Cargando…
Equal tibial component fixation of a mobile-bearing and fixed-bearing medial unicompartmental knee arthroplasty: a randomized controlled RSA study with 2-year follow-up
Background and purpose — Differences in stress distribution in a mobile-bearing and fixed-bearing unicompartmental knee arthroplasty (UKA) design might lead to a difference in fixation of the tibial component. We compared tibial component migration of a mobile-bearing (MB) UKA and a fixed-bearing (F...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Taylor & Francis
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6844442/ https://www.ncbi.nlm.nih.gov/pubmed/31293193 http://dx.doi.org/10.1080/17453674.2019.1639965 |
_version_ | 1783468439072931840 |
---|---|
author | Koppens, Daan Rytter, Søren Munk, Stig Dalsgaard, Jesper Sørensen, Ole G Hansen, Torben B Stilling, Maiken |
author_facet | Koppens, Daan Rytter, Søren Munk, Stig Dalsgaard, Jesper Sørensen, Ole G Hansen, Torben B Stilling, Maiken |
author_sort | Koppens, Daan |
collection | PubMed |
description | Background and purpose — Differences in stress distribution in a mobile-bearing and fixed-bearing unicompartmental knee arthroplasty (UKA) design might lead to a difference in fixation of the tibial component. We compared tibial component migration of a mobile-bearing (MB) UKA and a fixed-bearing (FB) UKA using radiostereometric analysis. Patients and methods — In a randomized, patient-blinded clinical trial 62 patients received either the MB Oxford UKA or the FB Sigma UKA. The patients were followed for 24 months with radiostereometric analysis. Clinical outcome was assessed with Oxford Knee Score (OKS), RAND-36 and leg extension power. Results — Migration of the tibial components was similar between groups throughout follow-up. At 12 months, MTPM of the tibial component was 0.44 mm (95% CI 0.34–0.55) for the MB group and 0.40 mm (CI 0.31–0.50) for the FB group. Between 12 and 24 months, the tibial components migrated with a median MTPM increase of 0.03 mm (CI –0.02 to 0.08) in the MB group and 0.03 mm (CI –0.02 to 0.07) in the FB group. Continuous migration of the tibial component was found for 1 MB UKA and 2 FB UKAs. Both groups showed similar and clinically relevant improvement in clinical outcome. Interpretation — MB and FB tibial components had similar good fixation and clinical improvement until 2 years. Based on this study, a low 5- to 10-year revision rate can be expected for both implants. |
format | Online Article Text |
id | pubmed-6844442 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Taylor & Francis |
record_format | MEDLINE/PubMed |
spelling | pubmed-68444422019-12-01 Equal tibial component fixation of a mobile-bearing and fixed-bearing medial unicompartmental knee arthroplasty: a randomized controlled RSA study with 2-year follow-up Koppens, Daan Rytter, Søren Munk, Stig Dalsgaard, Jesper Sørensen, Ole G Hansen, Torben B Stilling, Maiken Acta Orthop Article Background and purpose — Differences in stress distribution in a mobile-bearing and fixed-bearing unicompartmental knee arthroplasty (UKA) design might lead to a difference in fixation of the tibial component. We compared tibial component migration of a mobile-bearing (MB) UKA and a fixed-bearing (FB) UKA using radiostereometric analysis. Patients and methods — In a randomized, patient-blinded clinical trial 62 patients received either the MB Oxford UKA or the FB Sigma UKA. The patients were followed for 24 months with radiostereometric analysis. Clinical outcome was assessed with Oxford Knee Score (OKS), RAND-36 and leg extension power. Results — Migration of the tibial components was similar between groups throughout follow-up. At 12 months, MTPM of the tibial component was 0.44 mm (95% CI 0.34–0.55) for the MB group and 0.40 mm (CI 0.31–0.50) for the FB group. Between 12 and 24 months, the tibial components migrated with a median MTPM increase of 0.03 mm (CI –0.02 to 0.08) in the MB group and 0.03 mm (CI –0.02 to 0.07) in the FB group. Continuous migration of the tibial component was found for 1 MB UKA and 2 FB UKAs. Both groups showed similar and clinically relevant improvement in clinical outcome. Interpretation — MB and FB tibial components had similar good fixation and clinical improvement until 2 years. Based on this study, a low 5- to 10-year revision rate can be expected for both implants. Taylor & Francis 2019-12 2019-07-11 /pmc/articles/PMC6844442/ /pubmed/31293193 http://dx.doi.org/10.1080/17453674.2019.1639965 Text en © 2019 The Author(s). Published by Taylor & Francis on behalf of the Nordic Orthopedic Federation http://creativecommons.org/licenses/by/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Article Koppens, Daan Rytter, Søren Munk, Stig Dalsgaard, Jesper Sørensen, Ole G Hansen, Torben B Stilling, Maiken Equal tibial component fixation of a mobile-bearing and fixed-bearing medial unicompartmental knee arthroplasty: a randomized controlled RSA study with 2-year follow-up |
title | Equal tibial component fixation of a mobile-bearing and fixed-bearing medial unicompartmental knee arthroplasty: a randomized controlled RSA study with 2-year follow-up |
title_full | Equal tibial component fixation of a mobile-bearing and fixed-bearing medial unicompartmental knee arthroplasty: a randomized controlled RSA study with 2-year follow-up |
title_fullStr | Equal tibial component fixation of a mobile-bearing and fixed-bearing medial unicompartmental knee arthroplasty: a randomized controlled RSA study with 2-year follow-up |
title_full_unstemmed | Equal tibial component fixation of a mobile-bearing and fixed-bearing medial unicompartmental knee arthroplasty: a randomized controlled RSA study with 2-year follow-up |
title_short | Equal tibial component fixation of a mobile-bearing and fixed-bearing medial unicompartmental knee arthroplasty: a randomized controlled RSA study with 2-year follow-up |
title_sort | equal tibial component fixation of a mobile-bearing and fixed-bearing medial unicompartmental knee arthroplasty: a randomized controlled rsa study with 2-year follow-up |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6844442/ https://www.ncbi.nlm.nih.gov/pubmed/31293193 http://dx.doi.org/10.1080/17453674.2019.1639965 |
work_keys_str_mv | AT koppensdaan equaltibialcomponentfixationofamobilebearingandfixedbearingmedialunicompartmentalkneearthroplastyarandomizedcontrolledrsastudywith2yearfollowup AT ryttersøren equaltibialcomponentfixationofamobilebearingandfixedbearingmedialunicompartmentalkneearthroplastyarandomizedcontrolledrsastudywith2yearfollowup AT munkstig equaltibialcomponentfixationofamobilebearingandfixedbearingmedialunicompartmentalkneearthroplastyarandomizedcontrolledrsastudywith2yearfollowup AT dalsgaardjesper equaltibialcomponentfixationofamobilebearingandfixedbearingmedialunicompartmentalkneearthroplastyarandomizedcontrolledrsastudywith2yearfollowup AT sørensenoleg equaltibialcomponentfixationofamobilebearingandfixedbearingmedialunicompartmentalkneearthroplastyarandomizedcontrolledrsastudywith2yearfollowup AT hansentorbenb equaltibialcomponentfixationofamobilebearingandfixedbearingmedialunicompartmentalkneearthroplastyarandomizedcontrolledrsastudywith2yearfollowup AT stillingmaiken equaltibialcomponentfixationofamobilebearingandfixedbearingmedialunicompartmentalkneearthroplastyarandomizedcontrolledrsastudywith2yearfollowup |