND: Controlled release of proteins bound to conventional bone substitutes is still insufficient. Therefore, this study evaluates in-vitro release kinetics of the model protein FITC-BSA (fluorescein conjugated bovine serum albumine) from insoluble bovine collagenous bone matrices (ICBM) with...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6844035/ https://www.ncbi.nlm.nih.gov/pubmed/31711509 http://dx.doi.org/10.1186/s13005-019-0211-y |
Sumario: | BACKGROUND: Controlled release of proteins bound to conventional bone substitutes is still insufficient. Therefore, this study evaluates in-vitro release kinetics of the model protein FITC-BSA (fluorescein conjugated bovine serum albumine) from insoluble bovine collagenous bone matrices (ICBM) with different polymer coatings. Analyzes aim at comparing FITC-BSA release from uncoated versus coated ICBM over time to find bone substitute coatings with consistent release profiles. METHODS: Release kinetics of FITC-BSA from uncoated as well as coated ICBM with five different polymers (RESOMER R 203 H, RG 503 H, RG 504 H, RG 505, L 206 S) were measured over a period of 11 days (d). Measurements were conducted after 6 h (h), 12 h, 24 h, 3 d, 5 d, 7 d, 9 d and 11 d with six samples for each coated ICBM. Two groups were formed (1) with and (2) without medium change at times of measurement. For each group ANOVA with post-hoc Bonferroni testing was used. Scanning electron microscopy assessed morphologic differences between ICBM coating. RESULTS: In group 1 approx. 70% of FITC-BSA release from uncoated ICBM occurred after 6 h compared to approx. 50% in group 2. Only polymers with medium inherent viscosity, i.e. RESOMER RG 503 H, constantly showed significantly more FITC-BSA release throughout 11 d than uncoated ICBM (p = 0.007). The same was found for group 2 (p = 0.005). No significant differences between PLA and PLGA polymers were found. Scanning electron microscopy results indicate a weak adhesion of polymer coatings to ICBM explaining its rather weak retentive effect on overall FITC-BSA release. CONCLUSIONS: Medium molecular size polymers reduce the overall released FITC-BSA from ICBM over time. In clinical practice these polymers may prove ideal for bone substitute materials. |
---|