Possible Error in Reflection Pulse Oximeter Readings as a Result of Applied Pressure

Pulse oximetry is one of the most widely used techniques in modern medicine. In pulse oximetry, photoplethysmography (PPG) signals are measured at two different wavelengths and converted into the parameter Gamma, which is used to calculate the oxygen saturation of arterial blood. Although most pulse...

Descripción completa

Detalles Bibliográficos
Autores principales: Fine, Ilya, Kaminsky, Alexander
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6855088/
https://www.ncbi.nlm.nih.gov/pubmed/31781359
http://dx.doi.org/10.1155/2019/7293813
_version_ 1783470350060748800
author Fine, Ilya
Kaminsky, Alexander
author_facet Fine, Ilya
Kaminsky, Alexander
author_sort Fine, Ilya
collection PubMed
description Pulse oximetry is one of the most widely used techniques in modern medicine. In pulse oximetry, photoplethysmography (PPG) signals are measured at two different wavelengths and converted into the parameter Gamma, which is used to calculate the oxygen saturation of arterial blood. Although most pulse oximetry sensors are based on transmission geometry, the reflection mode is required for different form factors such as the forehead or wrists. In reflection oximetry, local pressure is applied to the measurement surface. We investigated the relationship between applied pressure and Gamma and found that for the reflection mode, Gamma tends to increase with increasing applied pressure. To explain this, we described the PPG signal in terms of two alternative models: a volumetric model and a Scattering-Driven Model (SDM). We assumed that the application of external pressure results in a decrease in local blood flow. We showed that only SDM correctly qualitatively describes Gamma as a function of the decrease in blood flow. We concluded that both described models coexist and that the relative influence of each depends on the measurement geometry and blood perfusion in the skin.
format Online
Article
Text
id pubmed-6855088
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-68550882019-11-28 Possible Error in Reflection Pulse Oximeter Readings as a Result of Applied Pressure Fine, Ilya Kaminsky, Alexander J Healthc Eng Research Article Pulse oximetry is one of the most widely used techniques in modern medicine. In pulse oximetry, photoplethysmography (PPG) signals are measured at two different wavelengths and converted into the parameter Gamma, which is used to calculate the oxygen saturation of arterial blood. Although most pulse oximetry sensors are based on transmission geometry, the reflection mode is required for different form factors such as the forehead or wrists. In reflection oximetry, local pressure is applied to the measurement surface. We investigated the relationship between applied pressure and Gamma and found that for the reflection mode, Gamma tends to increase with increasing applied pressure. To explain this, we described the PPG signal in terms of two alternative models: a volumetric model and a Scattering-Driven Model (SDM). We assumed that the application of external pressure results in a decrease in local blood flow. We showed that only SDM correctly qualitatively describes Gamma as a function of the decrease in blood flow. We concluded that both described models coexist and that the relative influence of each depends on the measurement geometry and blood perfusion in the skin. Hindawi 2019-10-24 /pmc/articles/PMC6855088/ /pubmed/31781359 http://dx.doi.org/10.1155/2019/7293813 Text en Copyright © 2019 Ilya Fine and Alexander Kaminsky. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Fine, Ilya
Kaminsky, Alexander
Possible Error in Reflection Pulse Oximeter Readings as a Result of Applied Pressure
title Possible Error in Reflection Pulse Oximeter Readings as a Result of Applied Pressure
title_full Possible Error in Reflection Pulse Oximeter Readings as a Result of Applied Pressure
title_fullStr Possible Error in Reflection Pulse Oximeter Readings as a Result of Applied Pressure
title_full_unstemmed Possible Error in Reflection Pulse Oximeter Readings as a Result of Applied Pressure
title_short Possible Error in Reflection Pulse Oximeter Readings as a Result of Applied Pressure
title_sort possible error in reflection pulse oximeter readings as a result of applied pressure
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6855088/
https://www.ncbi.nlm.nih.gov/pubmed/31781359
http://dx.doi.org/10.1155/2019/7293813
work_keys_str_mv AT fineilya possibleerrorinreflectionpulseoximeterreadingsasaresultofappliedpressure
AT kaminskyalexander possibleerrorinreflectionpulseoximeterreadingsasaresultofappliedpressure