Cargando…
Diagnostic accuracy of flat-panel computed tomography in assessing cerebral perfusion in comparison with perfusion computed tomography and perfusion magnetic resonance: a systematic review
PURPOSE: Flat-panel computed tomography (FP-CT) is increasingly available in angiographic rooms and hybrid OR’s. Considering its easy access, cerebral imaging using FP-CT is an appealing modality for intra-procedural applications. The purpose of this systematic review is to assess the diagnostic acc...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6848034/ https://www.ncbi.nlm.nih.gov/pubmed/31523757 http://dx.doi.org/10.1007/s00234-019-02285-y |
_version_ | 1783469005789462528 |
---|---|
author | Stille, Ernst L. Viozzi, Ilaria ter Laan, Mark Meijer, Frederick J.A. Futterer, Jurgen J. Rovers, Maroeska M. |
author_facet | Stille, Ernst L. Viozzi, Ilaria ter Laan, Mark Meijer, Frederick J.A. Futterer, Jurgen J. Rovers, Maroeska M. |
author_sort | Stille, Ernst L. |
collection | PubMed |
description | PURPOSE: Flat-panel computed tomography (FP-CT) is increasingly available in angiographic rooms and hybrid OR’s. Considering its easy access, cerebral imaging using FP-CT is an appealing modality for intra-procedural applications. The purpose of this systematic review is to assess the diagnostic accuracy of FP-CT compared with perfusion computed tomography (CTP) and perfusion magnetic resonance (MRP) in cerebral perfusion imaging. METHODS: We performed a systematic literature search in the Cochrane Library, MEDLINE, Embase, and Web of Science up to June 2019 for studies directly comparing FP-CT with either CTP or MRP in vivo. Methodological quality was assessed using the QUADAS-2 tool. Data on diagnostic accuracy was extracted and pooled if possible. RESULTS: We found 11 studies comparing FP-CT with CTP and 5 studies comparing FP-CT with MRP. Most articles were pilot or feasibility studies, focusing on scanning and contrast protocols. All patients studied showed signs of cerebrovascular disease. Half of the studies were animal trials. Quality assessment showed unclear to high risks of bias and low concerns regarding applicability. Five studies reported on diagnostic accuracy; FP-CT shows good sensitivity (range 0.84–1.00) and moderate specificity (range 0.63–0.88) in detecting cerebral blood volume (CBV) lesions. CONCLUSIONS: Even though FP-CT provides similar CBV values and reconstructed blood volume maps as CTP in cerebrovascular disease, additional studies are required in order to reliably compare its diagnostic accuracy with cerebral perfusion imaging. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s00234-019-02285-y) contains supplementary material, which is available to authorized users. |
format | Online Article Text |
id | pubmed-6848034 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-68480342019-11-22 Diagnostic accuracy of flat-panel computed tomography in assessing cerebral perfusion in comparison with perfusion computed tomography and perfusion magnetic resonance: a systematic review Stille, Ernst L. Viozzi, Ilaria ter Laan, Mark Meijer, Frederick J.A. Futterer, Jurgen J. Rovers, Maroeska M. Neuroradiology Interventional Neuroradiology PURPOSE: Flat-panel computed tomography (FP-CT) is increasingly available in angiographic rooms and hybrid OR’s. Considering its easy access, cerebral imaging using FP-CT is an appealing modality for intra-procedural applications. The purpose of this systematic review is to assess the diagnostic accuracy of FP-CT compared with perfusion computed tomography (CTP) and perfusion magnetic resonance (MRP) in cerebral perfusion imaging. METHODS: We performed a systematic literature search in the Cochrane Library, MEDLINE, Embase, and Web of Science up to June 2019 for studies directly comparing FP-CT with either CTP or MRP in vivo. Methodological quality was assessed using the QUADAS-2 tool. Data on diagnostic accuracy was extracted and pooled if possible. RESULTS: We found 11 studies comparing