Feasibility of Percutaneous Dilatational Tracheostomy with a Light Source in the Surgical Intensive Care Unit
BACKGROUND: Although percutaneous dilatational tracheostomy (PDT) under bronchoscopic guidance is feasible in the intensive care unit (ICU), it requires extensive equipment and specialists. The present study evaluated the feasibility of performing PDT with a light source in the surgical ICU. METHODS...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Society of Critical Care Medicine
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6849057/ https://www.ncbi.nlm.nih.gov/pubmed/31723868 http://dx.doi.org/10.4266/acc.2017.00563 |
_version_ | 1783469129194274816 |
---|---|
author | Baek, Jong-Kwan Lee, Jung-Sun Kang, Minchang Choi, Nak-Jun Hong, Suk-Kyung |
author_facet | Baek, Jong-Kwan Lee, Jung-Sun Kang, Minchang Choi, Nak-Jun Hong, Suk-Kyung |
author_sort | Baek, Jong-Kwan |
collection | PubMed |
description | BACKGROUND: Although percutaneous dilatational tracheostomy (PDT) under bronchoscopic guidance is feasible in the intensive care unit (ICU), it requires extensive equipment and specialists. The present study evaluated the feasibility of performing PDT with a light source in the surgical ICU. METHODS: The study involved a retrospective review of the outcomes of patients who underwent PDT with a light source performed by a surgery resident under the supervision of a surgical intensivist in the surgical ICU from October 2015 through September 2016. During the procedure, a light wand was inserted into the endotracheal tube after skin incision. Then, the light wand and the endotracheal tube were pulled out slightly, the passage of light through the airway was confirmed, and the relevant point was punctured. RESULTS: Fifty patients underwent PDT with a light source. The average procedural duration was 14.0 ± 7.0 minutes. There were no procedure-associated deaths. Intraoperative complications included minor bleeding in three patients (6%) and paratracheal placement of the tracheostomy tube in one patient (2%); these were immediately resolved by the surgical intensivist. Two patients required conversion to surgical tracheostomy because of the difficulty in light wand insertion into the endotracheal tube and a very narrow trachea, respectively. CONCLUSIONS: PDT with a light source can be performed without bronchoscopy and does not require expensive equipment and specialist intervention in the surgical ICU. It can be safely performed by a surgical intensivist with experience in surgical tracheostomy. |
format | Online Article Text |
id | pubmed-6849057 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Korean Society of Critical Care Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-68490572019-11-13 Feasibility of Percutaneous Dilatational Tracheostomy with a Light Source in the Surgical Intensive Care Unit Baek, Jong-Kwan Lee, Jung-Sun Kang, Minchang Choi, Nak-Jun Hong, Suk-Kyung Acute Crit Care Original Article BACKGROUND: Although percutaneous dilatational tracheostomy (PDT) under bronchoscopic guidance is feasible in the intensive care unit (ICU), it requires extensive equipment and specialists. The present study evaluated the feasibility of performing PDT with a light source in the surgical ICU. METHODS: The study involved a retrospective review of the outcomes of patients who underwent PDT with a light source performed by a surgery resident under the supervision of a surgical intensivist in the surgical ICU from October 2015 through September 2016. During the procedure, a light wand was inserted into the endotracheal tube after skin incision. Then, the light wand and the endotracheal tube were pulled out slightly, the passage of light through the airway was confirmed, and the relevant point was punctured. RESULTS: Fifty patients underwent PDT with a light source. The average procedural duration was 14.0 ± 7.0 minutes. There were no procedure-associated deaths. Intraoperative complications included minor bleeding in three patients (6%) and paratracheal placement of the tracheostomy tube in one patient (2%); these were immediately resolved by the surgical intensivist. Two patients required conversion to surgical tracheostomy because of the difficulty in light wand insertion into the endotracheal tube and a very narrow trachea, respectively. CONCLUSIONS: PDT with a light source can be performed without bronchoscopy and does not require expensive equipment and specialist intervention in the surgical ICU. It can be safely performed by a surgical intensivist with experience in surgical tracheostomy. Korean Society of Critical Care Medicine 2018-05 2018-04-26 /pmc/articles/PMC6849057/ /pubmed/31723868 http://dx.doi.org/10.4266/acc.2017.00563 Text en Copyright © 2018 The Korean Society of Critical Care Medicine This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Baek, Jong-Kwan Lee, Jung-Sun Kang, Minchang Choi, Nak-Jun Hong, Suk-Kyung Feasibility of Percutaneous Dilatational Tracheostomy with a Light Source in the Surgical Intensive Care Unit |
title | Feasibility of Percutaneous Dilatational Tracheostomy with a Light Source in the Surgical Intensive Care Unit |
title_full | Feasibility of Percutaneous Dilatational Tracheostomy with a Light Source in the Surgical Intensive Care Unit |
title_fullStr | Feasibility of Percutaneous Dilatational Tracheostomy with a Light Source in the Surgical Intensive Care Unit |
title_full_unstemmed | Feasibility of Percutaneous Dilatational Tracheostomy with a Light Source in the Surgical Intensive Care Unit |
title_short | Feasibility of Percutaneous Dilatational Tracheostomy with a Light Source in the Surgical Intensive Care Unit |
title_sort | feasibility of percutaneous dilatational tracheostomy with a light source in the surgical intensive care unit |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6849057/ https://www.ncbi.nlm.nih.gov/pubmed/31723868 http://dx.doi.org/10.4266/acc.2017.00563 |
work_keys_str_mv | AT baekjongkwan feasibilityofpercutaneousdilatationaltracheostomywithalightsourceinthesurgicalintensivecareunit AT leejungsun feasibilityofpercutaneousdilatationaltracheostomywithalightsourceinthesurgicalintensivecareunit AT kangminchang feasibilityofpercutaneousdilatationaltracheostomywithalightsourceinthesurgicalintensivecareunit AT choinakjun feasibilityofpercutaneousdilatationaltracheostomywithalightsourceinthesurgicalintensivecareunit AT hongsukkyung feasibilityofpercutaneousdilatationaltracheostomywithalightsourceinthesurgicalintensivecareunit |