The ability to measure oxygen consumption rates of a living organism in real-time provides an indirect method of monitoring dynamic changes in metabolism reflecting organismal level mitochondrial function. In this study, we assessed the Loligo Systems microplate system for measuring individual respi...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6845526/ http://dx.doi.org/10.1093/geroni/igz038.3347 |
_version_ | 1783468686639628288 |
---|---|
author | Turner, Ashley N Hoffman, Jessica M Powell, Mickie L Sammy, Melissa J Moellering, Douglas R Nagy, Tim R Austad, Steven N Smith, Daniel L |
author_facet | Turner, Ashley N Hoffman, Jessica M Powell, Mickie L Sammy, Melissa J Moellering, Douglas R Nagy, Tim R Austad, Steven N Smith, Daniel L |
author_sort | Turner, Ashley N |
collection | PubMed |
description | The ability to measure oxygen consumption rates of a living organism in real-time provides an indirect method of monitoring dynamic changes in metabolism reflecting organismal level mitochondrial function. In this study, we assessed the Loligo Systems microplate system for measuring individual respiration in small organisms. This included adult nematodes (Caenorhabditis elegans, N2), zebrafish embryos (Danio rerio, AB), and adult fruit flies (Drosophila melanogaster, w1118). Organisms were placed inside 80 µL glass chambers on a 24-well microplate atop a 24-channel optical fluorescence oxygen reading device. Adult nematodes and zebrafish embryos were in liquid culture, M9 buffer and egg water respectively, and the adult flies were in room air. The microplate and reader were placed inside an incubator for temperature control. A silicone gasket with a thin liner was used to seal the chambers. Reference standard oxygen consumption (respiration) of single and multiple adult nematodes (n=1–4 animals/well), zebrafish embryos (n=1–4 animals/well), and adult flies (n=1–2 animals/well) in the microplate system were achieved. Significant differences across numbers of animals/well and by sex were observed. Validation experiments of the oxygen consumption rates measured in C. elegans in parallel with Seahorse extracellular flux (XF) experiments are underway. The Loligo Systems microplate system offers a non-invasive, non-destructive method to measure real-time respiration in smaller organisms. These data provide preliminary evidence for utility of the system for a variety of biomedical applications that relate to organismal and mitochondrial function/dysfunction, including research in the basic biology of aging in these highly-utilized, pre-clinical, genetic model organisms. |
format | Online Article Text |
id | pubmed-6845526 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-68455262019-11-18 ASSESSMENT OF A MICROPLATE SYSTEM FOR MEASURING INDIVIDUAL REAL-TIME RESPIRATION IN SMALL MODEL ORGANISMS OF AGING Turner, Ashley N Hoffman, Jessica M Powell, Mickie L Sammy, Melissa J Moellering, Douglas R Nagy, Tim R Austad, Steven N Smith, Daniel L Innov Aging Session Lb2570 (Late Breaking Poster) The ability to measure oxygen consumption rates of a living organism in real-time provides an indirect method of monitoring dynamic changes in metabolism reflecting organismal level mitochondrial function. In this study, we assessed the Loligo Systems microplate system for measuring individual respiration in small organisms. This included adult nematodes (Caenorhabditis elegans, N2), zebrafish embryos (Danio rerio, AB), and adult fruit flies (Drosophila melanogaster, w1118). Organisms were placed inside 80 µL glass chambers on a 24-well microplate atop a 24-channel optical fluorescence oxygen reading device. Adult nematodes and zebrafish embryos were in liquid culture, M9 buffer and egg water respectively, and the adult flies were in room air. The microplate and reader were placed inside an incubator for temperature control. A silicone gasket with a thin liner was used to seal the chambers. Reference standard oxygen consumption (respiration) of single and multiple adult nematodes (n=1–4 animals/well), zebrafish embryos (n=1–4 animals/well), and adult flies (n=1–2 animals/well) in the microplate system were achieved. Significant differences across numbers of animals/well and by sex were observed. Validation experiments of the oxygen consumption rates measured in C. elegans in parallel with Seahorse extracellular flux (XF) experiments are underway. The Loligo Systems microplate system offers a non-invasive, non-destructive method to measure real-time respiration in smaller organisms. These data provide preliminary evidence for utility of the system for a variety of biomedical applications that relate to organismal and mitochondrial function/dysfunction, including research in the basic biology of aging in these highly-utilized, pre-clinical, genetic model organisms. Oxford University Press 2019-11-08 /pmc/articles/PMC6845526/ http://dx.doi.org/10.1093/geroni/igz038.3347 Text en © The Author(s) 2019. Published by Oxford University Press on behalf of The Gerontological Society of America. http://creativecommons.org/licenses/by/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Session Lb2570 (Late Breaking Poster) Turner, Ashley N Hoffman, Jessica M Powell, Mickie L Sammy, Melissa J Moellering, Douglas R Nagy, Tim R Austad, Steven N Smith, Daniel L ASSESSMENT OF A MICROPLATE SYSTEM FOR MEASURING INDIVIDUAL REAL-TIME RESPIRATION IN SMALL MODEL ORGANISMS OF AGING |
title | ASSESSMENT OF A MICROPLATE SYSTEM FOR MEASURING INDIVIDUAL REAL-TIME RESPIRATION IN SMALL MODEL ORGANISMS OF AGING |
title_full | ASSESSMENT OF A MICROPLATE SYSTEM FOR MEASURING INDIVIDUAL REAL-TIME RESPIRATION IN SMALL MODEL ORGANISMS OF AGING |
title_fullStr | ASSESSMENT OF A MICROPLATE SYSTEM FOR MEASURING INDIVIDUAL REAL-TIME RESPIRATION IN SMALL MODEL ORGANISMS OF AGING |
title_full_unstemmed | ASSESSMENT OF A MICROPLATE SYSTEM FOR MEASURING INDIVIDUAL REAL-TIME RESPIRATION IN SMALL MODEL ORGANISMS OF AGING |
title_short | ASSESSMENT OF A MICROPLATE SYSTEM FOR MEASURING INDIVIDUAL REAL-TIME RESPIRATION IN SMALL MODEL ORGANISMS OF AGING |
title_sort | assessment of a microplate system for measuring individual real-time respiration in small model organisms of aging |
topic | Session Lb2570 (Late Breaking Poster) |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6845526/ http://dx.doi.org/10.1093/geroni/igz038.3347 |
work_keys_str_mv | AT turnerashleyn assessmentofamicroplatesystemformeasuringindividualrealtimerespirationinsmallmodelorganismsofaging AT hoffmanjessicam assessmentofamicroplatesystemformeasuringindividualrealtimerespirationinsmallmodelorganismsofaging AT powellmickiel assessmentofamicroplatesystemformeasuringindividualrealtimerespirationinsmallmodelorganismsofaging AT sammymelissaj assessmentofamicroplatesystemformeasuringindividualrealtimerespirationinsmallmodelorganismsofaging AT moelleringdouglasr assessmentofamicroplatesystemformeasuringindividualrealtimerespirationinsmallmodelorganismsofaging AT nagytimr assessmentofamicroplatesystemformeasuringindividualrealtimerespirationinsmallmodelorganismsofaging AT austadstevenn assessmentofamicroplatesystemformeasuringindividualrealtimerespirationinsmallmodelorganismsofaging AT smithdaniell assessmentofamicroplatesystemformeasuringindividualrealtimerespirationinsmallmodelorganismsofaging |