FP-CT with CTP and 5 studies comparing FP-CT with MRP. Most articles were pilot or feasibility studies, focusing on scanning and contrast protocols. All patients studied showed signs of cerebrovascular disease. Half of the studies were animal trials. Quality assessment showed unclear to high risks of bias and low concerns regarding applicability. Five studies reported on diagnostic accuracy; FP-CT shows good sensitivity (range 0.84–1.00) and moderate specificity (range 0.63–0.88) in detecting cerebral blood volume (CBV) lesions. CONCLUSIONS: Even though FP-CT provides similar CBV values and reconstructed blood volume maps as CTP in cerebrovascular disease, additional studies are required in order to reliably compare its diagnostic accuracy with cerebral perfusion imaging. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s00234-019-02285-y) contains supplementary material, which is available to authorized users. Springer Berlin Heidelberg 2019-09-16 2019 /pmc/articles/PMC6848034/ /pubmed/31523757 http://dx.doi.org/10.1007/s00234-019-02285-y Text en © The Author(s) 2019 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Interventional Neuroradiology Stille, Ernst L. Viozzi, Ilaria ter Laan, Mark Meijer, Frederick J.A. Futterer, Jurgen J. Rovers, Maroeska M. Diagnostic accuracy of flat-panel computed tomography in assessing cerebral perfusion in comparison with perfusion computed tomography and perfusion magnetic resonance: a systematic review |
title | Diagnostic accuracy of flat-panel computed tomography in assessing cerebral perfusion in comparison with perfusion computed tomography and perfusion magnetic resonance: a systematic review |
title_full | Diagnostic accuracy of flat-panel computed tomography in assessing cerebral perfusion in comparison with perfusion computed tomography and perfusion magnetic resonance: a systematic review |
title_fullStr | Diagnostic accuracy of flat-panel computed tomography in assessing cerebral perfusion in comparison with perfusion computed tomography and perfusion magnetic resonance: a systematic review |
title_full_unstemmed | Diagnostic accuracy of flat-panel computed tomography in assessing cerebral perfusion in comparison with perfusion computed tomography and perfusion magnetic resonance: a systematic review |
title_short | Diagnostic accuracy of flat-panel computed tomography in assessing cerebral perfusion in comparison with perfusion computed tomography and perfusion magnetic resonance: a systematic review |
title_sort | diagnostic accuracy of flat-panel computed tomography in assessing cerebral perfusion in comparison with perfusion computed tomography and perfusion magnetic resonance: a systematic review |
topic | Interventional Neuroradiology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6848034/ https://www.ncbi.nlm.nih.gov/pubmed/31523757 http://dx.doi.org/10.1007/s00234-019-02285-y |
work_keys_str_mv | AT stilleernstl diagnosticaccuracyofflatpanelcomputedtomographyinassessingcerebralperfusionincomparisonwithperfusioncomputedtomographyandperfusionmagneticresonanceasystematicreview AT viozziilaria diagnosticaccuracyofflatpanelcomputedtomographyinassessingcerebralperfusionincomparisonwithperfusioncomputedtomographyandperfusionmagneticresonanceasystematicreview AT terlaanmark diagnosticaccuracyofflatpanelcomputedtomographyinassessingcerebralperfusionincomparisonwithperfusioncomputedtomographyandperfusionmagneticresonanceasystematicreview AT meijerfrederickja diagnosticaccuracyofflatpanelcomputedtomographyinassessingcerebralperfusionincomparisonwithperfusioncomputedtomographyandperfusionmagneticresonanceasystematicreview AT futtererjurgenj diagnosticaccuracyofflatpanelcomputedtomographyinassessingcerebralperfusionincomparisonwithperfusioncomputedtomographyandperfusionmagneticresonanceasystematicreview AT roversmaroeskam diagnosticaccuracyofflatpanelcomputedtomographyinassessingcerebralperfusionincomparisonwithperfusioncomputedtomographyandperfusionmagneticresonanceasystematicreview |