Cargando…
Comparison of continuous wave and cold lateral condensation filling techniques in 3D printed simulated C-shape canals instrumented with Reciproc Blue or Hyflex EDM
AIM: To compare the efficiency of continuous wave obturation and cold lateral condensation techniques and filling time in C-shape canals of 3-dimensional (3D)-printed resin teeth shaped with Reciproc Blue (VDW) or Hyflex EDM (Coltene/Whaledent). METHODOLOGY: One tooth with C1-type orifice and root c...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6871781/ https://www.ncbi.nlm.nih.gov/pubmed/31751375 http://dx.doi.org/10.1371/journal.pone.0224793 |
_version_ | 1783472432101720064 |
---|---|
author | Karatekin, Anıl Özgün Keleş, Ali Gençoğlu, Nimet |
author_facet | Karatekin, Anıl Özgün Keleş, Ali Gençoğlu, Nimet |
author_sort | Karatekin, Anıl Özgün |
collection | PubMed |
description | AIM: To compare the efficiency of continuous wave obturation and cold lateral condensation techniques and filling time in C-shape canals of 3-dimensional (3D)-printed resin teeth shaped with Reciproc Blue (VDW) or Hyflex EDM (Coltene/Whaledent). METHODOLOGY: One tooth with C1-type orifice and root canal morphology and one with C2-type orifice and C2-C3 root canal morphology were selected based on CBCT. Two replicas of selected teeth were manufactured with a 3D-printer and their canals were instrumented with Reciproc Blue or Hyflex EDM. These 4 instrumented replicas were scanned with CBCT. Identical 10 replicas of each group (total of 40) were produced using a 3D-printer and randomly divided into 2 groups (n = 5), root filled with either continuous wave obturation (CW) or cold lateral condensation (LC). Horizontal cross-sections of C1-type were made at 2, 4, 6, 8 mm and C2-type at 2, 4, 6 mm from the apical foramen. Gutta-percha, sealer and void areas were evaluated with image analysis sofware. Data were analysed using nonparametric Kruskal-Wallis and Mann Whitney-U tests and the Factorial ANOVA was used for interaction effects. Time required to fill canals was evaluated using the Mann-Whitney U test. RESULTS: For C1-type, LC had more gutta-percha and less sealer compared to CW in 2-mm sections (p<0.05). CW had greater percentages of gutta-percha and lower percentages of sealer compared with LC group in 4, 6, 8 mm sections and total area (p<0.05). LC group had higher percentages of voids compared to CW group in 2 and 4 mm sections (p<0.05). For C2-type, CW had more gutta-percha and less sealer versus LC group in all sections and total area (p<0.05). LC had the least gutta-percha and greatest sealer percentages at 6-mm sections (p<0.05). There was no statistically significant difference in the percentages of voids at any level of sections between the filling techniques (p>0.05). In both C-types, there was no significant difference in the percentages of gutta-percha, sealer and voids between Reciproc Blue and Hyflex EDM-shaped groups at any level (p>0.05). Time spent for the LC technique and filling C1-type was significantly longer than when using the CW technique and filling C2-type (p<0.05). CONCLUSIONS: Continuous wave obturation was more effective than lateral condensation in both C1- and C2-type, except for the apical 2 mm section of C1-type, suggesting the need for a modified CW technique. |
format | Online Article Text |
id | pubmed-6871781 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-68717812019-12-08 Comparison of continuous wave and cold lateral condensation filling techniques in 3D printed simulated C-shape canals instrumented with Reciproc Blue or Hyflex EDM Karatekin, Anıl Özgün Keleş, Ali Gençoğlu, Nimet PLoS One Research Article AIM: To compare the efficiency of continuous wave obturation and cold lateral condensation techniques and filling time in C-shape canals of 3-dimensional (3D)-printed resin teeth shaped with Reciproc Blue (VDW) or Hyflex EDM (Coltene/Whaledent). METHODOLOGY: One tooth with C1-type orifice and root canal morphology and one with C2-type orifice and C2-C3 root canal morphology were selected based on CBCT. Two replicas of selected teeth were manufactured