The Feasibility and Histological Diagnostic Accuracy of Novel Menghini Needle (EUS Sonopsy CY™) for Endoscopic Ultrasound-Guided Fine-Needle Aspiration Biopsy of Solid Pancreatic Masses: A Prospective Crossover Study Comparing Standard Biopsy Needles

BACKGROUND AND OBJECTIVES: Recently, a 21G Menghini-type needle for EUS-guided fine-needle aspiration biopsy (EUS-FNAB) has been developed. The stylet of the EUS Sonopsy CY™ remains inside the needle during aspiration. Therefore, it is expected to obtain higher-quality histological core specimens wi...

Descripción completa

Detalles Bibliográficos
Autores principales: Igarashi, Ryo, Irisawa, Atsushi, Bhutani, Manoop S., Cazacu, Irina M., Shibukawa, Goro, Sato, Ai, Yamabe, Akane, Maki, Takumi, Yoshida, Yoshitsugu, Yamamoto, Shogo, Ikeda, Tsunehiko, Hojo, Hiroshi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6855019/
https://www.ncbi.nlm.nih.gov/pubmed/31781192
http://dx.doi.org/10.1155/2019/5810653
_version_ 1783470333710303232
author Igarashi, Ryo
Irisawa, Atsushi
Bhutani, Manoop S.
Cazacu, Irina M.
Shibukawa, Goro
Sato, Ai
Yamabe, Akane
Maki, Takumi
Yoshida, Yoshitsugu
Yamamoto, Shogo
Ikeda, Tsunehiko
Hojo, Hiroshi
author_facet Igarashi, Ryo
Irisawa, Atsushi
Bhutani, Manoop S.
Cazacu, Irina M.
Shibukawa, Goro
Sato, Ai
Yamabe, Akane
Maki, Takumi
Yoshida, Yoshitsugu
Yamamoto, Shogo
Ikeda, Tsunehiko
Hojo, Hiroshi
author_sort Igarashi, Ryo
collection PubMed
description BACKGROUND AND OBJECTIVES: Recently, a 21G Menghini-type needle for EUS-guided fine-needle aspiration biopsy (EUS-FNAB) has been developed. The stylet of the EUS Sonopsy CY™ remains inside the needle during aspiration. Therefore, it is expected to obtain higher-quality histological core specimens without crushing the material or blood contamination. The aim of this study is to evaluate the feasibility and diagnostic accuracy of EUS-FNAB of solid pancreatic masses with this new biopsy needle. METHODS: A total of 30 patients with solid pancreatic masses who underwent EUS-FNAB with two different types of needles, EUS Sonopsy™ and ProCore™, were included in a prospective, randomized, controlled, crossover study. All the pancreatic masses were punctured with the two needles and were randomized regarding the order of the needle to be used. The primary outcome was to compare the diagnostic accuracy and the rates of tissue acquisition of the two needles. RESULTS: The tissue acquisition rate was not significantly different between the EUS Sonopsy CY™ needle and the ProCore™ needle (78.6% vs. 82.1%, P = 1.00). The histological diagnostic accuracy was also similar between the two needles (73% vs. 80%, P = .63). There was also no difference regarding the accuracy of cytology alone and the combination of both histological and cytological assessments between the EUS Sonopsy CY™ needle and the ProCore™ needle (90% vs. 87%, P = 1.00 and 90% vs. 90%, P = 1.00, respectively). CONCLUSIONS: EUS Sonopsy CY™ is a reliable device for EUS-FNAB of solid pancreatic masses.
