Cargando…

New Circumpapillary Retinal Nerve Fiber Layer Thickness and Bruch's Membrane Opening-Minimum Rim Width Assessment in Nonglaucomatous Eyes with Large Discs

PURPOSE: To compare the new spectral-domain optical coherence tomography (SD-OCT) algorithm for measuring circumpapillary retinal nerve fiber layer (RNFL) thickness centered on Bruch's membrane opening (BMO), RNFL(BMO1), with the conventional circumpapillary RNFL thickness measurement centered...

Descripción completa

Detalles Bibliográficos
Autores principales: Bayraktar, Serife, Sultanova, Gulnar, Cebeci, Zafer, Altinkurt, Emre, Izgi, Belgin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6854252/
https://www.ncbi.nlm.nih.gov/pubmed/31772764
http://dx.doi.org/10.1155/2019/3431217
_version_ 1783470191262302208
author Bayraktar, Serife
Sultanova, Gulnar
Cebeci, Zafer
Altinkurt, Emre
Izgi, Belgin
author_facet Bayraktar, Serife
Sultanova, Gulnar
Cebeci, Zafer
Altinkurt, Emre
Izgi, Belgin
author_sort Bayraktar, Serife
collection PubMed
description PURPOSE: To compare the new spectral-domain optical coherence tomography (SD-OCT) algorithm for measuring circumpapillary retinal nerve fiber layer (RNFL) thickness centered on Bruch's membrane opening (BMO), RNFL(BMO1), with the conventional circumpapillary RNFL thickness measurement centered on the optic disc (RNFL(Dİ)), and assess the BMO-minimum rim width (BMO-MRW) in nonglaucomatous eyes with large discs. METHODS: This prospective, cross-sectional, observational study included a total of 91 eyes of 91 patients having nonglaucomatous eyes with large discs (Group 1) and 50 eyes of 50 healthy subjects (Group 2). The optic nerve head (ONH) parameters obtained by confocal scanning laser ophthalmoscopy (CSLO), peripapillary RNFL thickness, BMO area, and BMO-MRW were imaged with SD-OCT. RESULTS: The mean disc size was 3.06 ± 0.42 mm(2) (range, 2.61–4.68) in Group 1 and 1.95 ± 0.23 mm(2) (range, 1.6–2.43) in Group 2 (p=0.0001). The mean BMO area was 2.9 ± 0.58 mm(2) (range, 1.26–4.62) in Group 1 and 2.05 ± 0.31 mm(2) (range, 1.51–2.82) in Group 2 (p=0.0001). The difference between RNFL(Dİ and) RNFL(BMO1) measurements in Group 1 was stronger than in Group 2 because it was significant in all sectors in large discs. The mean global BMO-MRW thickness was significantly thinner in large discs; it was 252.95 ± 42.16 µ (range, 170–420) in Group 1 and 326.06 ± 73.39 µ (range, 210–440) in Group 2 (p=0.0001). There was a positive correlation between BMO-MRW thickness measurements and RNFL thickness parameters, both with RNFL(Dİ) and RNFL(BMO1,) in global and all optic nerve sectors except temporal quadrants with r = 0.257–0.431 (p ≤ 0.001–0.01) in Group 1. But in control group, Group 2, there was a weak correlation or no correlation between BMO-MRW thickness measurements and RNFL thickness parameters with r = −0.256–0.328 (p=0.797–0.02). CONCLUSION: The new circumpapillary RNFL scanning algorithm centered on BMO is better to assess the RNFL thickness and BMO-MRW in large discs for the early diagnosis of glaucoma.
format Online
Article
Text
id pubmed-6854252
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-68542522019-11-26 New Circumpapillary Retinal Nerve Fiber Layer Thickness and Bruch's Membrane Opening-Minimum Rim Width Assessment in Nonglaucomatous Eyes with Large Discs Bayraktar, Serife Sultanova, Gulnar Cebeci, Zafer Altinkurt, Emre Izgi, Belgin J Ophthalmol Research Article PURPOSE: To compare the new spectral-domain optical coherence tomography (SD-OCT) algorithm for measuring circumpapillary retinal nerve fiber layer (RNFL) thickness centered on Bruch's membrane opening (BMO), RNFL(BMO1), with the conventional circumpapillary RNFL thickness measurement centered on the optic disc (RNFL(Dİ)), and assess the BMO-minimum rim width (BMO-MRW) in nonglaucomatous eyes with large discs. METHODS: This prospective, cross-sectional, observational