The Practical Significance of Measurement Error in Pulmonary Function Testing Conducted in Research Settings
Conventional spirometry produces measurement error by using repeatability criteria (RC) to discard acceptable data and terminating tests early when RC are met. These practices also implicitly assume that there is no variation across maneuvers within each test. This has implications for air pollution...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6851780/ https://www.ncbi.nlm.nih.gov/pubmed/31158315 http://dx.doi.org/10.1111/risa.13315 |
_version_ | 1783469685010857984 |
---|---|
author | Belzer, Richard B. Lewis, R. Jeffrey |
author_facet | Belzer, Richard B. Lewis, R. Jeffrey |
author_sort | Belzer, Richard B. |
collection | PubMed |
description | Conventional spirometry produces measurement error by using repeatability criteria (RC) to discard acceptable data and terminating tests early when RC are met. These practices also implicitly assume that there is no variation across maneuvers within each test. This has implications for air pollution regulations that rely on pulmonary function tests to determine adverse effects or set standards. We perform a Monte Carlo simulation of 20,902 tests of forced expiratory volume in 1 second (FEV(1)), each with eight maneuvers, for an individual with empirically obtained, plausibly normal pulmonary function. Default coefficients of variation for inter‐ and intratest variability (3% and 6%, respectively) are employed. Measurement error is defined as the difference between results from the conventional protocol and an unconstrained, eight‐maneuver alternative. In the default model, average measurement error is shown to be ∼5%. The minimum difference necessary for statistical significance at p < 0.05 for a before/after comparison is shown to be 16%. Meanwhile, the U.S. Environmental Protection Agency has deemed single‐digit percentage decrements in FEV(1) sufficient to justify more stringent national ambient air quality standards. Sensitivity analysis reveals that results are insensitive to intertest variability but highly sensitive to intratest variability. Halving the latter to 3% reduces measurement error by 55%. Increasing it to 9% or 12% increases measurement error by 65% or 125%, respectively. Within‐day FEV(1) differences ≤5% among normal subjects are believed to be clinically insignificant. Therefore, many differences reported as statistically significant are likely to be artifactual. Reliable data are needed to estimate intratest variability for the general population, subpopulations of interest, and research samples. Sensitive subpopulations (e.g., chronic obstructive pulmonary disease or COPD patients, asthmatics, children) are likely to have higher intratest variability, making it more difficult to derive valid statistical inferences about differences observed after treatment or exposure. |
format | Online Article Text |
id | pubmed-6851780 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-68517802019-11-18 The Practical Significance of Measurement Error in Pulmonary Function Testing Conducted in Research Settings Belzer, Richard B. Lewis, R. Jeffrey Risk Anal Original Research Articles Conventional spirometry produces measurement error by using repeatability criteria (RC) to discard acceptable data and terminating tests early when RC are met. These practices also implicitly assume that there is no variation across maneuvers within each test. This has implications for air pollution regulations that rely on pulmonary function tests to determine adverse effects or set standards. We perform a Monte Carlo simulation of 20,902 tests of forced expiratory volume in 1 second (FEV(1)), each with eight maneuvers, for an individual with empirically obtained, plausibly normal pulmonary function. Default coefficients of variation for inter‐ and intratest variability (3% and 6%, respectively) are employed. Measurement error is defined as the difference between results from the conventional protocol and an unconstrained, eight‐maneuver alternative. In the default model, average measurement error is shown to be ∼5%. The minimum difference necessary for statistical significance at p < 0.05 for a before/after comparison is shown to be 16%. Meanwhile, the U.S. Environmental Protection Agency has deemed single‐digit percentage decrements in FEV(1) sufficient to justify more stringent national ambient air quality standards. Sensitivity analysis reveals that results are insensitive to intertest variability but highly sensitive to intratest variability. Halving the latter to 3% reduces measurement error by 55%. Increasing it to 9% or 12% increases measurement error by 65% or 125%, respectively. Within‐day FEV(1) differences ≤5% among normal subjects are believed to be clinically insignificant. Therefore, many differences reported as statistically significant are likely to be artifactual. Reliable data are needed to estimate intratest variability for the general population, subpopulations of interest, and research samples. Sensitive subpopulations (e.g., chronic obstructive pulmonary disease or COPD patients, asthmatics, children) are likely to have higher intratest variability, making it more difficult to derive valid statistical inferences about differences observed after treatment or exposure. John Wiley and Sons Inc. 2019-06-03 2019-10 /pmc/articles/PMC6851780/ /pubmed/31158315 http://dx.doi.org/10.1111/risa.13315 Text en © 2019 The Authors Risk Analysis published by Wiley Periodicals, Inc. on behalf of Society for Risk Analysis. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Research Articles Belzer, Richard B. Lewis, R. Jeffrey The Practical Significance of Measurement Error in Pulmonary Function Testing Conducted in Research Settings |
title | The Practical Significance of Measurement Error in Pulmonary Function Testing Conducted in Research Settings |
title_full | The Practical Significance of Measurement Error in Pulmonary Function Testing Conducted in Research Settings |
title_fullStr | The Practical Significance of Measurement Error in Pulmonary Function Testing Conducted in Research Settings |
title_full_unstemmed | The Practical Significance of Measurement Error in Pulmonary Function Testing Conducted in Research Settings |
title_short | The Practical Significance of Measurement Error in Pulmonary Function Testing Conducted in Research Settings |
title_sort | practical significance of measurement error in pulmonary function testing conducted in research settings |
topic | Original Research Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6851780/ https://www.ncbi.nlm.nih.gov/pubmed/31158315 http://dx.doi.org/10.1111/risa.13315 |
work_keys_str_mv | AT belzerrichardb thepracticalsignificanceofmeasurementerrorinpulmonaryfunctiontestingconductedinresearchsettings AT lewisrjeffrey thepracticalsignificanceofmeasurementerrorinpulmonaryfunctiontestingconductedinresearchsettings AT belzerrichardb practicalsignificanceofmeasurementerrorinpulmonaryfunctiontestingconductedinresearchsettings AT lewisrjeffrey practicalsignificanceofmeasurementerrorinpulmonaryfunctiontestingconductedinresearchsettings |