Cargando…
Contactless recording of sleep apnea and periodic leg movements by nocturnal 3-D-video and subsequent visual perceptive computing
Contactless measurements during the night by a 3-D-camera are less time-consuming in comparison to polysomnography because they do not require sophisticated wiring. However, it is not clear what might be the diagnostic benefit and accuracy of this technology. We investigated 59 persons simultaneousl...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6856090/ https://www.ncbi.nlm.nih.gov/pubmed/31727918 http://dx.doi.org/10.1038/s41598-019-53050-3 |
_version_ | 1783470505305571328 |
---|---|
author | Veauthier, Christian Ryczewski, Juliane Mansow-Model, Sebastian Otte, Karen Kayser, Bastian Glos, Martin Schöbel, Christoph Paul, Friedemann Brandt, Alexander U. Penzel, Thomas |
author_facet | Veauthier, Christian Ryczewski, Juliane Mansow-Model, Sebastian Otte, Karen Kayser, Bastian Glos, Martin Schöbel, Christoph Paul, Friedemann Brandt, Alexander U. Penzel, Thomas |
author_sort | Veauthier, Christian |
collection | PubMed |
description | Contactless measurements during the night by a 3-D-camera are less time-consuming in comparison to polysomnography because they do not require sophisticated wiring. However, it is not clear what might be the diagnostic benefit and accuracy of this technology. We investigated 59 persons simultaneously by polysomnography and 3-D-camera and visual perceptive computing (19 patients with restless legs syndrome (RLS), 21 patients with obstructive sleep apnea (OSA), and 19 healthy volunteers). There was a significant correlation between the apnea hypopnea index (AHI) measured by polysomnography and respiratory events measured with the 3-D-camera in OSA patients (r = 0.823; p < 0.001). The receiver operating characteristic curve yielded a sensitivity of 90% for OSA with a specificity of 71.4%. In RLS patients 72.8% of leg movements confirmed by polysomnography could be detected by 3-D-video and a significant moderate correlation was found between PLM measured by polysomnography and by the 3-D-camera (RLS: r = 0.654; p = 0.004). In total, 95.4% of the sleep epochs were correctly classified by the machine learning approach, but only 32.5% of awake epochs. Further studies should investigate, if this technique might be an alternative to home sleep testing in persons with an increased pre-test probability for OSA. |
format | Online Article Text |
id | pubmed-6856090 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-68560902019-11-19 Contactless recording of sleep apnea and periodic leg movements by nocturnal 3-D-video and subsequent visual perceptive computing Veauthier, Christian Ryczewski, Juliane Mansow-Model, Sebastian Otte, Karen Kayser, Bastian Glos, Martin Schöbel, Christoph Paul, Friedemann Brandt, Alexander U. Penzel, Thomas Sci Rep Article Contactless measurements during the night by a 3-D-camera are less time-consuming in comparison to polysomnography because they do not require sophisticated wiring. However, it is not clear what might be the diagnostic benefit and accuracy of this technology. We investigated 59 persons simultaneously by polysomnography and 3-D-camera and visual perceptive computing (19 patients with restless legs syndrome (RLS), 21 patients with obstructive sleep apnea (OSA), and 19 healthy volunteers). There was a significant correlation between the apnea hypopnea index (AHI) measured by polysomnography and respiratory events measured with the 3-D-camera in OSA patients (r = 0.823; p < 0.001). The receiver operating characteristic curve yielded a sensitivity of 90% for OSA with a specificity of 71.4%. In RLS patients 72.8% of leg movements confirmed by polysomnography could be detected by 3-D-video and a significant moderate correlation was found between PLM measured by polysomnography and by the 3-D-camera (RLS: r = 0.654; p = 0.004). In total, 95.4% of the sleep epochs were correctly classified by the machine learning approach, but only 32.5% of awake epochs. Further studies should investigate, if this technique might be an alternative to home sleep testing in persons with an increased pre-test probability for OSA. Nature Publishing Group UK 2019-11-14 /pmc/articles/PMC6856090/ /pubmed/31727918 http://dx.doi.org/10.1038/s41598-019-53050-3 Text en © The Author(s) 2019 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Article Veauthier, Christian Ryczewski, Juliane Mansow-Model, Sebastian Otte, Karen Kayser, Bastian Glos, Martin Schöbel, Christoph Paul, Friedemann Brandt, Alexander U. Penzel, Thomas Contactless recording of sleep apnea and periodic leg movements by nocturnal 3-D-video and subsequent visual perceptive computing |
title | Contactless recording of sleep apnea and periodic leg movements by nocturnal 3-D-video and subsequent visual perceptive computing |
title_full | Contactless recording of sleep apnea and periodic leg movements by nocturnal 3-D-video and subsequent visual perceptive computing |
title_fullStr | Contactless recording of sleep apnea and periodic leg movements by nocturnal 3-D-video and subsequent visual perceptive computing |
title_full_unstemmed | Contactless recording of sleep apnea and periodic leg movements by nocturnal 3-D-video and subsequent visual perceptive computing |
title_short | Contactless recording of sleep apnea and periodic leg movements by nocturnal 3-D-video and subsequent visual perceptive computing |
title_sort | contactless recording of sleep apnea and periodic leg movements by nocturnal 3-d-video and subsequent visual perceptive computing |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6856090/ https://www.ncbi.nlm.nih.gov/pubmed/31727918 http://dx.doi.org/10.1038/s41598-019-53050-3 |
work_keys_str_mv | AT veauthierchristian contactlessrecordingofsleepapneaandperiodiclegmovementsbynocturnal3dvideoandsubsequentvisualperceptivecomputing AT ryczewskijuliane contactlessrecordingofsleepapneaandperiodiclegmovementsbynocturnal3dvideoandsubsequentvisualperceptivecomputing AT mansowmodelsebastian contactlessrecordingofsleepapneaandperiodiclegmovementsbynocturnal3dvideoandsubsequentvisualperceptivecomputing AT ottekaren contactlessrecordingofsleepapneaandperiodiclegmovementsbynocturnal3dvideoandsubsequentvisualperceptivecomputing AT kayserbastian contactlessrecordingofsleepapneaandperiodiclegmovementsbynocturnal3dvideoandsubsequentvisualperceptivecomputing AT glosmartin contactlessrecordingofsleepapneaandperiodiclegmovementsbynocturnal3dvideoandsubsequentvisualperceptivecomputing AT schobelchristoph contactlessrecordingofsleepapneaandperiodiclegmovementsbynocturnal3dvideoandsubsequentvisualperceptivecomputing AT paulfriedemann contactlessrecordingofsleepapneaandperiodiclegmovementsbynocturnal3dvideoandsubsequentvisualperceptivecomputing AT brandtalexanderu contactlessrecordingofsleepapneaandperiodiclegmovementsbynocturnal3dvideoandsubsequentvisualperceptivecomputing AT penzelthomas contactlessrecordingofsleepapneaandperiodiclegmovementsbynocturnal3dvideoandsubsequentvisualperceptivecomputing |