Feasibility of Percutaneous Dilatational Tracheostomy with a Light Source in the Surgical Intensive Care Unit

BACKGROUND: Although percutaneous dilatational tracheostomy (PDT) under bronchoscopic guidance is feasible in the intensive care unit (ICU), it requires extensive equipment and specialists. The present study evaluated the feasibility of performing PDT with a light source in the surgical ICU. METHODS...

Descripción completa

Detalles Bibliográficos
Autores principales: Baek, Jong-Kwan, Lee, Jung-Sun, Kang, Minchang, Choi, Nak-Jun, Hong, Suk-Kyung
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Society of Critical Care Medicine 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6849057/
https://www.ncbi.nlm.nih.gov/pubmed/31723868
http://dx.doi.org/10.4266/acc.2017.00563
_version_ 1783469129194274816
author Baek, Jong-Kwan
Lee, Jung-Sun
Kang, Minchang
Choi, Nak-Jun
Hong, Suk-Kyung
author_facet Baek, Jong-Kwan
Lee, Jung-Sun
Kang, Minchang
Choi, Nak-Jun
Hong, Suk-Kyung
author_sort Baek, Jong-Kwan
collection PubMed
description BACKGROUND: Although percutaneous dilatational tracheostomy (PDT) under bronchoscopic guidance is feasible in the intensive care unit (ICU), it requires extensive equipment and specialists. The present study evaluated the feasibility of performing PDT with a light source in the surgical ICU. METHODS: The study involved a retrospective review of the outcomes of patients who underwent PDT with a light source performed by a surgery resident under the supervision of a surgical intensivist in the surgical ICU from October 2015 through September 2016. During the procedure, a light wand was inserted into the endotracheal tube after skin incision. Then, the light wand and the endotracheal tube were pulled out slightly, the passage of light through the airway was confirmed, and the relevant point was punctured. RESULTS: Fifty patients underwent PDT with a light source. The average procedural duration was 14.0 ± 7.0 minutes. There were no procedure-associated deaths. Intraoperative complications included minor bleeding in three patients (6%) and paratracheal placement of the tracheostomy tube in one patient (2%); these were immediately resolved by the surgical intensivist. Two patients required conversion to surgical tracheostomy because of the difficulty in light wand insertion into the endotracheal tube and a very narrow trachea, respectively. CONCLUSIONS: PDT with a light source can be performed without bronchoscopy and does not require expensive equipment and specialist intervention in the surgical ICU. It can be safely performed by a surgical intensivist with experience in surgical tracheostomy.
format Online
Article
Text
id pubmed-6849057
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Korean Society of Critical Care Medicine
record_format MEDLINE/PubMed
spelling pubmed-68490572019-11-13 Feasibility of Percutaneous Dilatational Tracheostomy with a Light Source in the Surgical Intensive Care Unit Baek, Jong-Kwan Lee, Jung-Sun Kang, Minchang Choi, Nak-Jun Hong, Suk-Kyung Acute Crit Care Original Article BACKGROUND: Although percutaneous dilatational tracheostomy (PDT) under bronchoscopic guidance is feasible in the intensive care unit (ICU), it requires extensive equipment and specialists. The present study evaluated the feasibility of performing PDT with a light source in the surgical ICU. METHODS: The study involved a retrospective review of the outcomes of patients who underwent PDT with a light source performed by a surgery resident under the supervision of a surgical intensivist in the surgical ICU from October 2015 through September 2016. During the procedure, a light wand was inserted into the endotracheal tube after skin incision. Then, the light wand and the endotracheal tube were pulled out slightly, the passage of light through the airway was confirmed, and the relevant point was punctured. RESULTS: Fifty patients underwent PDT with a light source. The average procedural duration was 14.0 ± 7.0 minutes. There were no procedure-associated deaths. Intraoperative complications included minor bleeding in three patients (6%) and paratracheal placement of the tracheostomy tube in one patient (2%); these were immediately resolved by the surgical intensivist. Two patients required conversion to surgical tracheostomy because of the difficulty in light wand insertion into the endotracheal tube and a very narrow trachea, respectively. CONCLUSIONS: PDT with a light source can be performed without bronchoscopy and does not require expensive equipment and specialist intervention in the surgical ICU. It can be safely performed by a surgical intensivist with experience in surgical tracheostomy. Korean Society of Critical Care Medicine 2018-05 2018-04-26 /pmc/articles/PMC6849057/ /pubmed/31723868 http://dx.doi.org/10.4266/acc.2017.00563 Text en Copyright © 2018 The Korean Society of Critical Care Medicine This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Baek, Jong-Kwan
Lee, Jung-Sun
Kang, Minchang
Choi, Nak-Jun
Hong, Suk-Kyung
Feasibility of Percutaneous Dilatational Tracheostomy with a Light Source in the Surgical Intensive Care Unit
title Feasibility of Percutaneous Dilatational Tracheostomy with a Light Source in the Surgical Intensive Care Unit
title_full Feasibility of Percutaneous Dilatational Tracheostomy with a Light Source in the Surgical Intensive Care Unit
title_fullStr Feasibility of Percutaneous Dilatational Tracheostomy with a Light Source in the Surgical Intensive Care Unit
title_full_unstemmed Feasibility of Percutaneous Dilatational Tracheostomy with a Light Source in the Surgical Intensive Care Unit
title_short Feasibility of Percutaneous Dilatational Tracheostomy with a Light Source in the Surgical Intensive Care Unit
title_sort feasibility of percutaneous dilatational tracheostomy with a light source in the surgical intensive care unit
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6849057/
https://www.ncbi.nlm.nih.gov/pubmed/31723868
http://dx.doi.org/10.4266/acc.2017.00563
work_keys_str_mv AT baekjongkwan feasibilityofpercutaneousdilatationaltracheostomywithalightsourceinthesurgicalintensivecareunit
AT leejungsun feasibilityofpercutaneousdilatationaltracheostomywithalightsourceinthesurgicalintensivecareunit
AT kangminchang feasibilityofpercutaneousdilatationaltracheostomywithalightsourceinthesurgicalintensivecareunit
AT choinakjun feasibilityofpercutaneousdilatationaltracheostomywithalightsourceinthesurgicalintensivecareunit
AT hongsukkyung feasibilityofpercutaneousdilatationaltracheostomywithalightsourceinthesurgicalintensivecareunit