study included a total of 91 eyes of 91 patients having nonglaucomatous eyes with large discs (Group 1) and 50 eyes of 50 healthy subjects (Group 2). The optic nerve head (ONH) parameters obtained by confocal scanning laser ophthalmoscopy (CSLO), peripapillary RNFL thickness, BMO area, and BMO-MRW were imaged with SD-OCT. RESULTS: The mean disc size was 3.06 ± 0.42 mm(2) (range, 2.61–4.68) in Group 1 and 1.95 ± 0.23 mm(2) (range, 1.6–2.43) in Group 2 (p=0.0001). The mean BMO area was 2.9 ± 0.58 mm(2) (range, 1.26–4.62) in Group 1 and 2.05 ± 0.31 mm(2) (range, 1.51–2.82) in Group 2 (p=0.0001). The difference between RNFL(Dİ and) RNFL(BMO1) measurements in Group 1 was stronger than in Group 2 because it was significant in all sectors in large discs. The mean global BMO-MRW thickness was significantly thinner in large discs; it was 252.95 ± 42.16 µ (range, 170–420) in Group 1 and 326.06 ± 73.39 µ (range, 210–440) in Group 2 (p=0.0001). There was a positive correlation between BMO-MRW thickness measurements and RNFL thickness parameters, both with RNFL(Dİ) and RNFL(BMO1,) in global and all optic nerve sectors except temporal quadrants with r = 0.257–0.431 (p ≤ 0.001–0.01) in Group 1. But in control group, Group 2, there was a weak correlation or no correlation between BMO-MRW thickness measurements and RNFL thickness parameters with r = −0.256–0.328 (p=0.797–0.02). CONCLUSION: The new circumpapillary RNFL scanning algorithm centered on BMO is better to assess the RNFL thickness and BMO-MRW in large discs for the early diagnosis of glaucoma. Hindawi 2019-10-23 /pmc/articles/PMC6854252/ /pubmed/31772764 http://dx.doi.org/10.1155/2019/3431217 Text en Copyright © 2019 Serife Bayraktar et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Bayraktar, Serife
Sultanova, Gulnar
Cebeci, Zafer
Altinkurt, Emre
Izgi, Belgin
New Circumpapillary Retinal Nerve Fiber Layer Thickness and Bruch's Membrane Opening-Minimum Rim Width Assessment in Nonglaucomatous Eyes with Large Discs
title New Circumpapillary Retinal Nerve Fiber Layer Thickness and Bruch's Membrane Opening-Minimum Rim Width Assessment in Nonglaucomatous Eyes with Large Discs
title_full New Circumpapillary Retinal Nerve Fiber Layer Thickness and Bruch's Membrane Opening-Minimum Rim Width Assessment in Nonglaucomatous Eyes with Large Discs
title_fullStr New Circumpapillary Retinal Nerve Fiber Layer Thickness and Bruch's Membrane Opening-Minimum Rim Width Assessment in Nonglaucomatous Eyes with Large Discs
title_full_unstemmed New Circumpapillary Retinal Nerve Fiber Layer Thickness and Bruch's Membrane Opening-Minimum Rim Width Assessment in Nonglaucomatous Eyes with Large Discs
title_short New Circumpapillary Retinal Nerve Fiber Layer Thickness and Bruch's Membrane Opening-Minimum Rim Width Assessment in Nonglaucomatous Eyes with Large Discs
title_sort new circumpapillary retinal nerve fiber layer thickness and bruch's membrane opening-minimum rim width assessment in nonglaucomatous eyes with large discs
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6854252/
https://www.ncbi.nlm.nih.gov/pubmed/31772764
http://dx.doi.org/10.1155/2019/3431217
work_keys_str_mv AT bayraktarserife newcircumpapillaryretinalnervefiberlayerthicknessandbruchsmembraneopeningminimumrimwidthassessmentinnonglaucomatouseyeswithlargediscs
AT sultanovagulnar newcircumpapillaryretinalnervefiberlayerthicknessandbruchsmembraneopeningminimumrimwidthassessmentinnonglaucomatouseyeswithlargediscs
AT cebecizafer newcircumpapillaryretinalnervefiberlayerthicknessandbruchsmembraneopeningminimumrimwidthassessmentinnonglaucomatouseyeswithlargediscs
AT altinkurtemre newcircumpapillaryretinalnervefiberlayerthicknessandbruchsmembraneopeningminimumrimwidthassessmentinnonglaucomatouseyeswithlargediscs
AT izgibelgin newcircumpapillaryretinalnervefiberlayerthicknessandbruchsmembraneopeningminimumrimwidthassessmentinnonglaucomatouseyeswithlargediscs