Cargando…
Investigating the Analytical Variability and Agreement of Manual Leukocyte Quantification Methods in Eastern Box Turtles (Terrapene carolina carolina)
Leukogram evaluation provides valuable information about inflammation, infection, and stress in free-living and zoo-maintained wildlife. While multiple protocols for quantifying leukocytes are available in reptiles, agreement between methods is infrequently described and analytical variability (incl...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6861175/ https://www.ncbi.nlm.nih.gov/pubmed/31781584 http://dx.doi.org/10.3389/fvets.2019.00398 |
_version_ | 1783471294811996160 |
---|---|
author | Winter, John M. Stacy, Nicole I. Adamovicz, Laura A. Allender, Matthew C. |
author_facet | Winter, John M. Stacy, Nicole I. Adamovicz, Laura A. Allender, Matthew C. |
author_sort | Winter, John M. |
collection | PubMed |
description | Leukogram evaluation provides valuable information about inflammation, infection, and stress in free-living and zoo-maintained wildlife. While multiple protocols for quantifying leukocytes are available in reptiles, agreement between methods is infrequently described and analytical variability (including repeatability and reproducibility) has not been critically evaluated. This study addresses these knowledge gaps for two hematological methods in eastern box turtles (Terrapene carolina carolina): Avian Leukopet(™) (LO) and total white blood cell (WBC) estimates from blood films (EST). The objectives of this study were (1) to evaluate agreement in total WBC and individual leukocyte counts between the LO and EST methods, (2) to document repeatability (intra-assay variability) and reproducibility (inter-assay variability) for the LO method, and (3) to investigate whether biological drivers of WBC counts differ between quantification methods. Box turtles (n = 120) were sampled from five study sites in Illinois during the 2018 active season. The LO method produced significantly higher WBC counts than the EST method, and constant and proportional error was variable for each leukocyte type. The LO method demonstrated an intra-assay variability of 8.2% and an inter-assay variability of 12%, independent of biological variation. WBC counts were significantly affected by age class using both LO and EST methods, but WBC differences between locations and sexes were only observed using the LO method. These findings emphasize the importance of considering leukocyte determination method when analyzing reptilian hematology results. The inherent variability in currently available methods creates uncertainty in resulting data and highlights the need of a gold standard for reptilian WBC quantification. |
format | Online Article Text |
id | pubmed-6861175 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-68611752019-11-28 Investigating the Analytical Variability and Agreement of Manual Leukocyte Quantification Methods in Eastern Box Turtles (Terrapene carolina carolina) Winter, John M. Stacy, Nicole I. Adamovicz, Laura A. Allender, Matthew C. Front Vet Sci Veterinary Science Leukogram evaluation provides valuable information about inflammation, infection, and stress in free-living and zoo-maintained wildlife. While multiple protocols for quantifying leukocytes are available in reptiles, agreement between methods is infrequently described and analytical variability (including repeatability and reproducibility) has not been critically evaluated. This study addresses these knowledge gaps for two hematological methods in eastern box turtles (Terrapene carolina carolina): Avian Leukopet(™) (LO) and total white blood cell (WBC) estimates from blood films (EST). The objectives of this study were (1) to evaluate agreement in total WBC and individual leukocyte counts between the LO and EST methods, (2) to document repeatability (intra-assay variability) and reproducibility (inter-assay variability) for the LO method, and (3) to investigate whether biological drivers of WBC counts differ between quantification methods. Box turtles (n = 120) were sampled from five study sites in Illinois during the 2018 active season. The LO method produced significantly higher WBC counts than the EST method, and constant and proportional error was variable for each leukocyte type. The LO method demonstrated an intra-assay variability of 8.2% and an inter-assay variability of 12%, independent of biological variation. WBC counts were significantly affected by age class using both LO and EST methods, but WBC differences between locations and sexes were only observed using the LO method. These findings emphasize the importance of considering leukocyte determination method when analyzing reptilian hematology results. The inherent variability in currently available methods creates uncertainty in resulting data and highlights the need of a gold standard for reptilian WBC quantification. Frontiers Media S.A. 2019-11-12 /pmc/articles/PMC6861175/ /pubmed/31781584 http://dx.doi.org/10.3389/fvets.2019.00398 Text en Copyright © 2019 Winter, Stacy, Adamovicz and Allender. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Veterinary Science Winter, John M. Stacy, Nicole I. Adamovicz, Laura A. Allender, Matthew C. Investigating the Analytical Variability and Agreement of Manual Leukocyte Quantification Methods in Eastern Box Turtles (Terrapene carolina carolina) |
title | Investigating the Analytical Variability and Agreement of Manual Leukocyte Quantification Methods in Eastern Box Turtles (Terrapene carolina carolina) |
title_full | Investigating the Analytical Variability and Agreement of Manual Leukocyte Quantification Methods in Eastern Box Turtles (Terrapene carolina carolina) |
title_fullStr | Investigating the Analytical Variability and Agreement of Manual Leukocyte Quantification Methods in Eastern Box Turtles (Terrapene carolina carolina) |
title_full_unstemmed | Investigating the Analytical Variability and Agreement of Manual Leukocyte Quantification Methods in Eastern Box Turtles (Terrapene carolina carolina) |
title_short | Investigating the Analytical Variability and Agreement of Manual Leukocyte Quantification Methods in Eastern Box Turtles (Terrapene carolina carolina) |
title_sort | investigating the analytical variability and agreement of manual leukocyte quantification methods in eastern box turtles (terrapene carolina carolina) |
topic | Veterinary Science |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6861175/ https://www.ncbi.nlm.nih.gov/pubmed/31781584 http://dx.doi.org/10.3389/fvets.2019.00398 |
work_keys_str_mv | AT winterjohnm investigatingtheanalyticalvariabilityandagreementofmanualleukocytequantificationmethodsineasternboxturtlesterrapenecarolinacarolina AT stacynicolei investigatingtheanalyticalvariabilityandagreementofmanualleukocytequantificationmethodsineasternboxturtlesterrapenecarolinacarolina AT adamoviczlauraa investigatingtheanalyticalvariabilityandagreementofmanualleukocytequantificationmethodsineasternboxturtlesterrapenecarolinacarolina AT allendermatthewc investigatingtheanalyticalvariabilityandagreementofmanualleukocytequantificationmethodsineasternboxturtlesterrapenecarolinacarolina |