First-in-Human Experience With Integration of a Hydrocephalus Shunt Device Within a Customized Cranial Implant
BACKGROUND: Implantable shunt devices are critical and life saving for hydrocephalus patients. However, these devices are fraught with high complication rates including scalp dehiscence, exposure, and extrusion. In fact, high shunt valve profiles are correlated with increased complications compared...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6855953/ https://www.ncbi.nlm.nih.gov/pubmed/30753624 http://dx.doi.org/10.1093/ons/opz003 |
_version_ | 1783470479731851264 |
---|---|
author | Gordon, Chad R Wolff, Amir Santiago, Gabriel F Liebman, Kenneth Veznedaroglu, Erol Vrionis, Frank D Huang, Judy Brem, Henry Luciano, Mark |
author_facet | Gordon, Chad R Wolff, Amir Santiago, Gabriel F Liebman, Kenneth Veznedaroglu, Erol Vrionis, Frank D Huang, Judy Brem, Henry Luciano, Mark |
author_sort | Gordon, Chad R |
collection | PubMed |
description | BACKGROUND: Implantable shunt devices are critical and life saving for hydrocephalus patients. However, these devices are fraught with high complication rates including scalp dehiscence, exposure, and extrusion. In fact, high shunt valve profiles are correlated with increased complications compared to those with lower profiles. As such, we sought a new method for integrating shunt valves for those challenging patients presenting with scalp-related complications. OBJECTIVE: To safely implant and integrate a hydrocephalus shunt valve device within a customized cranial implant, in an effort to limit its high-profile nature as a main contributor to shunt failure and scalp breakdown, and at the same time, improve patient satisfaction by preventing contour deformity. METHODS: A 64-yr-old male presented with an extruding hydrocephalus shunt valve and chronic, open scalp wound. The shunt valve was removed and temporary shunt externalization was performed. He received 2 wk of culture-directed antibiotics. Next, a contralateral craniectomy was performed allowing a new shunt valve system to be implanted within a low-profile, customized cranial implant. All efforts were made, at the patient's request, to decrease the high-profile nature of the shunt valve contributing to his most recent complication. RESULTS: First-in-human implantation was performed without complication. Postoperative shunt identification and programming was uncomplicated. The high-profile nature of the shunt valve was decreased by 87%. At 10 mo, the patient has experienced no complications and is extremely satisfied with his appearance. CONCLUSION: This first-in-human experience suggests that a high-profile hydrocephalus shunt device may be safely integrated within a customized cranial implant. |
format | Online Article Text |
id | pubmed-6855953 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-68559532019-11-20 First-in-Human Experience With Integration of a Hydrocephalus Shunt Device Within a Customized Cranial Implant Gordon, Chad R Wolff, Amir Santiago, Gabriel F Liebman, Kenneth Veznedaroglu, Erol Vrionis, Frank D Huang, Judy Brem, Henry Luciano, Mark Oper Neurosurg (Hagerstown) Concepts, Innovations and Techniques BACKGROUND: Implantable shunt devices are critical and life saving for hydrocephalus patients. However, these devices are fraught with high complication rates including scalp dehiscence, exposure, and extrusion. In fact, high shunt valve profiles are correlated with increased complications compared to those with lower profiles. As such, we sought a new method for integrating shunt valves for those challenging patients presenting with scalp-related complications. OBJECTIVE: To safely implant and integrate a hydrocephalus shunt valve device within a customized cranial implant, in an effort to limit its high-profile nature as a main contributor to shunt failure and scalp breakdown, and at the same time, improve patient satisfaction by preventing contour deformity. METHODS: A 64-yr-old male presented with an extruding hydrocephalus shunt valve and chronic, open scalp wound. The shunt valve was removed and temporary shunt externalization was performed. He received 2 wk of culture-directed antibiotics. Next, a contralateral craniectomy was performed allowing a new shunt valve system to be implanted within a low-profile, customized cranial implant. All efforts were made, at the patient's request, to decrease the high-profile nature of the shunt valve contributing to his most recent complication. RESULTS: First-in-human implantation was performed without complication. Postoperative shunt identification and programming was uncomplicated. The high-profile nature of the shunt valve was decreased by 87%. At 10 mo, the patient has experienced no complications and is extremely satisfied with his appearance. CONCLUSION: This first-in-human experience suggests that a high-profile hydrocephalus shunt device may be safely integrated within a customized cranial implant. Oxford University Press 2019-12 2019-02-07 /pmc/articles/PMC6855953/ /pubmed/30753624 http://dx.doi.org/10.1093/ons/opz003 Text en © Congress of Neurological Surgeons 2019. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs licence (http://creativecommons.org/licenses/by-nc-nd/4.0/), which permits non-commercial reproduction and distribution of the work, in any medium, provided the original work is not altered or transformed in any way, and that the work is properly cited. For commercial re-use, please contact journals.permissions@oup.com |
spellingShingle | Concepts, Innovations and Techniques Gordon, Chad R Wolff, Amir Santiago, Gabriel F Liebman, Kenneth Veznedaroglu, Erol Vrionis, Frank D Huang, Judy Brem, Henry Luciano, Mark First-in-Human Experience With Integration of a Hydrocephalus Shunt Device Within a Customized Cranial Implant |
title | First-in-Human Experience With Integration of a Hydrocephalus Shunt Device Within a Customized Cranial Implant |
title_full | First-in-Human Experience With Integration of a Hydrocephalus Shunt Device Within a Customized Cranial Implant |
title_fullStr | First-in-Human Experience With Integration of a Hydrocephalus Shunt Device Within a Customized Cranial Implant |
title_full_unstemmed | First-in-Human Experience With Integration of a Hydrocephalus Shunt Device Within a Customized Cranial Implant |
title_short | First-in-Human Experience With Integration of a Hydrocephalus Shunt Device Within a Customized Cranial Implant |
title_sort | first-in-human experience with integration of a hydrocephalus shunt device within a customized cranial implant |
topic | Concepts, Innovations and Techniques |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6855953/ https://www.ncbi.nlm.nih.gov/pubmed/30753624 http://dx.doi.org/10.1093/ons/opz003 |
work_keys_str_mv | AT gordonchadr firstinhumanexperiencewithintegrationofahydrocephalusshuntdevicewithinacustomizedcranialimplant AT wolffamir firstinhumanexperiencewithintegrationofahydrocephalusshuntdevicewithinacustomizedcranialimplant AT santiagogabrielf firstinhumanexperiencewithintegrationofahydrocephalusshuntdevicewithinacustomizedcranialimplant AT liebmankenneth firstinhumanexperiencewithintegrationofahydrocephalusshuntdevicewithinacustomizedcranialimplant AT veznedarogluerol firstinhumanexperiencewithintegrationofahydrocephalusshuntdevicewithinacustomizedcranialimplant AT vrionisfrankd firstinhumanexperiencewithintegrationofahydrocephalusshuntdevicewithinacustomizedcranialimplant AT huangjudy firstinhumanexperiencewithintegrationofahydrocephalusshuntdevicewithinacustomizedcranialimplant AT bremhenry firstinhumanexperiencewithintegrationofahydrocephalusshuntdevicewithinacustomizedcranialimplant AT lucianomark firstinhumanexperiencewithintegrationofahydrocephalusshuntdevicewithinacustomizedcranialimplant |