Cargando…

Comparison of continuous wave and cold lateral condensation filling techniques in 3D printed simulated C-shape canals instrumented with Reciproc Blue or Hyflex EDM

AIM: To compare the efficiency of continuous wave obturation and cold lateral condensation techniques and filling time in C-shape canals of 3-dimensional (3D)-printed resin teeth shaped with Reciproc Blue (VDW) or Hyflex EDM (Coltene/Whaledent). METHODOLOGY: One tooth with C1-type orifice and root c...

Descripción completa

Detalles Bibliográficos
Autores principales: Karatekin, Anıl Özgün, Keleş, Ali, Gençoğlu, Nimet
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6871781/
https://www.ncbi.nlm.nih.gov/pubmed/31751375
http://dx.doi.org/10.1371/journal.pone.0224793
_version_ 1783472432101720064
author Karatekin, Anıl Özgün
Keleş, Ali
Gençoğlu, Nimet
author_facet Karatekin, Anıl Özgün
Keleş, Ali
Gençoğlu, Nimet
author_sort Karatekin, Anıl Özgün
collection PubMed
description AIM: To compare the efficiency of continuous wave obturation and cold lateral condensation techniques and filling time in C-shape canals of 3-dimensional (3D)-printed resin teeth shaped with Reciproc Blue (VDW) or Hyflex EDM (Coltene/Whaledent). METHODOLOGY: One tooth with C1-type orifice and root canal morphology and one with C2-type orifice and C2-C3 root canal morphology were selected based on CBCT. Two replicas of selected teeth were manufactured with a 3D-printer and their canals were instrumented with Reciproc Blue or Hyflex EDM. These 4 instrumented replicas were scanned with CBCT. Identical 10 replicas of each group (total of 40) were produced using a 3D-printer and randomly divided into 2 groups (n = 5), root filled with either continuous wave obturation (CW) or cold lateral condensation (LC). Horizontal cross-sections of C1-type were made at 2, 4, 6, 8 mm and C2-type at 2, 4, 6 mm from the apical foramen. Gutta-percha, sealer and void areas were evaluated with image analysis sofware. Data were analysed using nonparametric Kruskal-Wallis and Mann Whitney-U tests and the Factorial ANOVA was used for interaction effects. Time required to fill canals was evaluated using the Mann-Whitney U test. RESULTS: For C1-type, LC had more gutta-percha and less sealer compared to CW in 2-mm sections (p<0.05). CW had greater percentages of gutta-percha and lower percentages of sealer compared with LC group in 4, 6, 8 mm sections and total area (p<0.05). LC group had higher percentages of voids compared to CW group in 2 and 4 mm sections (p<0.05). For C2-type, CW had more gutta-percha and less sealer versus LC group in all sections and total area (p<0.05). LC had the least gutta-percha and greatest sealer percentages at 6-mm sections (p<0.05). There was no statistically significant difference in the percentages of voids at any level of sections between the filling techniques (p>0.05). In both C-types, there was no significant difference in the percentages of gutta-percha, sealer and voids between Reciproc Blue and Hyflex EDM-shaped groups at any level (p>0.05). Time spent for the LC technique and filling C1-type was significantly longer than when using the CW technique and filling C2-type (p<0.05). CONCLUSIONS: Continuous wave obturation was more effective than lateral condensation in both C1- and C2-type, except for the apical 2 mm section of C1-type, suggesting the need for a modified CW technique.
format Online
Article
Text
id pubmed-6871781
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-68717812019-12-08 Comparison of continuous wave and cold lateral condensation filling techniques in 3D printed simulated C-shape canals instrumented with Reciproc Blue or Hyflex EDM Karatekin, Anıl Özgün Keleş, Ali Gençoğlu, Nimet PLoS One Research Article AIM: To compare the efficiency of continuous wave obturation and cold lateral condensation techniques and filling time in C-shape canals of 3-dimensional (3D)-printed resin teeth shaped with Reciproc Blue (VDW) or Hyflex EDM (Coltene/Whaledent). METHODOLOGY: One tooth with C1-type orifice and root canal morphology and one with C2-type orifice and C2-C3 root canal morphology were selected based on