Cargando…
Radiation Exposure from Fluoroscopy during Hip Arthroscopy
Objective Hip arthroscopy for femoroacetabular impingement treatment is a procedure that is not exempted from complications. The most common complications are related to the arthroscopic portals and the traction system. The use of fluoroscopy helps in hip arthroscopy; however, the radiation exposur...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Thieme Medical Publishers
2019
|
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6872459/ https://www.ncbi.nlm.nih.gov/pubmed/31763460 http://dx.doi.org/10.1055/s-0039-3400278 |
_version_ | 1783472492813221888 |
---|---|
author | Seijas, Roberto Català, Jordi Cepas, Miguel Ángel Sallent, Andrea Ares, Oscar Barastegui, David |
author_facet | Seijas, Roberto Català, Jordi Cepas, Miguel Ángel Sallent, Andrea Ares, Oscar Barastegui, David |
author_sort | Seijas, Roberto |
collection | PubMed |
description | Objective Hip arthroscopy for femoroacetabular impingement treatment is a procedure that is not exempted from complications. The most common complications are related to the arthroscopic portals and the traction system. The use of fluoroscopy helps in hip arthroscopy; however, the radiation exposure is a risk that has not yet been studied. Materials and Methods A retrospective study with 100 arthroscopies was performed. Surgical indication in all cases was femoroacetabular impingement. Surgical times and radiation exposure during the procedure had been recorded and reviewed for the present study. Results A mean of 138.20 cGy cm (2) radiation exposures was observed per patient and procedure for a mean time of radiation exposure of 0.36 minutes. These values are much lower than the values described as being at risk by the nuclear security commissions. Conclusions Radiation exposure in a hip arthroscopy due to femoroacetabular impingement is in margins well below the limits at risk for the patient. |
format | Online Article Text |
id | pubmed-6872459 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Thieme Medical Publishers |
record_format | MEDLINE/PubMed |
spelling | pubmed-68724592019-11-22 Radiation Exposure from Fluoroscopy during Hip Arthroscopy Seijas, Roberto Català, Jordi Cepas, Miguel Ángel Sallent, Andrea Ares, Oscar Barastegui, David Surg J (N Y) Objective Hip arthroscopy for femoroacetabular impingement treatment is a procedure that is not exempted from complications. The most common complications are related to the arthroscopic portals and the traction system. The use of fluoroscopy helps in hip arthroscopy; however, the radiation exposure is a risk that has not yet been studied. Materials and Methods A retrospective study with 100 arthroscopies was performed. Surgical indication in all cases was femoroacetabular impingement. Surgical times and radiation exposure during the procedure had been recorded and reviewed for the present study. Results A mean of 138.20 cGy cm (2) radiation exposures was observed per patient and procedure for a mean time of radiation exposure of 0.36 minutes. These values are much lower than the values described as being at risk by the nuclear security commissions. Conclusions Radiation exposure in a hip arthroscopy due to femoroacetabular impingement is in margins well below the limits at risk for the patient. Thieme Medical Publishers 2019-11-21 /pmc/articles/PMC6872459/ /pubmed/31763460 http://dx.doi.org/10.1055/s-0039-3400278 Text en https://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Seijas, Roberto Català, Jordi Cepas, Miguel Ángel Sallent, Andrea Ares, Oscar Barastegui, David Radiation Exposure from Fluoroscopy during Hip Arthroscopy |
title | Radiation Exposure from Fluoroscopy during Hip Arthroscopy |
title_full | Radiation Exposure from Fluoroscopy during Hip Arthroscopy |
title_fullStr | Radiation Exposure from Fluoroscopy during Hip Arthroscopy |
title_full_unstemmed | Radiation Exposure from Fluoroscopy during Hip Arthroscopy |
title_short | Radiation Exposure from Fluoroscopy during Hip Arthroscopy |
title_sort | radiation exposure from fluoroscopy during hip arthroscopy |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6872459/ https://www.ncbi.nlm.nih.gov/pubmed/31763460 http://dx.doi.org/10.1055/s-0039-3400278 |
work_keys_str_mv | AT seijasroberto radiationexposurefromfluoroscopyduringhiparthroscopy AT catalajordi radiationexposurefromfluoroscopyduringhiparthroscopy AT cepasmiguelangel radiationexposurefromfluoroscopyduringhiparthroscopy AT sallentandrea radiationexposurefromfluoroscopyduringhiparthroscopy AT aresoscar radiationexposurefromfluoroscopyduringhiparthroscopy AT barasteguidavid radiationexposurefromfluoroscopyduringhiparthroscopy |