Fracture of a popliteal nitinol stent and pseudoaneurysm: a case report and review of the literature
There is a lack of reports onr stent fracture with pseudoaneurysm formation in the femoropopliteal artery, which can cause restenosis or occlusion of the treated arterial segment. We present a case of a large pseudoaneurysm of the popliteal artery that was observed 18 months after popliteal stenting...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6847879/ https://www.ncbi.nlm.nih.gov/pubmed/31737245 http://dx.doi.org/10.1093/jscr/rjz312 |
_version_ | 1783468993915387904 |
---|---|
author | dos Reis, José Maciel Caldas Kudo, Fábio Akimaro do Carmo Bastos, Moisés |
author_facet | dos Reis, José Maciel Caldas Kudo, Fábio Akimaro do Carmo Bastos, Moisés |
author_sort | dos Reis, José Maciel Caldas |
collection | PubMed |
description | There is a lack of reports onr stent fracture with pseudoaneurysm formation in the femoropopliteal artery, which can cause restenosis or occlusion of the treated arterial segment. We present a case of a large pseudoaneurysm of the popliteal artery that was observed 18 months after popliteal stenting using a self-expandable nitinol stent. We describe an endovascular approach to overcome this severe complication. Stent fractures are an often overlooked complication of femoropopliteal stenting and can be associated with serious diseases. The popliteal artery was successfully treated using self-expandable Viabahn endoprosthesis. |
format | Online Article Text |
id | pubmed-6847879 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-68478792019-11-15 Fracture of a popliteal nitinol stent and pseudoaneurysm: a case report and review of the literature dos Reis, José Maciel Caldas Kudo, Fábio Akimaro do Carmo Bastos, Moisés J Surg Case Rep Case Report There is a lack of reports onr stent fracture with pseudoaneurysm formation in the femoropopliteal artery, which can cause restenosis or occlusion of the treated arterial segment. We present a case of a large pseudoaneurysm of the popliteal artery that was observed 18 months after popliteal stenting using a self-expandable nitinol stent. We describe an endovascular approach to overcome this severe complication. Stent fractures are an often overlooked complication of femoropopliteal stenting and can be associated with serious diseases. The popliteal artery was successfully treated using self-expandable Viabahn endoprosthesis. Oxford University Press 2019-11-11 /pmc/articles/PMC6847879/ /pubmed/31737245 http://dx.doi.org/10.1093/jscr/rjz312 Text en Published by Oxford University Press and JSCR Publishing Ltd. All rights reserved. © The Author(s) 2019. http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com |
spellingShingle | Case Report dos Reis, José Maciel Caldas Kudo, Fábio Akimaro do Carmo Bastos, Moisés Fracture of a popliteal nitinol stent and pseudoaneurysm: a case report and review of the literature |
title | Fracture of a popliteal nitinol stent and pseudoaneurysm: a case report and review of the literature |
title_full | Fracture of a popliteal nitinol stent and pseudoaneurysm: a case report and review of the literature |
title_fullStr | Fracture of a popliteal nitinol stent and pseudoaneurysm: a case report and review of the literature |
title_full_unstemmed | Fracture of a popliteal nitinol stent and pseudoaneurysm: a case report and review of the literature |
title_short | Fracture of a popliteal nitinol stent and pseudoaneurysm: a case report and review of the literature |
title_sort | fracture of a popliteal nitinol stent and pseudoaneurysm: a case report and review of the literature |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6847879/ https://www.ncbi.nlm.nih.gov/pubmed/31737245 http://dx.doi.org/10.1093/jscr/rjz312 |
work_keys_str_mv | AT dosreisjosemacielcaldas fractureofapoplitealnitinolstentandpseudoaneurysmacasereportandreviewoftheliterature AT kudofabioakimaro fractureofapoplitealnitinolstentandpseudoaneurysmacasereportandreviewoftheliterature AT docarmobastosmoises fractureofapoplitealnitinolstentandpseudoaneurysmacasereportandreviewoftheliterature |