Cargando…

Stereoelectroencephalography electrode placement: Detection of blood vessel conflicts

OBJECTIVE: Various forms of vascular imaging are performed to identify vessels that should be avoided during stereoelectroencephalography (SEEG) planning. Digital subtraction angiography (DSA) is the gold standard for intracranial vascular imaging. DSA is an invasive investigation, and a balance is...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Kuo, Vakharia, Vejay N., Sparks, Rachel, Rodionov, Roman, Vos, Sjoerd B., McEvoy, Andrew W., Miserocchi, Anna, Wang, Maode, Ourselin, Sebastien, Duncan, John S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6851756/
https://www.ncbi.nlm.nih.gov/pubmed/31329275
http://dx.doi.org/10.1111/epi.16294
_version_ 1783469679557214208
author Li, Kuo
Vakharia, Vejay N.
Sparks, Rachel
Rodionov, Roman
Vos, Sjoerd B.
McEvoy, Andrew W.
Miserocchi, Anna
Wang, Maode
Ourselin, Sebastien
Duncan, John S.
author_facet Li, Kuo
Vakharia, Vejay N.
Sparks, Rachel
Rodionov, Roman
Vos, Sjoerd B.
McEvoy, Andrew W.
Miserocchi, Anna
Wang, Maode
Ourselin, Sebastien
Duncan, John S.
author_sort Li, Kuo
collection PubMed
description OBJECTIVE: Various forms of vascular imaging are performed to identify vessels that should be avoided during stereoelectroencephalography (SEEG) planning. Digital subtraction angiography (DSA) is the gold standard for intracranial vascular imaging. DSA is an invasive investigation, and a balance is necessary to identify all clinically relevant vessels and not to visualize irrelevant vessels that may unnecessarily restrict electrode placement. We sought to estimate the size of vessels that are clinically significant for SEEG planning. METHODS: Thirty‐three consecutive patients who underwent 354 SEEG electrode implantations planned with computer‐assisted planning and DSA segmentation between 2016 and 2018 were identified from a prospectively maintained database. Intracranial positions of electrodes were segmented from postimplantation computed tomography scans. Each electrode was manually reviewed using “probe‐eye view” with the raw preoperative DSA images for vascular conflicts. The diameter of vessels and the location of conflicts were noted. Vessel conflicts identified on raw DSA images were cross‐referenced against other modalities to determine whether the conflict could have been detected. RESULTS: One hundred sixty‐six vessel conflicts were identified between electrodes and DSA‐identified vessels, with 0‐3 conflicts per electrode and a median of four conflicts per patient. The median diameter of conflicting vessels was 1.3 mm (interquartile range [IQR] = 1.0‐1.5 mm). The median depth of conflict was 31.0 mm (IQR = 14.3‐45.0 mm) from the cortical surface. The addition of sulcal models to DSA, magnetic resonance venography (MRV), and T1 + gadolinium images, as an exclusion zone during computer‐assisted planning, would have prevented the majority of vessel conflicts. We were unable to determine whether vessels were displaced or transected by the electrodes. SIGNIFICANCE: Vascular segmentation from DSA images was significantly more sensitive than T1 + gadolinium or MRV images. Electrode conflicts with vessels 1‐1.5 mm in size did not result in a radiologically detectable or clinically significant hemorrhage and could potentially be excluded from consideration during SEEG planning.