with a 3D-printer and their canals were instrumented with Reciproc Blue or Hyflex EDM. These 4 instrumented replicas were scanned with CBCT. Identical 10 replicas of each group (total of 40) were produced using a 3D-printer and randomly divided into 2 groups (n = 5), root filled with either continuous wave obturation (CW) or cold lateral condensation (LC). Horizontal cross-sections of C1-type were made at 2, 4, 6, 8 mm and C2-type at 2, 4, 6 mm from the apical foramen. Gutta-percha, sealer and void areas were evaluated with image analysis sofware. Data were analysed using nonparametric Kruskal-Wallis and Mann Whitney-U tests and the Factorial ANOVA was used for interaction effects. Time required to fill canals was evaluated using the Mann-Whitney U test. RESULTS: For C1-type, LC had more gutta-percha and less sealer compared to CW in 2-mm sections (p<0.05). CW had greater percentages of gutta-percha and lower percentages of sealer compared with LC group in 4, 6, 8 mm sections and total area (p<0.05). LC group had higher percentages of voids compared to CW group in 2 and 4 mm sections (p<0.05). For C2-type, CW had more gutta-percha and less sealer versus LC group in all sections and total area (p<0.05). LC had the least gutta-percha and greatest sealer percentages at 6-mm sections (p<0.05). There was no statistically significant difference in the percentages of voids at any level of sections between the filling techniques (p>0.05). In both C-types, there was no significant difference in the percentages of gutta-percha, sealer and voids between Reciproc Blue and Hyflex EDM-shaped groups at any level (p>0.05). Time spent for the LC technique and filling C1-type was significantly longer than when using the CW technique and filling C2-type (p<0.05). CONCLUSIONS: Continuous wave obturation was more effective than lateral condensation in both C1- and C2-type, except for the apical 2 mm section of C1-type, suggesting the need for a modified CW technique. Public Library of Science 2019-11-21 /pmc/articles/PMC6871781/ /pubmed/31751375 http://dx.doi.org/10.1371/journal.pone.0224793 Text en © 2019 Karatekin et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Karatekin, Anıl Özgün Keleş, Ali Gençoğlu, Nimet Comparison of continuous wave and cold lateral condensation filling techniques in 3D printed simulated C-shape canals instrumented with Reciproc Blue or Hyflex EDM |
title | Comparison of continuous wave and cold lateral condensation filling techniques in 3D printed simulated C-shape canals instrumented with Reciproc Blue or Hyflex EDM |
title_full | Comparison of continuous wave and cold lateral condensation filling techniques in 3D printed simulated C-shape canals instrumented with Reciproc Blue or Hyflex EDM |
title_fullStr | Comparison of continuous wave and cold lateral condensation filling techniques in 3D printed simulated C-shape canals instrumented with Reciproc Blue or Hyflex EDM |
title_full_unstemmed | Comparison of continuous wave and cold lateral condensation filling techniques in 3D printed simulated C-shape canals instrumented with Reciproc Blue or Hyflex EDM |
title_short | Comparison of continuous wave and cold lateral condensation filling techniques in 3D printed simulated C-shape canals instrumented with Reciproc Blue or Hyflex EDM |
title_sort | comparison of continuous wave and cold lateral condensation filling techniques in 3d printed simulated c-shape canals instrumented with reciproc blue or hyflex edm |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6871781/ https://www.ncbi.nlm.nih.gov/pubmed/31751375 http://dx.doi.org/10.1371/journal.pone.0224793 |
work_keys_str_mv | AT karatekinanılozgun comparisonofcontinuouswaveandcoldlateralcondensationfillingtechniquesin3dprintedsimulatedcshapecanalsinstrumentedwithreciprocblueorhyflexedm AT kelesali comparisonofcontinuouswaveandcoldlateralcondensationfillingtechniquesin3dprintedsimulatedcshapecanalsinstrumentedwithreciprocblueorhyflexedm AT gencoglunimet comparisonofcontinuouswaveandcoldlateralcondensationfillingtechniquesin3dprintedsimulatedcshapecanalsinstrumentedwithreciprocblueorhyflexedm |