format Online
Article
Text
id pubmed-6855019
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-68550192019-11-28 The Feasibility and Histological Diagnostic Accuracy of Novel Menghini Needle (EUS Sonopsy CY™) for Endoscopic Ultrasound-Guided Fine-Needle Aspiration Biopsy of Solid Pancreatic Masses: A Prospective Crossover Study Comparing Standard Biopsy Needles Igarashi, Ryo Irisawa, Atsushi Bhutani, Manoop S. Cazacu, Irina M. Shibukawa, Goro Sato, Ai Yamabe, Akane Maki, Takumi Yoshida, Yoshitsugu Yamamoto, Shogo Ikeda, Tsunehiko Hojo, Hiroshi Gastroenterol Res Pract Research Article BACKGROUND AND OBJECTIVES: Recently, a 21G Menghini-type needle for EUS-guided fine-needle aspiration biopsy (EUS-FNAB) has been developed. The stylet of the EUS Sonopsy CY™ remains inside the needle during aspiration. Therefore, it is expected to obtain higher-quality histological core specimens without crushing the material or blood contamination. The aim of this study is to evaluate the feasibility and diagnostic accuracy of EUS-FNAB of solid pancreatic masses with this new biopsy needle. METHODS: A total of 30 patients with solid pancreatic masses who underwent EUS-FNAB with two different types of needles, EUS Sonopsy™ and ProCore™, were included in a prospective, randomized, controlled, crossover study. All the pancreatic masses were punctured with the two needles and were randomized regarding the order of the needle to be used. The primary outcome was to compare the diagnostic accuracy and the rates of tissue acquisition of the two needles. RESULTS: The tissue acquisition rate was not significantly different between the EUS Sonopsy CY™ needle and the ProCore™ needle (78.6% vs. 82.1%, P = 1.00). The histological diagnostic accuracy was also similar between the two needles (73% vs. 80%, P = .63). There was also no difference regarding the accuracy of cytology alone and the combination of both histological and cytological assessments between the EUS Sonopsy CY™ needle and the ProCore™ needle (90% vs. 87%, P = 1.00 and 90% vs. 90%, P = 1.00, respectively). CONCLUSIONS: EUS Sonopsy CY™ is a reliable device for EUS-FNAB of solid pancreatic masses. Hindawi 2019-10-21 /pmc/articles/PMC6855019/ /pubmed/31781192 http://dx.doi.org/10.1155/2019/5810653 Text en Copyright © 2019 Ryo Igarashi et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Igarashi, Ryo
Irisawa, Atsushi
Bhutani, Manoop S.
Cazacu, Irina M.
Shibukawa, Goro
Sato, Ai
Yamabe, Akane
Maki, Takumi
Yoshida, Yoshitsugu
Yamamoto, Shogo
Ikeda, Tsunehiko
Hojo, Hiroshi
The Feasibility and Histological Diagnostic Accuracy of Novel Menghini Needle (EUS Sonopsy CY™) for Endoscopic Ultrasound-Guided Fine-Needle Aspiration Biopsy of Solid Pancreatic Masses: A Prospective Crossover Study Comparing Standard Biopsy Needles
title The Feasibility and Histological Diagnostic Accuracy of Novel Menghini Needle (EUS Sonopsy CY™) for Endoscopic Ultrasound-Guided Fine-Needle Aspiration Biopsy of Solid Pancreatic Masses: A Prospective Crossover Study Comparing Standard Biopsy Needles
title_full The Feasibility and Histological Diagnostic Accuracy of Novel Menghini Needle (EUS Sonopsy CY™) for Endoscopic Ultrasound-Guided Fine-Needle Aspiration Biopsy of Solid Pancreatic Masses: A Prospective Crossover Study Comparing Standard Biopsy Needles
