Cargando…
Gradient diffusion antibiogram used directly on bronchial aspirates for a rapid diagnosis of ventilator-associated pneumonia
BACKGROUND: In patients with suspected ventilator-associated pneumonia, a rapid etiological diagnosis is crucial as incorrect or delayed treatment in the first few hours leads to a worse prognosis and a higher mortality rate. This study examines the efficacy of a rapid antibiogram on bronchial aspir...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6857332/ https://www.ncbi.nlm.nih.gov/pubmed/31807286 http://dx.doi.org/10.1186/s13756-019-0640-1 |
_version_ | 1783470748791209984 |
---|---|
author | Burillo, Almudena de Egea, Viviana Onori, Raffaella Martín-Rabadán, Pablo Cercenado, Emilia Jiménez-Navarro, Laura Muñoz, Patricia Bouza, Emilio |
author_facet | Burillo, Almudena de Egea, Viviana Onori, Raffaella Martín-Rabadán, Pablo Cercenado, Emilia Jiménez-Navarro, Laura Muñoz, Patricia Bouza, Emilio |
author_sort | Burillo, Almudena |
collection | PubMed |
description | BACKGROUND: In patients with suspected ventilator-associated pneumonia, a rapid etiological diagnosis is crucial as incorrect or delayed treatment in the first few hours leads to a worse prognosis and a higher mortality rate. This study examines the efficacy of a rapid antibiogram on bronchial aspirates in patients with suspected ventilator-associated pneumonia (VAP). METHODS: The direct gradient diffusion susceptibility testing method (GDM) on respiratory samples was compared with a standard broth microdilution method (BMD) after quantitative cultures in patients with suspicion of VAP. Samples were preselected by Gram staining (for good quality microbiological samples with a predominant single bacterial morphotype). The antibiotics tested were ceftazidime, ceftobiprole, ceftolozane-tazobactam, meropenem, doripenem, and tedizolid. RESULTS: Over a 16-month study period, 445 bronchial aspirate samples were selected from 1376 samples received at our laboratory from 672 adult patients. By direct plating on Mueller-Hinton agar, we recovered 504 (95.5%) of the 528 microorganisms identified by the standard semiquantitative method. Antimicrobial susceptibility testing by GDM was compared with the BMD method in 472 strains (216 Enterobacteriaceae, 138 P. aeruginosa and 118 S. aureus.) and 1652 individual microorganism-antimicrobial agent combinations. There was total agreement between both methods in 98% of combinations. The Kappa index between both techniques was excellent (over 80%). There was only one potential major error for P. aeruginosa susceptibility to ceftazidime. CONCLUSIONS: The six GDM strips directly placed on plated bronchial aspirates obtained from patients with a suspicion of VAP provided accurate and reliable susceptibility results within 24 h. |
format | Online Article Text |
id | pubmed-6857332 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-68573322019-12-05 Gradient diffusion antibiogram used directly on bronchial aspirates for a rapid diagnosis of ventilator-associated pneumonia Burillo, Almudena de Egea, Viviana Onori, Raffaella Martín-Rabadán, Pablo Cercenado, Emilia Jiménez-Navarro, Laura Muñoz, Patricia Bouza, Emilio Antimicrob Resist Infect Control Research BACKGROUND: In patients with suspected ventilator-associated pneumonia, a rapid etiological diagnosis is crucial as incorrect or delayed treatment in the first few hours leads to a worse prognosis and a higher mortality rate. This study examines the efficacy of a rapid antibiogram on bronchial aspirates in patients with suspected ventilator-associated pneumonia (VAP). METHODS: The direct gradient diffusion susceptibility testing method (GDM) on respiratory samples was compared with a standard broth microdilution method (BMD) after quantitative cultures in patients with suspicion of VAP. Samples were preselected by Gram staining (for good quality microbiological samples with a predominant single bacterial morphotype). The antibiotics tested were ceftazidime, ceftobiprole, ceftolozane-tazobactam, meropenem, doripenem, and tedizolid. RESULTS: Over a 16-month study period, 445 bronchial aspirate samples were selected from 1376 samples received at our laboratory from 672 adult patients. By direct plating on Mueller-Hinton agar, we recovered 504 (95.5%) of the 528 microorganisms identified by the standard semiquantitative method. Antimicrobial susceptibility testing by GDM was compared with the BMD method in 472 strains (216 Enterobacteriaceae, 138 P. aeruginosa and 118 S. aureus.) and 1652 individual microorganism-antimicrobial agent combinations. There was total agreement between both methods in 98% of combinations. The Kappa index between both techniques was excellent (over 80%). There was only one potential major error for P. aeruginosa susceptibility to ceftazidime. CONCLUSIONS: The six GDM strips directly placed on plated bronchial aspirates obtained from patients with a suspicion of VAP provided accurate and reliable susceptibility results within 24 h. BioMed Central 2019-11-14 /pmc/articles/PMC6857332/ /pubmed/31807286 http://dx.doi.org/10.1186/s13756-019-0640-1 Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Burillo, Almudena de Egea, Viviana Onori, Raffaella Martín-Rabadán, Pablo Cercenado, Emilia Jiménez-Navarro, Laura Muñoz, Patricia Bouza, Emilio Gradient diffusion antibiogram used directly on bronchial aspirates for a rapid diagnosis of ventilator-associated pneumonia |
title | Gradient diffusion antibiogram used directly on bronchial aspirates for a rapid diagnosis of ventilator-associated pneumonia |
title_full | Gradient diffusion antibiogram used directly on bronchial aspirates for a rapid diagnosis of ventilator-associated pneumonia |
title_fullStr | Gradient diffusion antibiogram used directly on bronchial aspirates for a rapid diagnosis of ventilator-associated pneumonia |
title_full_unstemmed | Gradient diffusion antibiogram used directly on bronchial aspirates for a rapid diagnosis of ventilator-associated pneumonia |
title_short | Gradient diffusion antibiogram used directly on bronchial aspirates for a rapid diagnosis of ventilator-associated pneumonia |
title_sort | gradient diffusion antibiogram used directly on bronchial aspirates for a rapid diagnosis of ventilator-associated pneumonia |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6857332/ https://www.ncbi.nlm.nih.gov/pubmed/31807286 http://dx.doi.org/10.1186/s13756-019-0640-1 |
work_keys_str_mv | AT burilloalmudena gradientdiffusionantibiogramuseddirectlyonbronchialaspiratesforarapiddiagnosisofventilatorassociatedpneumonia AT deegeaviviana gradientdiffusionantibiogramuseddirectlyonbronchialaspiratesforarapiddiagnosisofventilatorassociatedpneumonia AT onoriraffaella gradientdiffusionantibiogramuseddirectlyonbronchialaspiratesforarapiddiagnosisofventilatorassociatedpneumonia AT martinrabadanpablo gradientdiffusionantibiogramuseddirectlyonbronchialaspiratesforarapiddiagnosisofventilatorassociatedpneumonia AT cercenadoemilia gradientdiffusionantibiogramuseddirectlyonbronchialaspiratesforarapiddiagnosisofventilatorassociatedpneumonia AT jimeneznavarrolaura gradientdiffusionantibiogramuseddirectlyonbronchialaspiratesforarapiddiagnosisofventilatorassociatedpneumonia AT munozpatricia gradientdiffusionantibiogramuseddirectlyonbronchialaspiratesforarapiddiagnosisofventilatorassociatedpneumonia AT bouzaemilio gradientdiffusionantibiogramuseddirectlyonbronchialaspiratesforarapiddiagnosisofventilatorassociatedpneumonia |