Cargando…

The Validity, Reliability, Measurement Error, and Minimum Detectable Change of the 30‐Second Fast‐Paced Walk Test in Persons with Knee Osteoarthritis: A Novel Test of Short‐Distance Walking Ability

OBJECTIVE: To develop and establish the reliability, validity, measurement error, and minimum detectable change of a novel 30‐second fast‐paced walk test (30SFW) in persons with knee osteoarthritis (OA) that is easy to administer and can quantify walking performance in persons of all abilities. METH...

Descripción completa

Detalles Bibliográficos
Autores principales: Hoglund, Lisa T., Folkins, Eric, Pontiggia, Laura, Knapp, Michael W.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6858032/
https://www.ncbi.nlm.nih.gov/pubmed/31777804
http://dx.doi.org/10.1002/acr2.1040
_version_ 1783470872520032256
author Hoglund, Lisa T.
Folkins, Eric
Pontiggia, Laura
Knapp, Michael W.
author_facet Hoglund, Lisa T.
Folkins, Eric
Pontiggia, Laura
Knapp, Michael W.
author_sort Hoglund, Lisa T.
collection PubMed
description OBJECTIVE: To develop and establish the reliability, validity, measurement error, and minimum detectable change of a novel 30‐second fast‐paced walk test (30SFW) in persons with knee osteoarthritis (OA) that is easy to administer and can quantify walking performance in persons of all abilities. METHODS: Twenty females with symptomatic knee OA (mean age [SD] 58.30 [8.05] years) and 20 age‐ and sex‐matched asymptomatic controls (57.25 [8.71] years) participated in the study. Participants completed questionnaires of demographic and clinical data, the Knee Injury and Osteoarthritis Outcome Score (KOOS), and the 36‐item Short Form Health Survey (SF‐36) followed by 30SFW performance. Participants returned 2‐7 days later and performed the 30SFW again. RESULTS: The knee OA group reported function that was worse than controls (all KOOS subscales; P < 0.0001). The 30SFW intrarater and interrater reliability were excellent [ICC ((2,1)) = 0.95‐0.99]. Knee OA participants walked a shorter distance in the 30SFW than controls (mean [SD]: OA 44.4 m [9.5 m]; control 58.1 m [7.8 m]; P < 0.0001). Positive strong correlations were found between the 30SFW and the KOOS–Activity of Daily Living, SF‐36‐Physical Functioning, and SF‐36‐Physical Health Composite scores (P < 0.0001). A nonsignificant, weak correlation between 30SFW and SF‐36‐Mental Health scores was present (r = 0.32, P = 0.05). CONCLUSION: The 30SFW has excellent intrarater and interrater reliability. The 30SFW demonstrated excellent known groups, convergent, and discriminant validity as a measure of short‐distance walking ability in persons with knee OA. Clinicians and researchers should consider using the 30SFW to quantify walking ability in persons with knee OA and assess walking ability change.
format Online
Article
Text
id pubmed-6858032
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-68580322019-11-27 The Validity, Reliability, Measurement Error, and Minimum Detectable Change of the 30‐Second Fast‐Paced Walk Test in Persons with Knee Osteoarthritis: A Novel Test of Short‐Distance Walking Ability Hoglund, Lisa T. Folkins, Eric Pontiggia, Laura Knapp, Michael W. ACR Open Rheumatol Original Article OBJECTIVE: To develop and establish the reliability, validity, measurement error, and minimum detectable change of a novel 30‐second fast‐paced walk test (30SFW) in persons with knee osteoarthritis (OA) that is easy to administer and can quantify walking performance in persons of all abilities. METHODS: Twenty females with symptomatic knee OA (mean age [SD] 58.30 [8.05] years) and 20 age‐ and sex‐matched asymptomatic controls (57.25 [8.71] years) participated in the study. Participants completed questionnaires of demographic and clinical data, the Knee Injury and Osteoarthritis Outcome Score (KOOS), and the 36‐item Short Form Health Survey (SF‐36) followed by 30SFW performance. Participants returned 2‐7 days later and performed the 30SFW again. RESULTS: The knee OA group reported function that was worse than controls (all KOOS subscales; P < 0.0001). The 30SFW intrarater and interrater reliability were excellent [ICC ((2,1)) = 0.95‐0.99]. Knee OA participants walked a shorter distance in the 