title_fullStr The Feasibility and Histological Diagnostic Accuracy of Novel Menghini Needle (EUS Sonopsy CY™) for Endoscopic Ultrasound-Guided Fine-Needle Aspiration Biopsy of Solid Pancreatic Masses: A Prospective Crossover Study Comparing Standard Biopsy Needles
title_full_unstemmed The Feasibility and Histological Diagnostic Accuracy of Novel Menghini Needle (EUS Sonopsy CY™) for Endoscopic Ultrasound-Guided Fine-Needle Aspiration Biopsy of Solid Pancreatic Masses: A Prospective Crossover Study Comparing Standard Biopsy Needles
title_short The Feasibility and Histological Diagnostic Accuracy of Novel Menghini Needle (EUS Sonopsy CY™) for Endoscopic Ultrasound-Guided Fine-Needle Aspiration Biopsy of Solid Pancreatic Masses: A Prospective Crossover Study Comparing Standard Biopsy Needles
title_sort feasibility and histological diagnostic accuracy of novel menghini needle (eus sonopsy cy™) for endoscopic ultrasound-guided fine-needle aspiration biopsy of solid pancreatic masses: a prospective crossover study comparing standard biopsy needles
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6855019/
https://www.ncbi.nlm.nih.gov/pubmed/31781192
http://dx.doi.org/10.1155/2019/5810653
work_keys_str_mv AT igarashiryo thefeasibilityandhistologicaldiagnosticaccuracyofnovelmenghinineedleeussonopsycyforendoscopicultrasoundguidedfineneedleaspirationbiopsyofsolidpancreaticmassesaprospectivecrossoverstudycomparingstandardbiopsyneedles
AT irisawaatsushi thefeasibilityandhistologicaldiagnosticaccuracyofnovelmenghinineedleeussonopsycyforendoscopicultrasoundguidedfineneedleaspirationbiopsyofsolidpancreaticmassesaprospectivecrossoverstudycomparingstandardbiopsyneedles
AT bhutanimanoops thefeasibilityandhistologicaldiagnosticaccuracyofnovelmenghinineedleeussonopsycyforendoscopicultrasoundguidedfineneedleaspirationbiopsyofsolidpancreaticmassesaprospectivecrossoverstudycomparingstandardbiopsyneedles
AT cazacuirinam thefeasibilityandhistologicaldiagnosticaccuracyofnovelmenghinineedleeussonopsycyforendoscopicultrasoundguidedfineneedleaspirationbiopsyofsolidpancreaticmassesaprospectivecrossoverstudycomparingstandardbiopsyneedles
AT shibukawagoro thefeasibilityandhistologicaldiagnosticaccuracyofnovelmenghinineedleeussonopsycyforendoscopicultrasoundguidedfineneedleaspirationbiopsyofsolidpancreaticmassesaprospectivecrossoverstudycomparingstandardbiopsyneedles
AT satoai thefeasibilityandhistologicaldiagnosticaccuracyofnovelmenghinineedleeussonopsycyforendoscopicultrasoundguidedfineneedleaspirationbiopsyofsolidpancreaticmassesaprospectivecrossoverstudycomparingstandardbiopsyneedles
AT yamabeakane thefeasibilityandhistologicaldiagnosticaccuracyofnovelmenghinineedleeussonopsycyforendoscopicultrasoundguidedfineneedleaspirationbiopsyofsolidpancreaticmassesaprospectivecrossoverstudycomparingstandardbiopsyneedles
AT makitakumi thefeasibilityandhistologicaldiagnosticaccuracyofnovelmenghinineedleeussonopsycyforendoscopicultrasoundguidedfineneedleaspirationbiopsyofsolidpancreaticmassesaprospectivecrossoverstudycomparingstandardbiopsyneedles
AT yoshidayoshitsugu thefeasibilityandhistologicaldiagnosticaccuracyofnovelmenghinineedleeussonopsycyforendoscopicultrasoundguidedfineneedleaspirationbiopsyofsolidpancreaticmassesaprospectivecrossoverstudycomparingstandardbiopsyneedles
