Cargando…
Accelerometery as a measure of modifiable physical activity in high-risk elderly preoperative patients: a prospective observational pilot study
OBJECTIVES: To use wrist-worn accelerometers (Axivity AX3) to establish normative physical activity (PA) and acceptability data for the high-risk elderly preoperative population, to assess whether PA could be modified by a prehabilitation intervention as part of routine care, to assess any correlati...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BMJ Publishing Group
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6858105/ https://www.ncbi.nlm.nih.gov/pubmed/31685513 http://dx.doi.org/10.1136/bmjopen-2019-032346 |
_version_ | 1783470882464727040 |
---|---|
author | Grimes, Lisa Outtrim, Joanne G Griffin, Simon J Ercole, Ari |
author_facet | Grimes, Lisa Outtrim, Joanne G Griffin, Simon J Ercole, Ari |
author_sort | Grimes, Lisa |
collection | PubMed |
description | OBJECTIVES: To use wrist-worn accelerometers (Axivity AX3) to establish normative physical activity (PA) and acceptability data for the high-risk elderly preoperative population, to assess whether PA could be modified by a prehabilitation intervention as part of routine care, to assess any correlation between accelerometer-measured PA and self-reported PA and to assess the acceptability of wearing wrist-worn accelerometers in this population. STUDY DESIGN: Prospective, observational, pilot study. SETTING: Single National Health Service Hospital. PARTICIPANTS: Frail patients≥65 years awaiting major surgery referred to a multidisciplinary preoperative clinic at which they received a routine intervention aimed at improving their PA. 35 patients were recruited. Average age 79.9 years (SD=5.6). PRIMARY OUTCOMES: Normative PA data measured as a mean daily Euclidean norm minus one (ENMO) in milli-gravitational units (mg). SECONDARY OUTCOMES: Measure PA levels (mg) following a routine preoperative intervention. Determine correlation between patient-reported PA (measured using the Physical Activity Scale for the Elderly) and accelerometer-measured PA (mg). Assess acceptability of wearing a wrist-worn accelerometer measured using Visual Analogue Scale (VAS) questionnaire and device wear time (hours). RESULTS: Median baseline daily PA was 14.3 mg (IQR 9.75–22.04) with an improvement in PA detected following the intervention (median ENMO post intervention 20.91 mg (IQR 14.83–27.53), p=0.022). There was no significant correlation between accelerometer-measured and self-reported PA (baseline ρ=0.162 (p=0.4), post intervention ρ=−0.144 (p=0.5)). We found high acceptability ratings (median score of 10/10 on VAS, IQR 8–10) and wear-time compliance (163.2 hours (IQR 150–167.5) preintervention and 166.1 hours (IQR 162.5–167) post intervention). CONCLUSIONS: Accelerometery is acceptable to this population and increases in PA levels measured following an unoptimised routine clinical intervention which indicates that health behavioural change interventions may be successful during the preoperative period. Accelerometers may therefore be a useful tool to design and validate interventions for improving PA in this setting. TRIAL REGISTRATION NUMBER: NCT03737903. |
format | Online Article Text |
id | pubmed-6858105 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | BMJ Publishing Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-68581052019-12-03 Accelerometery as a measure of modifiable physical activity in high-risk elderly preoperative patients: a prospective observational pilot study Grimes, Lisa Outtrim, Joanne G Griffin, Simon J Ercole, Ari BMJ Open Anaesthesia OBJECTIVES: To use wrist-worn accelerometers (Axivity AX3) to establish normative physical activity (PA) and acceptability data for the high-risk elderly preoperative population, to assess whether PA could be modified by a prehabilitation intervention as part of routine care, to assess any correlation between accelerometer-measured PA and self-reported PA and to assess the acceptability of wearing wrist-worn accelerometers in this population. STUDY DESIGN: Prospective, observational, pilot study. SETTING: