Cargando…

The design of an individualized cylindrical vaginal applicator with oblique guide holes using 3D modeling and printing technologies

High-dose-rate brachytherapy for cervical cancer after subtotal hysterectomy using standardized applicators cannot achieve a good absorbed-dose coverage of the target volume in special tumor morphologies and topographies due to the steep dose gradient. The aim of this pictorial essay is to present a...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhao, Zhipeng, Tang, Xiaodi, Mao, Zhuang, Zhao, Hongfu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Termedia Publishing House 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6854860/
https://www.ncbi.nlm.nih.gov/pubmed/31749858
http://dx.doi.org/10.5114/jcb.2019.88441
_version_ 1783470298357563392
author Zhao, Zhipeng
Tang, Xiaodi
Mao, Zhuang
Zhao, Hongfu
author_facet Zhao, Zhipeng
Tang, Xiaodi
Mao, Zhuang
Zhao, Hongfu
author_sort Zhao, Zhipeng
collection PubMed
description High-dose-rate brachytherapy for cervical cancer after subtotal hysterectomy using standardized applicators cannot achieve a good absorbed-dose coverage of the target volume in special tumor morphologies and topographies due to the steep dose gradient. The aim of this pictorial essay is to present an individualized cylindrical vaginal applicator with oblique guide holes using 3D modeling and printing technologies used at the China-Japan Union Hospital of Jilin University for cervical cancer patients. We use images to describe the steps of this method.
format Online
Article
Text
id pubmed-6854860
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Termedia Publishing House
record_format MEDLINE/PubMed
spelling pubmed-68548602019-11-20 The design of an individualized cylindrical vaginal applicator with oblique guide holes using 3D modeling and printing technologies Zhao, Zhipeng Tang, Xiaodi Mao, Zhuang Zhao, Hongfu J Contemp Brachytherapy Case Report High-dose-rate brachytherapy for cervical cancer after subtotal hysterectomy using standardized applicators cannot achieve a good absorbed-dose coverage of the target volume in special tumor morphologies and topographies due to the steep dose gradient. The aim of this pictorial essay is to present an individualized cylindrical vaginal applicator with oblique guide holes using 3D modeling and printing technologies used at the China-Japan Union Hospital of Jilin University for cervical cancer patients. We use images to describe the steps of this method. Termedia Publishing House 2019-10-30 2019-10 /pmc/articles/PMC6854860/ /pubmed/31749858 http://dx.doi.org/10.5114/jcb.2019.88441 Text en Copyright: © 2019 Termedia Sp. z o. o. http://creativecommons.org/licenses/by-nc-sa/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0) License, allowing third parties to copy and redistribute the material in any medium or format and to remix, transform, and build upon the material, provided the original work is properly cited and states its license.
spellingShingle Case Report
Zhao, Zhipeng
Tang, Xiaodi
Mao, Zhuang
Zhao, Hongfu
The design of an individualized cylindrical vaginal applicator with oblique guide holes using 3D modeling and printing technologies
title The design of an individualized cylindrical vaginal applicator with oblique guide holes using 3D modeling and printing technologies
title_full The design of an individualized cylindrical vaginal applicator with oblique guide holes using 3D modeling and printing technologies
title_fullStr The design of an individualized cylindrical vaginal applicator with oblique guide holes using 3D modeling and printing technologies
title_full_unstemmed The design of an individualized cylindrical vaginal applicator with oblique guide holes using 3D modeling and printing technologies
title_short The design of an individualized cylindrical vaginal applicator with oblique guide holes using 3D modeling and printing technologies
title_sort design of an individualized cylindrical vaginal applicator with oblique guide holes using 3d modeling and printing technologies
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6854860/
https://www.ncbi.nlm.nih.gov/pubmed/31749858
http://dx.doi.org/10.5114/jcb.2019.88441
work_keys_str_mv AT zhaozhipeng thedesignofanindividualizedcylindricalvaginalapplicatorwithobliqueguideholesusing3dmodelingandprintingtechnologies
AT tangxiaodi thedesignofanindividualizedcylindricalvaginalapplicatorwithobliqueguideholesusing3dmodelingandprintingtechnologies
AT maozhuang thedesignofanindividualizedcylindricalvaginalapplicatorwithobliqueguideholesusing3dmodelingandprintingtechnologies
AT zhaohongfu thedesignofanindividualizedcylindricalvaginalapplicatorwithobliqueguideholesusing3dmodelingandprintingtechnologies
AT zhaozhipeng designofanindividualizedcylindricalvaginalapplicatorwithobliqueguideholesusing3dmodelingandprintingtechnologies
AT tangxiaodi designofanindividualizedcylindricalvaginalapplicatorwithobliqueguideholesusing3dmodelingandprintingtechnologies
AT maozhuang designofanindividualizedcylindricalvaginalapplicatorwithobliqueguideholesusing3dmodelingandprintingtechnologies
AT zhaohongfu designofanindividualizedcylindricalvaginalapplicatorwithobliqueguideholesusing3dmodelingandprintingtechnologies