Cargando…

Geometric Remodeling of the Perirenal Aortic Neck at and Adjacent to the Double Sealing Ring of the Anaconda Stent-Graft After Endovascular Aneurysm Repair

Purpose: To evaluate if the radial force of the double sealing ring of the Anaconda stent-graft induces dilatation in the perirenal aortic neck adjacent to the rings. Materials and Methods: This study evaluated the serial electrocardiogram-gated computed tomography scans of 15 abdominal aortic aneur...

Descripción completa

Detalles Bibliográficos
Autores principales: Koenrades, Maaike A., Bosscher, Marianne R. F., Ubbink, Jouke T., Slump, Cornelis H., Geelkerken, Robert H.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6864107/
https://www.ncbi.nlm.nih.gov/pubmed/31736427
http://dx.doi.org/10.1177/1526602819882379
_version_ 1783471825773133824
author Koenrades, Maaike A.
Bosscher, Marianne R. F.
Ubbink, Jouke T.
Slump, Cornelis H.
Geelkerken, Robert H.
author_facet Koenrades, Maaike A.
Bosscher, Marianne R. F.
Ubbink, Jouke T.
Slump, Cornelis H.
Geelkerken, Robert H.
author_sort Koenrades, Maaike A.
collection PubMed
description Purpose: To evaluate if the radial force of the double sealing ring of the Anaconda stent-graft induces dilatation in the perirenal aortic neck adjacent to the rings. Materials and Methods: This study evaluated the serial electrocardiogram-gated computed tomography scans of 15 abdominal aortic aneurysm patients (mean age 72.8±3.7 years; 14 men) who were treated electively using an Anaconda stent-graft. Follow-up scans were conducted before discharge and at 1, 6, 12, and 24 months after endovascular repair. Diameter and area were assessed perpendicular to the aortic centerline along the perirenal aortic neck, which was subdivided into 3 zones: the suprastent, the stent, and the infrastent zones. Measurements were performed independently by 2 experienced observers using dedicated 3-dimensional image processing software. Results: Between discharge and the 2-year follow-up the diameter and area remained stable in the suprastent zone [average diameter change: −0.1±0.4 mm (−0.4%±1.7%), p=0.893; average area change: −2.9±17.2 mm(2) (−0.7%±3.4%), p=0.946], increased in the stent zone [average diameter change: +1.9±1.0 mm (+7.3%±4.0%), p<0.001; average area change: +84.3±48.3 mm(2) (+15.5%±8.7%), p<0.001], and diverged in the infrastent zone [average diameter change: −0.8±2.2 mm (−2.3%±7.4%), p>0.99; average area change: −34.6±102.3 mm(2) (−4.1%±14.8%), p>0.99; increased in 4 patients, decreased in 9 patients]. Conclusion: After Anaconda implantation the infrarenal aortic neck accommodated to the expansion of the sealing rings at the stent zone. Below the stent zone the neck diameter decreased in the majority of patients, while an increase was related to downstream displacement of the main body. A decrease in size in the infrastent zone may contribute to durable sealing and fixation. A personalized follow-up scheme based on geometric neck remodeling should be feasible if our observations are confirmed in larger, long-term studies.
format Online
Article
Text
id pubmed-6864107
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-68641072019-12-12 Geometric Remodeling of the Perirenal Aortic Neck at and Adjacent to the Double Sealing Ring of the Anaconda Stent-Graft After Endovascular Aneurysm Repair Koenrades, Maaike A. Bosscher, Marianne R. F. Ubbink, Jouke T. Slump, Cornelis H. Geelkerken, Robert H. J Endovasc Ther Endovascular Aneurysm Repair Purpose: To evaluate if the radial force of the double sealing ring of the Anaconda stent-graft induces dilatation in the perirenal aortic neck adjacent to the rings. Materials and Methods: This study evaluated the serial electrocardiogram-gated computed tomography scans of 15 abdominal aortic aneurysm patients (mean age 72.8±3.7 years; 14 men) who were treated electively using an Anaconda stent-graft. Follow-up scans were conducted before discharge and at 1, 6, 12, and 24 months after endovascular