30SFW than controls (mean [SD]: OA 44.4 m [9.5 m]; control 58.1 m [7.8 m]; P < 0.0001). Positive strong correlations were found between the 30SFW and the KOOS–Activity of Daily Living, SF‐36‐Physical Functioning, and SF‐36‐Physical Health Composite scores (P < 0.0001). A nonsignificant, weak correlation between 30SFW and SF‐36‐Mental Health scores was present (r = 0.32, P = 0.05). CONCLUSION: The 30SFW has excellent intrarater and interrater reliability. The 30SFW demonstrated excellent known groups, convergent, and discriminant validity as a measure of short‐distance walking ability in persons with knee OA. Clinicians and researchers should consider using the 30SFW to quantify walking ability in persons with knee OA and assess walking ability change. John Wiley and Sons Inc. 2019-06-06 /pmc/articles/PMC6858032/ /pubmed/31777804 http://dx.doi.org/10.1002/acr2.1040 Text en © 2019 The Authors. ACR Open Rheumatology published by Wiley Periodicals, Inc. on behalf of American College of Rheumatology. This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
spellingShingle Original Article
Hoglund, Lisa T.
Folkins, Eric
Pontiggia, Laura
Knapp, Michael W.
The Validity, Reliability, Measurement Error, and Minimum Detectable Change of the 30‐Second Fast‐Paced Walk Test in Persons with Knee Osteoarthritis: A Novel Test of Short‐Distance Walking Ability
title The Validity, Reliability, Measurement Error, and Minimum Detectable Change of the 30‐Second Fast‐Paced Walk Test in Persons with Knee Osteoarthritis: A Novel Test of Short‐Distance Walking Ability
title_full The Validity, Reliability, Measurement Error, and Minimum Detectable Change of the 30‐Second Fast‐Paced Walk Test in Persons with Knee Osteoarthritis: A Novel Test of Short‐Distance Walking Ability
title_fullStr The Validity, Reliability, Measurement Error, and Minimum Detectable Change of the 30‐Second Fast‐Paced Walk Test in Persons with Knee Osteoarthritis: A Novel Test of Short‐Distance Walking Ability
title_full_unstemmed The Validity, Reliability, Measurement Error, and Minimum Detectable Change of the 30‐Second Fast‐Paced Walk Test in Persons with Knee Osteoarthritis: A Novel Test of Short‐Distance Walking Ability
title_short The Validity, Reliability, Measurement Error, and Minimum Detectable Change of the 30‐Second Fast‐Paced Walk Test in Persons with Knee Osteoarthritis: A Novel Test of Short‐Distance Walking Ability
title_sort validity, reliability, measurement error, and minimum detectable change of the 30‐second fast‐paced walk test in persons with knee osteoarthritis: a novel test of short‐distance walking ability
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6858032/
https://www.ncbi.nlm.nih.gov/pubmed/31777804
http://dx.doi.org/10.1002/acr2.1040
work_keys_str_mv AT hoglundlisat thevalidityreliabilitymeasurementerrorandminimumdetectablechangeofthe30secondfastpacedwalktestinpersonswithkneeosteoarthritisanoveltestofshortdistancewalkingability
AT folkinseric thevalidityreliabilitymeasurementerrorandminimumdetectablechangeofthe30secondfastpacedwalktestinpersonswithkneeosteoarthritisanoveltestofshortdistancewalkingability
AT pontiggialaura thevalidityreliabilitymeasurementerrorandminimumdetectablechangeofthe30secondfastpacedwalktestinpersonswithkneeosteoarthritisanoveltestofshortdistancewalkingability
AT knappmichaelw thevalidityreliabilitymeasurementerrorandminimumdetectablechangeofthe30secondfastpacedwalktestinpersonswithkneeosteoarthritisanoveltestofshortdistancewalkingability
AT hoglundlisat validityreliabilitymeasurementerrorandminimumdetectablechangeofthe30secondfastpacedwalktestinpersonswithkneeosteoarthritisanoveltestofshortdistancewalkingability
AT folkinseric validityreliabilitymeasurementerrorandminimumdetectablechangeofthe30secondfastpacedwalktestinpersonswithkneeosteoarthritisanoveltestofshortdistancewalkingability
AT pontiggialaura validityreliabilitymeasurementerrorandminimumdetectablechangeofthe30secondfastpacedwalktestinpersonswithkneeosteoarthritisanoveltestofshortdistancewalkingability
AT knappmichaelw validityreliabilitymeasurementerrorandminimumdetectablechangeofthe30secondfastpacedwalktestinpersonswithkneeosteoarthritisanoveltestofshortdistancewalkingability