Cargando…

Extra-anatomic bypass with open-plugging stent graft for extensive dissected aortic aneurysm

Treatment for an extensively dissected aortic aneurysm is a surgical challenge. Open surgery using a left thoracotomy is promising but can be dangerous in patients with pulmonary comorbidity. We treated a 63-year-old man with chronic type B aortic dissection with aneurysmal change and ascending aort...

Descripción completa

Detalles Bibliográficos
Autores principales: Saito, Yoshiaki, Kowatari, Ryosuke, Minakawa, Masahito, Daitoku, Kazuyuki, Suzuki, Yasuyuki, Fukuda, Ikuo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6849969/
https://www.ncbi.nlm.nih.gov/pubmed/31724643
http://dx.doi.org/10.1016/j.jvsc.2014.10.002
_version_ 1783469315069050880
author Saito, Yoshiaki
Kowatari, Ryosuke
Minakawa, Masahito
Daitoku, Kazuyuki
Suzuki, Yasuyuki
Fukuda, Ikuo
author_facet Saito, Yoshiaki
Kowatari, Ryosuke
Minakawa, Masahito
Daitoku, Kazuyuki
Suzuki, Yasuyuki
Fukuda, Ikuo
author_sort Saito, Yoshiaki
collection PubMed
description Treatment for an extensively dissected aortic aneurysm is a surgical challenge. Open surgery using a left thoracotomy is promising but can be dangerous in patients with pulmonary comorbidity. We treated a 63-year-old man with chronic type B aortic dissection with aneurysmal change and ascending aortic dilation. The thoracoabdominal aorta was also dissected, dilated, and tapered; thus, a simple hybrid strategy was not possible, even with open fenestration. We performed ascending aortic replacement with reconstruction of the cervical vessels and extra-anatomic bypass from the ascending to descending aorta, with aneurysmal isolation. A stent graft was inserted at the true lumen of the residual aneurysm to reduce endopressure. Total thrombosis and reduction in size of the aneurysm was achieved, and the patient recovered well, without complications.
format Online
Article
Text
id pubmed-6849969
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-68499692019-11-13 Extra-anatomic bypass with open-plugging stent graft for extensive dissected aortic aneurysm Saito, Yoshiaki Kowatari, Ryosuke Minakawa, Masahito Daitoku, Kazuyuki Suzuki, Yasuyuki Fukuda, Ikuo J Vasc Surg Cases Article Treatment for an extensively dissected aortic aneurysm is a surgical challenge. Open surgery using a left thoracotomy is promising but can be dangerous in patients with pulmonary comorbidity. We treated a 63-year-old man with chronic type B aortic dissection with aneurysmal change and ascending aortic dilation. The thoracoabdominal aorta was also dissected, dilated, and tapered; thus, a simple hybrid strategy was not possible, even with open fenestration. We performed ascending aortic replacement with reconstruction of the cervical vessels and extra-anatomic bypass from the ascending to descending aorta, with aneurysmal isolation. A stent graft was inserted at the true lumen of the residual aneurysm to reduce endopressure. Total thrombosis and reduction in size of the aneurysm was achieved, and the patient recovered well, without complications. Elsevier 2015-03-16 /pmc/articles/PMC6849969/ /pubmed/31724643 http://dx.doi.org/10.1016/j.jvsc.2014.10.002 Text en © 2015 The Authors http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/3.0/).
spellingShingle Article
Saito, Yoshiaki
Kowatari, Ryosuke
Minakawa, Masahito
Daitoku, Kazuyuki
Suzuki, Yasuyuki
Fukuda, Ikuo
Extra-anatomic bypass with open-plugging stent graft for extensive dissected aortic aneurysm
title Extra-anatomic bypass with open-plugging stent graft for extensive dissected aortic aneurysm
title_full Extra-anatomic bypass with open-plugging stent graft for extensive dissected aortic aneurysm
title_fullStr Extra-anatomic bypass with open-plugging stent graft for extensive dissected aortic aneurysm
title_full_unstemmed Extra-anatomic bypass with open-plugging stent graft for extensive dissected aortic aneurysm
title_short Extra-anatomic bypass with open-plugging stent graft for extensive dissected aortic aneurysm
title_sort extra-anatomic bypass with open-plugging stent graft for extensive dissected aortic aneurysm
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6849969/
https://www.ncbi.nlm.nih.gov/pubmed/31724643
http://dx.doi.org/10.1016/j.jvsc.2014.10.002
work_keys_str_mv AT saitoyoshiaki extraanatomicbypasswithopenpluggingstentgraftforextensivedissectedaorticaneurysm
AT kowatariryosuke extraanatomicbypasswithopenpluggingstentgraftforextensivedissectedaorticaneurysm
AT minakawamasahito extraanatomicbypasswithopenpluggingstentgraftforextensivedissectedaorticaneurysm
AT daitokukazuyuki extraanatomicbypasswithopenpluggingstentgraftforextensivedissectedaorticaneurysm
AT suzukiyasuyuki extraanatomicbypasswithopenpluggingstentgraftforextensivedissectedaorticaneurysm
AT fukudaikuo extraanatomicbypasswithopenpluggingstentgraftforextensivedissectedaorticaneurysm