AT yamamotoshogo thefeasibilityandhistologicaldiagnosticaccuracyofnovelmenghinineedleeussonopsycyforendoscopicultrasoundguidedfineneedleaspirationbiopsyofsolidpancreaticmassesaprospectivecrossoverstudycomparingstandardbiopsyneedles
AT ikedatsunehiko thefeasibilityandhistologicaldiagnosticaccuracyofnovelmenghinineedleeussonopsycyforendoscopicultrasoundguidedfineneedleaspirationbiopsyofsolidpancreaticmassesaprospectivecrossoverstudycomparingstandardbiopsyneedles
AT hojohiroshi thefeasibilityandhistologicaldiagnosticaccuracyofnovelmenghinineedleeussonopsycyforendoscopicultrasoundguidedfineneedleaspirationbiopsyofsolidpancreaticmassesaprospectivecrossoverstudycomparingstandardbiopsyneedles
AT igarashiryo feasibilityandhistologicaldiagnosticaccuracyofnovelmenghinineedleeussonopsycyforendoscopicultrasoundguidedfineneedleaspirationbiopsyofsolidpancreaticmassesaprospectivecrossoverstudycomparingstandardbiopsyneedles
AT irisawaatsushi feasibilityandhistologicaldiagnosticaccuracyofnovelmenghinineedleeussonopsycyforendoscopicultrasoundguidedfineneedleaspirationbiopsyofsolidpancreaticmassesaprospectivecrossoverstudycomparingstandardbiopsyneedles
AT bhutanimanoops feasibilityandhistologicaldiagnosticaccuracyofnovelmenghinineedleeussonopsycyforendoscopicultrasoundguidedfineneedleaspirationbiopsyofsolidpancreaticmassesaprospectivecrossoverstudycomparingstandardbiopsyneedles
AT cazacuirinam feasibilityandhistologicaldiagnosticaccuracyofnovelmenghinineedleeussonopsycyforendoscopicultrasoundguidedfineneedleaspirationbiopsyofsolidpancreaticmassesaprospectivecrossoverstudycomparingstandardbiopsyneedles
AT shibukawagoro feasibilityandhistologicaldiagnosticaccuracyofnovelmenghinineedleeussonopsycyforendoscopicultrasoundguidedfineneedleaspirationbiopsyofsolidpancreaticmassesaprospectivecrossoverstudycomparingstandardbiopsyneedles
AT satoai feasibilityandhistologicaldiagnosticaccuracyofnovelmenghinineedleeussonopsycyforendoscopicultrasoundguidedfineneedleaspirationbiopsyofsolidpancreaticmassesaprospectivecrossoverstudycomparingstandardbiopsyneedles
AT yamabeakane feasibilityandhistologicaldiagnosticaccuracyofnovelmenghinineedleeussonopsycyforendoscopicultrasoundguidedfineneedleaspirationbiopsyofsolidpancreaticmassesaprospectivecrossoverstudycomparingstandardbiopsyneedles
AT makitakumi feasibilityandhistologicaldiagnosticaccuracyofnovelmenghinineedleeussonopsycyforendoscopicultrasoundguidedfineneedleaspirationbiopsyofsolidpancreaticmassesaprospectivecrossoverstudycomparingstandardbiopsyneedles
AT yoshidayoshitsugu feasibilityandhistologicaldiagnosticaccuracyofnovelmenghinineedleeussonopsycyforendoscopicultrasoundguidedfineneedleaspirationbiopsyofsolidpancreaticmassesaprospectivecrossoverstudycomparingstandardbiopsyneedles
AT yamamotoshogo feasibilityandhistologicaldiagnosticaccuracyofnovelmenghinineedleeussonopsycyforendoscopicultrasoundguidedfineneedleaspirationbiopsyofsolidpancreaticmassesaprospectivecrossoverstudycomparingstandardbiopsyneedles
AT ikedatsunehiko feasibilityandhistologicaldiagnosticaccuracyofnovelmenghinineedleeussonopsycyforendoscopicultrasoundguidedfineneedleaspirationbiopsyofsolidpancreaticmassesaprospectivecrossoverstudycomparingstandardbiopsyneedles
AT hojohiroshi feasibilityandhistologicaldiagnosticaccuracyofnovelmenghinineedleeussonopsycyforendoscopicultrasoundguidedfineneedleaspirationbiopsyofsolidpancreaticmassesaprospectivecrossoverstudycomparingstandardbiopsyneedles