Single National Health Service Hospital. PARTICIPANTS: Frail patients≥65 years awaiting major surgery referred to a multidisciplinary preoperative clinic at which they received a routine intervention aimed at improving their PA. 35 patients were recruited. Average age 79.9 years (SD=5.6). PRIMARY OUTCOMES: Normative PA data measured as a mean daily Euclidean norm minus one (ENMO) in milli-gravitational units (mg). SECONDARY OUTCOMES: Measure PA levels (mg) following a routine preoperative intervention. Determine correlation between patient-reported PA (measured using the Physical Activity Scale for the Elderly) and accelerometer-measured PA (mg). Assess acceptability of wearing a wrist-worn accelerometer measured using Visual Analogue Scale (VAS) questionnaire and device wear time (hours). RESULTS: Median baseline daily PA was 14.3 mg (IQR 9.75–22.04) with an improvement in PA detected following the intervention (median ENMO post intervention 20.91 mg (IQR 14.83–27.53), p=0.022). There was no significant correlation between accelerometer-measured and self-reported PA (baseline ρ=0.162 (p=0.4), post intervention ρ=−0.144 (p=0.5)). We found high acceptability ratings (median score of 10/10 on VAS, IQR 8–10) and wear-time compliance (163.2 hours (IQR 150–167.5) preintervention and 166.1 hours (IQR 162.5–167) post intervention). CONCLUSIONS: Accelerometery is acceptable to this population and increases in PA levels measured following an unoptimised routine clinical intervention which indicates that health behavioural change interventions may be successful during the preoperative period. Accelerometers may therefore be a useful tool to design and validate interventions for improving PA in this setting. TRIAL REGISTRATION NUMBER: NCT03737903. BMJ Publishing Group 2019-11-03 /pmc/articles/PMC6858105/ /pubmed/31685513 http://dx.doi.org/10.1136/bmjopen-2019-032346 Text en © Author(s) (or their employer(s)) 2019. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ. This is an open access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited, appropriate credit is given, any changes made indicated, and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/. |
spellingShingle | Anaesthesia Grimes, Lisa Outtrim, Joanne G Griffin, Simon J Ercole, Ari Accelerometery as a measure of modifiable physical activity in high-risk elderly preoperative patients: a prospective observational pilot study |
title | Accelerometery as a measure of modifiable physical activity in high-risk elderly preoperative patients: a prospective observational pilot study |
title_full | Accelerometery as a measure of modifiable physical activity in high-risk elderly preoperative patients: a prospective observational pilot study |
title_fullStr | Accelerometery as a measure of modifiable physical activity in high-risk elderly preoperative patients: a prospective observational pilot study |
title_full_unstemmed | Accelerometery as a measure of modifiable physical activity in high-risk elderly preoperative patients: a prospective observational pilot study |
title_short | Accelerometery as a measure of modifiable physical activity in high-risk elderly preoperative patients: a prospective observational pilot study |
title_sort | accelerometery as a measure of modifiable physical activity in high-risk elderly preoperative patients: a prospective observational pilot study |
topic | Anaesthesia |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6858105/ https://www.ncbi.nlm.nih.gov/pubmed/31685513 http://dx.doi.org/10.1136/bmjopen-2019-032346 |
work_keys_str_mv | AT grimeslisa accelerometeryasameasureofmodifiablephysicalactivityinhighriskelderlypreoperativepatientsaprospectiveobservationalpilotstudy AT outtrimjoanneg accelerometeryasameasureofmodifiablephysicalactivityinhighriskelderlypreoperativepatientsaprospectiveobservationalpilotstudy AT griffinsimonj accelerometeryasameasureofmodifiablephysicalactivityinhighriskelderlypreoperativepatientsaprospectiveobservationalpilotstudy AT ercoleari accelerometeryasameasureofmodifiablephysicalactivityinhighriskelderlypreoperativepatientsaprospectiveobservationalpilotstudy |