Cargando…

Moving system with action sport cameras: 3D kinematics of the walking and running in a large volume

Traditionally, motion analysis in clinical laboratories using optoelectronic systems (MOCAP) is performed in acquisition volumes of limited size. Given the complexity and cost of MOCAP in larger volumes, action sports cameras (ASC) represent an alternative approach in which the cameras move along wi...

Descripción completa

Detalles Bibliográficos
Autores principales: Bernardina, Gustavo R. D., Monnet, Tony, Cerveri, Pietro, Silvatti, Amanda P.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6850531/
https://www.ncbi.nlm.nih.gov/pubmed/31714919
http://dx.doi.org/10.1371/journal.pone.0224182
_version_ 1783469444910022656
author Bernardina, Gustavo R. D.
Monnet, Tony
Cerveri, Pietro
Silvatti, Amanda P.
author_facet Bernardina, Gustavo R. D.
Monnet, Tony
Cerveri, Pietro
Silvatti, Amanda P.
author_sort Bernardina, Gustavo R. D.
collection PubMed
description Traditionally, motion analysis in clinical laboratories using optoelectronic systems (MOCAP) is performed in acquisition volumes of limited size. Given the complexity and cost of MOCAP in larger volumes, action sports cameras (ASC) represent an alternative approach in which the cameras move along with the subject during the movement task. Thus, this study aims to compare ASC against a traditional MOCAP in the perspective of reconstructing walking and running movements in large spatial volumes, which extend over the common laboratory setup. The two systems, consisting of four cameras each, were closely mounted on a custom carrying structure endowed with wheels. Two different acquisition setups, namely steady and moving conditions, were taken into account. A devoted calibration procedure, using the same protocol for the two systems, enabled the reconstruction of surface markers, placed on voluntary subjects, during the two acquisition setups. The comparison was quantitatively expressed in terms of three-dimensional (3D) marker reconstruction and kinematic computation quality. The quality of the marker reconstruction quality was quantified by means of the mean absolute error (MAE) of inter-marker distance and two-stick angle. The kinematic computation quality was quantified by means of the measure of the knee angle reconstruction during walking and running trials. In order to evaluate the camera system and moving camera effects, we used a Wilcoxon rank sum test and a Kruskal Wallis test (post-hoc Tukey), respectively. The Spearman correlation coefficient (ρ) and the Wilcoxon rank sum test were applied to compare the kinematic data obtained by the two camera systems. We found small ASC MAE values (< 2.6mm and 1.3°), but they were significantly bigger than the MOCAP (< 0.7mm and 0.6°). However, for the human movement no significant differences were found between kinematic variables in walking and running acquisitions (p>0.05), and the motion patterns of the right-left knee angles between both systems were very similar (ρ>0.90, p<0.05). These results highlighted the promising results of a system that uses ASC based on the procedure of mobile cameras to follow the movement of the subject, allowing a less constrained movement in the direction in which the structure moves, compared to the traditional laboratory setup.
format Online
Article
Text
id pubmed-6850531
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-68505312019-11-22 Moving system with action sport cameras: 3D kinematics of the walking and running in a large volume Bernardina, Gustavo R. D. Monnet, Tony Cerveri, Pietro Silvatti, Amanda P. PLoS One Research Article Traditionally, motion analysis in clinical laboratories using optoelectronic systems (MOCAP) is performed in acquisition volumes of limited size. Given the complexity and cost of MOCAP in larger volumes, action sports cameras (ASC) represent an alternative approach in which the cameras move along with the subject during the movement task. Thus, this study aims to compare ASC against a traditional MOCAP in the perspective of reconstructing walking and running movements in large spatial volumes, which extend over the common laboratory setup. The two systems, consisting of four cameras each, were closely mounted on a custom carrying structure endowed with wheels. Two different acquisition setups, namely steady and moving conditions, were taken into account. A devoted calibration procedure, using the same protocol for the two systems, enabled the reconstruction of surface markers, placed on voluntary subjects, during the two acquisition setups. The comparison was quantitatively expressed in terms of three-dimensional (3D) marker reconstruction and kinematic computation quality. The quality of the marker reconstruction quality was quantified by means of the mean absolute error (MAE) of inter-marker distance and two-stick angle. The kinematic computation quality was quantified by means of the measure of the knee angle reconstruction during walking and running trials. In order to evaluate the camera system and moving camera effects, we used a Wilcoxon rank sum test and a Kruskal Wallis test (post-hoc Tukey), respectively. The Spearman correlation coefficient (ρ) and the Wilcoxon rank sum test were applied to compare the kinematic data obtained by the two camera systems. We found small ASC MAE values (< 2.6mm and 1.3°), but they were significantly bigger than the MOCAP (< 0.7mm and 0.6°). However, for the human movement no significant differences were found between kinematic variables in walking and running acquisitions (p>0.05), and the motion patterns of the right-left knee angles between both systems were very similar (ρ>0.90, p<0.05). These results highlighted the promising results of a system that uses ASC based on the procedure of mobile cameras to follow the movement of the subject, allowing a less constrained movement in the direction in which the structure moves, compared to the traditional laboratory setup. Public Library of Science 2019-11-12 /pmc/articles/PMC6850531/ /pubmed/31714919 http://dx.doi.org/10.1371/journal.pone.0224182 Text en © 2019 Bernardina et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Bernardina, Gustavo R. D.
Monnet, Tony
Cerveri, Pietro
Silvatti, Amanda P.
Moving system with action sport cameras: 3D kinematics of the walking and running in a large volume
title Moving system with action sport cameras: 3D kinematics of the walking and running in a large volume
title_full Moving system with action sport cameras: 3D kinematics of the walking and running in a large volume
title_fullStr Moving system with action sport cameras: 3D kinematics of the walking and running in a large volume
title_full_unstemmed Moving system with action sport cameras: 3D kinematics of the walking and running in a large volume
title_short Moving system with action sport cameras: 3D kinematics of the walking and running in a large volume
title_sort moving system with action sport cameras: 3d kinematics of the walking and running in a large volume
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6850531/
https://www.ncbi.nlm.nih.gov/pubmed/31714919
http://dx.doi.org/10.1371/journal.pone.0224182
work_keys_str_mv AT bernardinagustavord movingsystemwithactionsportcameras3dkinematicsofthewalkingandrunninginalargevolume
AT monnettony movingsystemwithactionsportcameras3dkinematicsofthewalkingandrunninginalargevolume
AT cerveripietro movingsystemwithactionsportcameras3dkinematicsofthewalkingandrunninginalargevolume
AT silvattiamandap movingsystemwithactionsportcameras3dkinematicsofthewalkingandrunninginalargevolume