Variation in use and outcomes related to midline catheters: results from a multicentre pilot study
BACKGROUND: While midline vascular catheters are gaining popularity in clinical practice, patterns of use and outcomes related to these devices are not well known. METHODS: Trained abstractors collected data from medical records of hospitalised patients who received midline catheters in 12 hospitals...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BMJ Publishing Group
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6860966/ https://www.ncbi.nlm.nih.gov/pubmed/30886119 http://dx.doi.org/10.1136/bmjqs-2018-008554 |
_version_ | 1783471257306529792 |
---|---|
author | Chopra, Vineet Kaatz, Scott Swaminathan, Lakshmi Boldenow, Tanya Snyder, Ashley Burris, Rachel Bernstein, Steve J Flanders, Scott |
author_facet | Chopra, Vineet Kaatz, Scott Swaminathan, Lakshmi Boldenow, Tanya Snyder, Ashley Burris, Rachel Bernstein, Steve J Flanders, Scott |
author_sort | Chopra, Vineet |
collection | PubMed |
description | BACKGROUND: While midline vascular catheters are gaining popularity in clinical practice, patterns of use and outcomes related to these devices are not well known. METHODS: Trained abstractors collected data from medical records of hospitalised patients who received midline catheters in 12 hospitals. Device characteristics, patterns of use and outcomes were assessed at device removal or at 30 days. Rates of major (upper-extremity deep vein thrombosis [DVT], bloodstream infection [BSI] and catheter occlusion) and minor complications were assessed. χ(2) tests were used to examine differences in rates of complication by number of lumens, reasons for catheter removal l, and hospital-level differences in rates of midline use. RESULTS: Complete data on 1161 midlines representing 5%–72% of all midlines placed in participating hospitals between 1 January 2017 and 1 March 2018 were available. Most (70.8%) midlines were placed in general ward settings for difficult intravenous access (61.4%). The median dwell time of midlines across hospitals was 6 days; almost half (49%) were removed within 5 days of insertion. A major or minor complication occurred in 10.3% of midlines, with minor complications such as dislodgement, leaking and infiltration accounting for 71% of all adverse events. While rates of major complications including occlusion, upper-extremity DVT and BSI were low (2.2%, 1.4% and 0.3%, respectively), they were just as likely to lead to midline removal as minor complications (53.8% vs 52.5%, p=0.90). Across hospitals, absolute volume of midlines placed varied from 100 to 1837 devices, with corresponding utilisation rates of 0.97%–12.92% (p<0.001). CONCLUSION: Midline use and outcomes vary widely across hospitals. Although rates of major complications are low, device removal as a result of adverse events is common. |
format | Online Article Text |
id | pubmed-6860966 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | BMJ Publishing Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-68609662019-12-03 Variation in use and outcomes related to midline catheters: results from a multicentre pilot study Chopra, Vineet Kaatz, Scott Swaminathan, Lakshmi Boldenow, Tanya Snyder, Ashley Burris, Rachel Bernstein, Steve J Flanders, Scott BMJ Qual Saf Original Research BACKGROUND: While midline vascular catheters are gaining popularity in clinical practice, patterns of use and outcomes related to these devices are not well known. METHODS: Trained abstractors collected data from medical records of hospitalised patients who received midline catheters in 12 hospitals. Device characteristics, patterns of use and outcomes were assessed at device removal or at 30 days. Rates of major (upper-extremity deep vein thrombosis [DVT], bloodstream infection [BSI] and catheter occlusion) and minor complications were assessed. χ(2) tests were used to examine differences in rates of complication by number of lumens, reasons for catheter removal l, and hospital-level differences in rates of midline use. RESULTS: Complete data on 1161 midlines representing 5%–72% of all midlines placed in participating hospitals between 1 January 2017 and 1 March 2018 were available. Most (70.8%) midlines were placed in general ward settings for difficult intravenous access (61.4%). The median dwell time of midlines across hospitals was 6 days; almost half (49%) were removed within 5 days of insertion. A major or minor complication occurred in 10.3% of midlines, with minor complications such as dislodgement, leaking and infiltration accounting for 71% of all adverse events. While rates of major complications including occlusion, upper-extremity DVT and BSI were low (2.2%, 1.4% and 0.3%, respectively), they were just as likely to lead to midline removal as minor complications (53.8% vs 52.5%, p=0.90). Across hospitals, absolute volume of midlines placed varied from 100 to 1837 devices, with corresponding utilisation rates of 0.97%–12.92% (p<0.001). CONCLUSION: Midline use and outcomes vary widely across hospitals. Although rates of major complications are low, device removal as a result of adverse events is common. BMJ Publishing Group 2019-09 2019-03-18 /pmc/articles/PMC6860966/ /pubmed/30886119 http://dx.doi.org/10.1136/bmjqs-2018-008554 Text en © Author(s) (or their employer(s)) 2019. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ. This is an open access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited, appropriate credit is given, any changes made indicated, and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/. |
spellingShingle | Original Research Chopra, Vineet Kaatz, Scott Swaminathan, Lakshmi Boldenow, Tanya Snyder, Ashley Burris, Rachel Bernstein, Steve J Flanders, Scott Variation in use and outcomes related to midline catheters: results from a multicentre pilot study |
title | Variation in use and outcomes related to midline catheters: results from a multicentre pilot study |
title_full | Variation in use and outcomes related to midline catheters: results from a multicentre pilot study |
title_fullStr | Variation in use and outcomes related to midline catheters: results from a multicentre pilot study |
title_full_unstemmed | Variation in use and outcomes related to midline catheters: results from a multicentre pilot study |
title_short | Variation in use and outcomes related to midline catheters: results from a multicentre pilot study |
title_sort | variation in use and outcomes related to midline catheters: results from a multicentre pilot study |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6860966/ https://www.ncbi.nlm.nih.gov/pubmed/30886119 http://dx.doi.org/10.1136/bmjqs-2018-008554 |
work_keys_str_mv | AT chopravineet variationinuseandoutcomesrelatedtomidlinecathetersresultsfromamulticentrepilotstudy AT kaatzscott variationinuseandoutcomesrelatedtomidlinecathetersresultsfromamulticentrepilotstudy AT swaminathanlakshmi variationinuseandoutcomesrelatedtomidlinecathetersresultsfromamulticentrepilotstudy AT boldenowtanya variationinuseandoutcomesrelatedtomidlinecathetersresultsfromamulticentrepilotstudy AT snyderashley variationinuseandoutcomesrelatedtomidlinecathetersresultsfromamulticentrepilotstudy AT burrisrachel variationinuseandoutcomesrelatedtomidlinecathetersresultsfromamulticentrepilotstudy AT bernsteinstevej variationinuseandoutcomesrelatedtomidlinecathetersresultsfromamulticentrepilotstudy AT flandersscott variationinuseandoutcomesrelatedtomidlinecathetersresultsfromamulticentrepilotstudy |