format Online
Article
Text
id pubmed-6851756
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-68517562019-11-18 Stereoelectroencephalography electrode placement: Detection of blood vessel conflicts Li, Kuo Vakharia, Vejay N. Sparks, Rachel Rodionov, Roman Vos, Sjoerd B. McEvoy, Andrew W. Miserocchi, Anna Wang, Maode Ourselin, Sebastien Duncan, John S. Epilepsia Full‐length Original Research OBJECTIVE: Various forms of vascular imaging are performed to identify vessels that should be avoided during stereoelectroencephalography (SEEG) planning. Digital subtraction angiography (DSA) is the gold standard for intracranial vascular imaging. DSA is an invasive investigation, and a balance is necessary to identify all clinically relevant vessels and not to visualize irrelevant vessels that may unnecessarily restrict electrode placement. We sought to estimate the size of vessels that are clinically significant for SEEG planning. METHODS: Thirty‐three consecutive patients who underwent 354 SEEG electrode implantations planned with computer‐assisted planning and DSA segmentation between 2016 and 2018 were identified from a prospectively maintained database. Intracranial positions of electrodes were segmented from postimplantation computed tomography scans. Each electrode was manually reviewed using “probe‐eye view” with the raw preoperative DSA images for vascular conflicts. The diameter of vessels and the location of conflicts were noted. Vessel conflicts identified on raw DSA images were cross‐referenced against other modalities to determine whether the conflict could have been detected. RESULTS: One hundred sixty‐six vessel conflicts were identified between electrodes and DSA‐identified vessels, with 0‐3 conflicts per electrode and a median of four conflicts per patient. The median diameter of conflicting vessels was 1.3 mm (interquartile range [IQR] = 1.0‐1.5 mm). The median depth of conflict was 31.0 mm (IQR = 14.3‐45.0 mm) from the cortical surface. The addition of sulcal models to DSA, magnetic resonance venography (MRV), and T1 + gadolinium images, as an exclusion zone during computer‐assisted planning, would have prevented the majority of vessel conflicts. We were unable to determine whether vessels were displaced or transected by the electrodes. SIGNIFICANCE: Vascular segmentation from DSA images was significantly more sensitive than T1 + gadolinium or MRV images. Electrode conflicts with vessels 1‐1.5 mm in size did not result in a radiologically detectable or clinically significant hemorrhage and could potentially be excluded from consideration during SEEG planning. John Wiley and Sons Inc. 2019-07-22 2019-09 /pmc/articles/PMC6851756/ /pubmed/31329275 http://dx.doi.org/10.1111/epi.16294 Text en © 2019 The Authors. Epilepsia published by Wiley Periodicals, Inc. on behalf of International League Against Epilepsy This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Full‐length Original Research
Li, Kuo
Vakharia, Vejay N.
Sparks, Rachel
Rodionov, Roman
Vos, Sjoerd B.
McEvoy, Andrew W.
Miserocchi, Anna
Wang, Maode
Ourselin, Sebastien
Duncan, John S.
Stereoelectroencephalography electrode placement: Detection of blood vessel conflicts
title Stereoelectroencephalography electrode placement: Detection of blood vessel conflicts
title_full Stereoelectroencephalography electrode placement: Detection of blood vessel conflicts
title_fullStr Stereoelectroencephalography electrode placement: Detection of blood vessel conflicts
title_full_unstemmed Stereoelectroencephalography electrode placement: Detection of blood vessel conflicts
title_short Stereoelectroencephalography electrode placement: Detection of blood vessel conflicts
title_sort stereoelectroencephalography electrode placement: detection of blood vessel conflicts
topic Full‐length Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6851756/
https://www.ncbi.nlm.nih.gov/pubmed/31329275
http://dx.doi.org/10.1111/epi.16294
work_keys_str_mv AT likuo stereoelectroencephalographyelectrodeplacementdetectionofbloodvesselconflicts
AT vakhariavejayn stereoelectroencephalographyelectrodeplacementdetectionofbloodvesselconflicts
AT sparksrachel stereoelectroencephalographyelectrodeplacementdetectionofbloodvesselconflicts
AT rodionovroman stereoelectroencephalographyelectrodeplacementdetectionofbloodvesselconflicts
AT vossjoerdb stereoelectroencephalographyelectrodeplacementdetectionofbloodvesselconflicts
AT mcevoyandreww stereoelectroencephalographyelectrodeplacementdetectionofbloodvesselconflicts
AT miserocchianna stereoelectroencephalographyelectrodeplacementdetectionofbloodvesselconflicts
AT wangmaode stereoelectroencephalographyelectrodeplacementdetectionofbloodvesselconflicts
AT ourselinsebastien stereoelectroencephalographyelectrodeplacementdetectionofbloodvesselconflicts
AT duncanjohns stereoelectroencephalographyelectrodeplacementdetectionofbloodvesselconflicts