An unexpected cause of pericardial effusion
We present a case of pericardial effusion due to embolization of a fragment of an inferior vena cava (IVC) filter, with subsequent perforation of the right ventricle. This is a rare and unexpected cause of pericardial effusion. Fracture or embolization of IVC filters is a relatively uncommon complic...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6849906/ https://www.ncbi.nlm.nih.gov/pubmed/31724609 http://dx.doi.org/10.1016/j.jvsc.2015.03.005 |
_version_ | 1783469306622771200 |
---|---|
author | Moses, J.B. Brown, Ramon A. Miller, Kristen H. Creswell, Lawrence L. |
author_facet | Moses, J.B. Brown, Ramon A. Miller, Kristen H. Creswell, Lawrence L. |
author_sort | Moses, J.B. |
collection | PubMed |
description | We present a case of pericardial effusion due to embolization of a fragment of an inferior vena cava (IVC) filter, with subsequent perforation of the right ventricle. This is a rare and unexpected cause of pericardial effusion. Fracture or embolization of IVC filters is a relatively uncommon complication, but these events may have serious clinical implications. Although IVC filters are often placed with the intent of removal, the device in many patients is never removed. The long-term implications of IVC filter placement must be kept in mind when making decisions about device placement and subsequent removal. |
format | Online Article Text |
id | pubmed-6849906 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-68499062019-11-13 An unexpected cause of pericardial effusion Moses, J.B. Brown, Ramon A. Miller, Kristen H. Creswell, Lawrence L. J Vasc Surg Cases Article We present a case of pericardial effusion due to embolization of a fragment of an inferior vena cava (IVC) filter, with subsequent perforation of the right ventricle. This is a rare and unexpected cause of pericardial effusion. Fracture or embolization of IVC filters is a relatively uncommon complication, but these events may have serious clinical implications. Although IVC filters are often placed with the intent of removal, the device in many patients is never removed. The long-term implications of IVC filter placement must be kept in mind when making decisions about device placement and subsequent removal. Elsevier 2015-04-21 /pmc/articles/PMC6849906/ /pubmed/31724609 http://dx.doi.org/10.1016/j.jvsc.2015.03.005 Text en © 2015 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Article Moses, J.B. Brown, Ramon A. Miller, Kristen H. Creswell, Lawrence L. An unexpected cause of pericardial effusion |
title | An unexpected cause of pericardial effusion |
title_full | An unexpected cause of pericardial effusion |
title_fullStr | An unexpected cause of pericardial effusion |
title_full_unstemmed | An unexpected cause of pericardial effusion |
title_short | An unexpected cause of pericardial effusion |
title_sort | unexpected cause of pericardial effusion |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6849906/ https://www.ncbi.nlm.nih.gov/pubmed/31724609 http://dx.doi.org/10.1016/j.jvsc.2015.03.005 |
work_keys_str_mv | AT mosesjb anunexpectedcauseofpericardialeffusion AT brownramona anunexpectedcauseofpericardialeffusion AT millerkristenh anunexpectedcauseofpericardialeffusion AT creswelllawrencel anunexpectedcauseofpericardialeffusion AT mosesjb unexpectedcauseofpericardialeffusion AT brownramona unexpectedcauseofpericardialeffusion AT millerkristenh unexpectedcauseofpericardialeffusion AT creswelllawrencel unexpectedcauseofpericardialeffusion |