CBCT. Two replicas of selected teeth were manufactured with a 3D-printer and their canals were instrumented with Reciproc Blue or Hyflex EDM. These 4 instrumented replicas were scanned with CBCT. Identical 10 replicas of each group (total of 40) were produced using a 3D-printer and randomly divided into 2 groups (n = 5), root filled with either continuous wave obturation (CW) or cold lateral condensation (LC). Horizontal cross-sections of C1-type were made at 2, 4, 6, 8 mm and C2-type at 2, 4, 6 mm from the apical foramen. Gutta-percha, sealer and void areas were evaluated with image analysis sofware. Data were analysed using nonparametric Kruskal-Wallis and Mann Whitney-U tests and the Factorial ANOVA was used for interaction effects. Time required to fill canals was evaluated using the Mann-Whitney U test. RESULTS: For C1-type, LC had more gutta-percha and less sealer compared to CW in 2-mm sections (p<0.05). CW had greater percentages of gutta-percha and lower percentages of sealer compared with LC group in 4, 6, 8 mm sections and total area (p<0.05). LC group had higher percentages of voids compared to CW group in 2 and 4 mm sections (p<0.05). For C2-type, CW had more gutta-percha and less sealer versus LC group in all sections and total area (p<0.05). LC had the least gutta-percha and greatest sealer percentages at 6-mm sections (p<0.05). There was no statistically significant difference in the percentages of voids at any level of sections between the filling techniques (p>0.05). In both C-types, there was no significant difference in the percentages of gutta-percha, sealer and voids between Reciproc Blue and Hyflex EDM-shaped groups at any level (p>0.05). Time spent for the LC technique and filling C1-type was significantly longer than when using the CW technique and filling C2-type (p<0.05). CONCLUSIONS: Continuous wave obturation was more effective than lateral condensation in both C1- and C2-type, except for the apical 2 mm section of C1-type, suggesting the need for a modified CW technique. Public Library of Science 2019-11-21 /pmc/articles/PMC6871781/ /pubmed/31751375 http://dx.doi.org/10.1371/journal.pone.0224793 Text en © 2019 Karatekin et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Karatekin, Anıl Özgün
Keleş, Ali
Gençoğlu, Nimet
Comparison of continuous wave and cold lateral condensation filling techniques in 3D printed simulated C-shape canals instrumented with Reciproc Blue or Hyflex EDM
title Comparison of continuous wave and cold lateral condensation filling techniques in 3D printed simulated C-shape canals instrumented with Reciproc Blue or Hyflex EDM
title_full Comparison of continuous wave and cold lateral condensation filling techniques in 3D printed simulated C-shape canals instrumented with Reciproc Blue or Hyflex EDM
title_fullStr Comparison of continuous wave and cold lateral condensation filling techniques in 3D printed simulated C-shape canals instrumented with Reciproc Blue or Hyflex EDM
title_full_unstemmed Comparison of continuous wave and cold lateral condensation filling techniques in 3D printed simulated C-shape canals instrumented with Reciproc Blue or Hyflex EDM
title_short Comparison of continuous wave and cold lateral condensation filling techniques in 3D printed simulated C-shape canals instrumented with Reciproc Blue or Hyflex EDM
title_sort comparison of continuous wave and cold lateral condensation filling techniques in 3d printed simulated c-shape canals instrumented with reciproc blue or hyflex edm
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6871781/
https://www.ncbi.nlm.nih.gov/pubmed/31751375
http://dx.doi.org/10.1371/journal.pone.0224793
work_keys_str_mv AT karatekinanılozgun comparisonofcontinuouswaveandcoldlateralcondensationfillingtechniquesin3dprintedsimulatedcshapecanalsinstrumentedwithreciprocblueorhyflexedm
AT kelesali comparisonofcontinuouswaveandcoldlateralcondensationfillingtechniquesin3dprintedsimulatedcshapecanalsinstrumentedwithreciprocblueorhyflexedm
AT gencoglunimet comparisonofcontinuouswaveandcoldlateralcondensationfillingtechniquesin3dprintedsimulatedcshapecanalsinstrumentedwithreciprocblueorhyflexedm