Cargando…
A SAFT Method for the Detection of Void Defect inside a Ballastless Track Structure Using Ultrasonic Array Sensors
High-precision ultrasound imaging of void defects is critical for the performance and safety assessment of ballastless track structures. The sound propagation velocity of each layer in the ballastless track structure is quite different. However, the traditional concrete Synthetic Aperture Focusing T...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6864854/ https://www.ncbi.nlm.nih.gov/pubmed/31661867 http://dx.doi.org/10.3390/s19214677 |
_version_ | 1783471976439873536 |
---|---|
author | Zhu, Wen-Fa Chen, Xing-Jie Li, Zai-Wei Meng, Xiang-Zhen Fan, Guo-Peng Shao, Wei Zhang, Hai-Yan |
author_facet | Zhu, Wen-Fa Chen, Xing-Jie Li, Zai-Wei Meng, Xiang-Zhen Fan, Guo-Peng Shao, Wei Zhang, Hai-Yan |
author_sort | Zhu, Wen-Fa |
collection | PubMed |
description | High-precision ultrasound imaging of void defects is critical for the performance and safety assessment of ballastless track structures. The sound propagation velocity of each layer in the ballastless track structure is quite different. However, the traditional concrete Synthetic Aperture Focusing Technique (SAFT) ultrasound imaging method is based on the assumption that the concrete has a single constant shear wave velocity. Thus, it is not a suitable method for the ultrasonic imaging of multilayer structures. In this paper, a Multilayer SAFT high-precision ultrasound imaging method is proposed. It is based on the ray-tracing technique and uses the Fermat principle to find the refraction point that minimizes the delay of the acoustic wave propagation path at the interface of the discrete layers. Then, the acoustic wave propagation path is segmented by the position of the refraction point, and the propagation delay of the ultrasonic wave is obtained segment by segment. Thus, the propagation delay of the ultrasonic wave is obtained one by one, so that the propagation delay of the ultrasonic wave in the multilayer structure can be accurately obtained. Finally, the focused image is obtained according to the SAFT imaging algorithm. The finite element simulation and experimental results show that the Multilayer SAFT imaging method can accurately track the propagation path of the ultrasonic wave in ballastless track structures, as well as accurately calculate the propagation delay of the ultrasonic wave and the lengths of void defects. The high accuracy of the Multilayer SAFT imaging represents a significant improvement compared to traditional SAFT imaging. |
format | Online Article Text |
id | pubmed-6864854 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-68648542019-12-06 A SAFT Method for the Detection of Void Defect inside a Ballastless Track Structure Using Ultrasonic Array Sensors Zhu, Wen-Fa Chen, Xing-Jie Li, Zai-Wei Meng, Xiang-Zhen Fan, Guo-Peng Shao, Wei Zhang, Hai-Yan Sensors (Basel) Article High-precision ultrasound imaging of void defects is critical for the performance and safety assessment of ballastless track structures. The sound propagation velocity of each layer in the ballastless track structure is quite different. However, the traditional concrete Synthetic Aperture Focusing Technique (SAFT) ultrasound imaging method is based on the assumption that the concrete has a single constant shear wave velocity. Thus, it is not a suitable method for the ultrasonic imaging of multilayer structures. In this paper, a Multilayer SAFT high-precision ultrasound imaging method is proposed. It is based on the ray-tracing technique and uses the Fermat principle to find the refraction point that minimizes the delay of the acoustic wave propagation path at the interface of the discrete layers. Then, the acoustic wave propagation path is segmented by the position of the refraction point, and the propagation delay of the ultrasonic wave is obtained segment by segment. Thus, the propagation delay of the ultrasonic wave is obtained one by one, so that the propagation delay of the ultrasonic wave in the multilayer structure can be accurately obtained. Finally, the focused image is obtained according to the SAFT imaging algorithm. The finite element simulation and experimental results show that the Multilayer SAFT imaging method can accurately track the propagation path of the ultrasonic wave in ballastless track structures, as well as accurately calculate the propagation delay of the ultrasonic wave and the lengths of void defects. The high accuracy of the Multilayer SAFT imaging represents a significant improvement compared to traditional SAFT imaging. MDPI 2019-10-28 /pmc/articles/PMC6864854/ /pubmed/31661867 http://dx.doi.org/10.3390/s19214677 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Zhu, Wen-Fa Chen, Xing-Jie Li, Zai-Wei Meng, Xiang-Zhen Fan, Guo-Peng Shao, Wei Zhang, Hai-Yan A SAFT Method for the Detection of Void Defect inside a Ballastless Track Structure Using Ultrasonic Array Sensors |
title | A SAFT Method for the Detection of Void Defect inside a Ballastless Track Structure Using Ultrasonic Array Sensors |
title_full | A SAFT Method for the Detection of Void Defect inside a Ballastless Track Structure Using Ultrasonic Array Sensors |
title_fullStr | A SAFT Method for the Detection of Void Defect inside a Ballastless Track Structure Using Ultrasonic Array Sensors |
title_full_unstemmed | A SAFT Method for the Detection of Void Defect inside a Ballastless Track Structure Using Ultrasonic Array Sensors |
title_short | A SAFT Method for the Detection of Void Defect inside a Ballastless Track Structure Using Ultrasonic Array Sensors |
title_sort | saft method for the detection of void defect inside a ballastless track structure using ultrasonic array sensors |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6864854/ https://www.ncbi.nlm.nih.gov/pubmed/31661867 http://dx.doi.org/10.3390/s19214677 |
work_keys_str_mv | AT zhuwenfa asaftmethodforthedetectionofvoiddefectinsideaballastlesstrackstructureusingultrasonicarraysensors AT chenxingjie asaftmethodforthedetectionofvoiddefectinsideaballastlesstrackstructureusingultrasonicarraysensors AT lizaiwei asaftmethodforthedetectionofvoiddefectinsideaballastlesstrackstructureusingultrasonicarraysensors AT mengxiangzhen asaftmethodforthedetectionofvoiddefectinsideaballastlesstrackstructureusingultrasonicarraysensors AT fanguopeng asaftmethodforthedetectionofvoiddefectinsideaballastlesstrackstructureusingultrasonicarraysensors AT shaowei asaftmethodforthedetectionofvoiddefectinsideaballastlesstrackstructureusingultrasonicarraysensors AT zhanghaiyan asaftmethodforthedetectionofvoiddefectinsideaballastlesstrackstructureusingultrasonicarraysensors AT zhuwenfa saftmethodforthedetectionofvoiddefectinsideaballastlesstrackstructureusingultrasonicarraysensors AT chenxingjie saftmethodforthedetectionofvoiddefectinsideaballastlesstrackstructureusingultrasonicarraysensors AT lizaiwei saftmethodforthedetectionofvoiddefectinsideaballastlesstrackstructureusingultrasonicarraysensors AT mengxiangzhen saftmethodforthedetectionofvoiddefectinsideaballastlesstrackstructureusingultrasonicarraysensors AT fanguopeng saftmethodforthedetectionofvoiddefectinsideaballastlesstrackstructureusingultrasonicarraysensors AT shaowei saftmethodforthedetectionofvoiddefectinsideaballastlesstrackstructureusingultrasonicarraysensors AT zhanghaiyan saftmethodforthedetectionofvoiddefectinsideaballastlesstrackstructureusingultrasonicarraysensors |