repair. Diameter and area were assessed perpendicular to the aortic centerline along the perirenal aortic neck, which was subdivided into 3 zones: the suprastent, the stent, and the infrastent zones. Measurements were performed independently by 2 experienced observers using dedicated 3-dimensional image processing software. Results: Between discharge and the 2-year follow-up the diameter and area remained stable in the suprastent zone [average diameter change: −0.1±0.4 mm (−0.4%±1.7%), p=0.893; average area change: −2.9±17.2 mm(2) (−0.7%±3.4%), p=0.946], increased in the stent zone [average diameter change: +1.9±1.0 mm (+7.3%±4.0%), p<0.001; average area change: +84.3±48.3 mm(2) (+15.5%±8.7%), p<0.001], and diverged in the infrastent zone [average diameter change: −0.8±2.2 mm (−2.3%±7.4%), p>0.99; average area change: −34.6±102.3 mm(2) (−4.1%±14.8%), p>0.99; increased in 4 patients, decreased in 9 patients]. Conclusion: After Anaconda implantation the infrarenal aortic neck accommodated to the expansion of the sealing rings at the stent zone. Below the stent zone the neck diameter decreased in the majority of patients, while an increase was related to downstream displacement of the main body. A decrease in size in the infrastent zone may contribute to durable sealing and fixation. A personalized follow-up scheme based on geometric neck remodeling should be feasible if our observations are confirmed in larger, long-term studies. SAGE Publications 2019-11-18 2019-12 /pmc/articles/PMC6864107/ /pubmed/31736427 http://dx.doi.org/10.1177/1526602819882379 Text en © The Author(s) 2019 http://creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (http://www.creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Endovascular Aneurysm Repair
Koenrades, Maaike A.
Bosscher, Marianne R. F.
Ubbink, Jouke T.
Slump, Cornelis H.
Geelkerken, Robert H.
Geometric Remodeling of the Perirenal Aortic Neck at and Adjacent to the Double Sealing Ring of the Anaconda Stent-Graft After Endovascular Aneurysm Repair
title Geometric Remodeling of the Perirenal Aortic Neck at and Adjacent to the Double Sealing Ring of the Anaconda Stent-Graft After Endovascular Aneurysm Repair
title_full Geometric Remodeling of the Perirenal Aortic Neck at and Adjacent to the Double Sealing Ring of the Anaconda Stent-Graft After Endovascular Aneurysm Repair
title_fullStr Geometric Remodeling of the Perirenal Aortic Neck at and Adjacent to the Double Sealing Ring of the Anaconda Stent-Graft After Endovascular Aneurysm Repair
title_full_unstemmed Geometric Remodeling of the Perirenal Aortic Neck at and Adjacent to the Double Sealing Ring of the Anaconda Stent-Graft After Endovascular Aneurysm Repair
title_short Geometric Remodeling of the Perirenal Aortic Neck at and Adjacent to the Double Sealing Ring of the Anaconda Stent-Graft After Endovascular Aneurysm Repair
title_sort geometric remodeling of the perirenal aortic neck at and adjacent to the double sealing ring of the anaconda stent-graft after endovascular aneurysm repair
topic Endovascular Aneurysm Repair
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6864107/
https://www.ncbi.nlm.nih.gov/pubmed/31736427
http://dx.doi.org/10.1177/1526602819882379
work_keys_str_mv AT koenradesmaaikea geometricremodelingoftheperirenalaorticneckatandadjacenttothedoublesealingringoftheanacondastentgraftafterendovascularaneurysmrepair
AT bosschermariannerf geometricremodelingoftheperirenalaorticneckatandadjacenttothedoublesealingringoftheanacondastentgraftafterendovascularaneurysmrepair
AT ubbinkjouket geometricremodelingoftheperirenalaorticneckatandadjacenttothedoublesealingringoftheanacondastentgraftafterendovascularaneurysmrepair
AT slumpcornelish geometricremodelingoftheperirenalaorticneckatandadjacenttothedoublesealingringoftheanacondastentgraftafterendovascularaneurysmrepair
AT geelkerkenroberth geometricremodelingoftheperirenalaorticneckatandadjacenttothedoublesealingringoftheanacondastentgraftafterendovascularaneurysmrepair