Cargando…
Improved consistency of bond-line thickness when conducting single lap-shear joint tests
This article details a method for improving the consistency of bond-line thickness during lap-shear sample preparation. This includes the schematic for a lap-shear sample test rig and consideration for controlled variation of the bond-line thickness for up to ten pairs of samples at a time. Concerns...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6854070/ https://www.ncbi.nlm.nih.gov/pubmed/31754605 http://dx.doi.org/10.1016/j.mex.2019.09.002 |
_version_ | 1783470164927315968 |
---|---|
author | Flanagan, Joe Byrne, Lorcan Mohan, Joseph Twomey, Barry Stanton, Kenneth T. |
author_facet | Flanagan, Joe Byrne, Lorcan Mohan, Joseph Twomey, Barry Stanton, Kenneth T. |
author_sort | Flanagan, Joe |
collection | PubMed |
description | This article details a method for improving the consistency of bond-line thickness during lap-shear sample preparation. This includes the schematic for a lap-shear sample test rig and consideration for controlled variation of the bond-line thickness for up to ten pairs of samples at a time. Concerns regarding the curing of the samples when held on a large heat reservoir are addressed through direct measurement of the bond-rig temperature in combination with the cure chamber temperature. Additionally, the application of a release coating to the bond-rig has been demonstrated to improve ease of sample removal for the bond-rig, minimizing potential damage to the lap-shear sample set before testing. The release coating provides a clean surface for subsequent sets of samples, ensuring an even surface and reducing cleaning and degradation of the machined geometries of the rig. Overall, the proposed bond-rig provides: • Increased bond-line uniformity; • Up to ten samples prepared in a batch; • Option to apply a release coating to improve usability and minimize cleaning. |
format | Online Article Text |
id | pubmed-6854070 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-68540702019-11-21 Improved consistency of bond-line thickness when conducting single lap-shear joint tests Flanagan, Joe Byrne, Lorcan Mohan, Joseph Twomey, Barry Stanton, Kenneth T. MethodsX Materials Science This article details a method for improving the consistency of bond-line thickness during lap-shear sample preparation. This includes the schematic for a lap-shear sample test rig and consideration for controlled variation of the bond-line thickness for up to ten pairs of samples at a time. Concerns regarding the curing of the samples when held on a large heat reservoir are addressed through direct measurement of the bond-rig temperature in combination with the cure chamber temperature. Additionally, the application of a release coating to the bond-rig has been demonstrated to improve ease of sample removal for the bond-rig, minimizing potential damage to the lap-shear sample set before testing. The release coating provides a clean surface for subsequent sets of samples, ensuring an even surface and reducing cleaning and degradation of the machined geometries of the rig. Overall, the proposed bond-rig provides: • Increased bond-line uniformity; • Up to ten samples prepared in a batch; • Option to apply a release coating to improve usability and minimize cleaning. Elsevier 2019-09-10 /pmc/articles/PMC6854070/ /pubmed/31754605 http://dx.doi.org/10.1016/j.mex.2019.09.002 Text en © 2019 The Authors http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Materials Science Flanagan, Joe Byrne, Lorcan Mohan, Joseph Twomey, Barry Stanton, Kenneth T. Improved consistency of bond-line thickness when conducting single lap-shear joint tests |
title | Improved consistency of bond-line thickness when conducting single lap-shear joint tests |
title_full | Improved consistency of bond-line thickness when conducting single lap-shear joint tests |
title_fullStr | Improved consistency of bond-line thickness when conducting single lap-shear joint tests |
title_full_unstemmed | Improved consistency of bond-line thickness when conducting single lap-shear joint tests |
title_short | Improved consistency of bond-line thickness when conducting single lap-shear joint tests |
title_sort | improved consistency of bond-line thickness when conducting single lap-shear joint tests |
topic | Materials Science |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6854070/ https://www.ncbi.nlm.nih.gov/pubmed/31754605 http://dx.doi.org/10.1016/j.mex.2019.09.002 |
work_keys_str_mv | AT flanaganjoe improvedconsistencyofbondlinethicknesswhenconductingsinglelapshearjointtests AT byrnelorcan improvedconsistencyofbondlinethicknesswhenconductingsinglelapshearjointtests AT mohanjoseph improvedconsistencyofbondlinethicknesswhenconductingsinglelapshearjointtests AT twomeybarry improvedconsistencyofbondlinethicknesswhenconductingsinglelapshearjointtests AT stantonkennetht improvedconsistencyofbondlinethicknesswhenconductingsinglelapshearjointtests |