Cargando…

Noninvasive Analysis of Tree Stems by Electrical Resistivity Tomography: Unraveling the Effects of Temperature, Water Status, and Electrode Installation

The increasing demand for tree and forest health monitoring due to ongoing climate change requires new future-oriented and nondestructive measurement techniques. Electrical resistivity (ER) tomography represents a promising and innovative approach, as it allows insights into living trees based on ER...

Descripción completa

Detalles Bibliográficos
Autores principales: Ganthaler, Andrea, Sailer, Julia, Bär, Andreas, Losso, Adriano, Mayr, Stefan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6865845/
https://www.ncbi.nlm.nih.gov/pubmed/31798610
http://dx.doi.org/10.3389/fpls.2019.01455
_version_ 1783472081426448384
author Ganthaler, Andrea
Sailer, Julia
Bär, Andreas
Losso, Adriano
Mayr, Stefan
author_facet Ganthaler, Andrea
Sailer, Julia
Bär, Andreas
Losso, Adriano
Mayr, Stefan
author_sort Ganthaler, Andrea
collection PubMed
description The increasing demand for tree and forest health monitoring due to ongoing climate change requires new future-oriented and nondestructive measurement techniques. Electrical resistivity (ER) tomography represents a promising and innovative approach, as it allows insights into living trees based on ER levels and ER cross-sectional distribution patterns of stems. However, it is poorly understood how external factors, such as temperature, tree water status, and electrode installation affect ER tomograms. In this study, ER measurements were carried out on three angiosperms (Betula pendula, Fagus sylvatica, Populus nigra) and three conifers (Larix decidua, Picea abies, Pinus cembra) exposed to temperatures between −10 and 30°C and to continuous dehydration down to −6.3 MPa in a laboratory experiment. Additionally, effects of removal of peripheral tissues (periderm, phloem, cambium) and electrode installation were tested. Temperature changes above the freezing point did not affect ER distribution patterns but average ER levels, which increased exponentially and about 2.5-fold from 30 to 0°C in all species. In contrast, freezing of stems caused a pronounced raise of ER, especially in peripheral areas. With progressive tree dehydration, average ER increased in all species except in B. pendula, and measured resistivities in the peripheral stem areas of both angiosperms and conifers were clearly linearly related to the tree water status. Removal of the periderm resulted in a slight decrease of high ER peaks. Installation of electrodes for a short period of 32–72 h before conducting the tomography caused small distortions in tomograms. Distortions became serious after long-term installation for several months, while mean ER was only slightly affected. The present study confirms that ER tomography of tree stems is sensitive to temperature and water status. Results help to improve ER tomogram interpretation and suggest that ER analyses may be suitable to nondestructively determinate the hydraulic status of trees. They thus provide a solid basis for further technological developments to enable presymptomatic detection of physiological stress in standing trees.
format Online
Article
Text
id pubmed-6865845
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-68658452019-12-03 Noninvasive Analysis of Tree Stems by Electrical Resistivity Tomography: Unraveling the Effects of Temperature, Water Status, and Electrode Installation Ganthaler, Andrea Sailer, Julia Bär, Andreas Losso, Adriano Mayr, Stefan Front Plant Sci Plant Science The increasing demand for tree and forest health monitoring due to ongoing climate change requires new future-oriented and nondestructive measurement techniques. Electrical resistivity (ER) tomography represents a promising and innovative approach, as it allows insights into living trees based on ER levels and ER cross-sectional distribution patterns of stems. However, it is poorly understood how external factors, such as temperature, tree water status, and electrode installation affect ER tomograms. In this study, ER measurements were carried out on three angiosperms (Betula pendula, Fagus sylvatica, Populus nigra) and three conifers (Larix decidua, Picea abies, Pinus cembra) exposed to temperatures between −10 and 30°C and to continuous dehydration down to −6.3 MPa in a laboratory experiment. Additionally, effects of removal of peripheral tissues (periderm, phloem, cambium) and electrode installation were tested. Temperature changes above the freezing point did not affect ER distribution patterns but average ER levels, which increased exponentially and about 2.5-fold from 30 to 0°C in all species. In contrast, freezing of stems caused a pronounced raise of ER, especially in peripheral areas. With progressive tree dehydration, average ER increased in all species except in B. pendula, and measured resistivities in the peripheral stem areas of both angiosperms and conifers were clearly linearly related to the tree water status. Removal of the periderm resulted in a slight decrease of high ER peaks. Installation of electrodes for a short period of 32–72 h before conducting the tomography caused small distortions in tomograms. Distortions became serious after long-term installation for several months, while mean ER was only slightly affected. The present study confirms that ER tomography of tree stems is sensitive to temperature and water status. Results help to improve ER tomogram interpretation and suggest that ER analyses may be suitable to nondestructively determinate the hydraulic status of trees. They thus provide a solid basis for further technological developments to enable presymptomatic detection of physiological stress in standing trees. Frontiers Media S.A. 2019-11-13 /pmc/articles/PMC6865845/ /pubmed/31798610 http://dx.doi.org/10.3389/fpls.2019.01455 Text en Copyright © 2019 Ganthaler, Sailer, Bär, Losso and Mayr http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Plant Science
Ganthaler, Andrea
Sailer, Julia
Bär, Andreas
Losso, Adriano
Mayr, Stefan
Noninvasive Analysis of Tree Stems by Electrical Resistivity Tomography: Unraveling the Effects of Temperature, Water Status, and Electrode Installation
title Noninvasive Analysis of Tree Stems by Electrical Resistivity Tomography: Unraveling the Effects of Temperature, Water Status, and Electrode Installation
title_full Noninvasive Analysis of Tree Stems by Electrical Resistivity Tomography: Unraveling the Effects of Temperature, Water Status, and Electrode Installation
title_fullStr Noninvasive Analysis of Tree Stems by Electrical Resistivity Tomography: Unraveling the Effects of Temperature, Water Status, and Electrode Installation
title_full_unstemmed Noninvasive Analysis of Tree Stems by Electrical Resistivity Tomography: Unraveling the Effects of Temperature, Water Status, and Electrode Installation
title_short Noninvasive Analysis of Tree Stems by Electrical Resistivity Tomography: Unraveling the Effects of Temperature, Water Status, and Electrode Installation
title_sort noninvasive analysis of tree stems by electrical resistivity tomography: unraveling the effects of temperature, water status, and electrode installation
topic Plant Science
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6865845/
https://www.ncbi.nlm.nih.gov/pubmed/31798610
http://dx.doi.org/10.3389/fpls.2019.01455
work_keys_str_mv AT ganthalerandrea noninvasiveanalysisoftreestemsbyelectricalresistivitytomographyunravelingtheeffectsoftemperaturewaterstatusandelectrodeinstallation
AT sailerjulia noninvasiveanalysisoftreestemsbyelectricalresistivitytomographyunravelingtheeffectsoftemperaturewaterstatusandelectrodeinstallation
AT barandreas noninvasiveanalysisoftreestemsbyelectricalresistivitytomographyunravelingtheeffectsoftemperaturewaterstatusandelectrodeinstallation
AT lossoadriano noninvasiveanalysisoftreestemsbyelectricalresistivitytomographyunravelingtheeffectsoftemperaturewaterstatusandelectrodeinstallation
AT mayrstefan noninvasiveanalysisoftreestemsbyelectricalresistivitytomographyunravelingtheeffectsoftemperaturewaterstatusandelectrodeinstallation