Cargando…

The Role of Wettability on the Response of a Quartz Crystal Microbalance Loaded with a Sessile Droplet

In this work, the interaction between a sessile droplet’s contact angle and a quartz crystal microbalance (QCM) is elucidated. We differentiate the QCM’s frequency response to changes in the droplet contact area from variations in the dynamic contact angle. This is done by developing a computational...

Descripción completa

Detalles Bibliográficos
Autores principales: Murray, Brandon, Narayanan, Shankar
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6872598/
https://www.ncbi.nlm.nih.gov/pubmed/31754259
http://dx.doi.org/10.1038/s41598-019-53233-y
_version_ 1783472519384137728
author Murray, Brandon
Narayanan, Shankar
author_facet Murray, Brandon
Narayanan, Shankar
author_sort Murray, Brandon
collection PubMed
description In this work, the interaction between a sessile droplet’s contact angle and a quartz crystal microbalance (QCM) is elucidated. We differentiate the QCM’s frequency response to changes in the droplet contact area from variations in the dynamic contact angle. This is done by developing a computational model that couples the electrical and mechanical analysis of the quartz substrate with the visco-acoustic behavior of the sessile droplet. From our analysis, we conclude that changes in the contact angle have an effect on the frequency response of the QCM when the droplet height is on the order of the viscous decay length or smaller. On the other hand, changes in the interfacial contact area of the sessile droplets have a significant impact on the frequency response of the QCM regardless of the droplet size.
format Online
Article
Text
id pubmed-6872598
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-68725982019-12-04 The Role of Wettability on the Response of a Quartz Crystal Microbalance Loaded with a Sessile Droplet Murray, Brandon Narayanan, Shankar Sci Rep Article In this work, the interaction between a sessile droplet’s contact angle and a quartz crystal microbalance (QCM) is elucidated. We differentiate the QCM’s frequency response to changes in the droplet contact area from variations in the dynamic contact angle. This is done by developing a computational model that couples the electrical and mechanical analysis of the quartz substrate with the visco-acoustic behavior of the sessile droplet. From our analysis, we conclude that changes in the contact angle have an effect on the frequency response of the QCM when the droplet height is on the order of the viscous decay length or smaller. On the other hand, changes in the interfacial contact area of the sessile droplets have a significant impact on the frequency response of the QCM regardless of the droplet size. Nature Publishing Group UK 2019-11-21 /pmc/articles/PMC6872598/ /pubmed/31754259 http://dx.doi.org/10.1038/s41598-019-53233-y Text en © The Author(s) 2019 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Article
Murray, Brandon
Narayanan, Shankar
The Role of Wettability on the Response of a Quartz Crystal Microbalance Loaded with a Sessile Droplet
title The Role of Wettability on the Response of a Quartz Crystal Microbalance Loaded with a Sessile Droplet
title_full The Role of Wettability on the Response of a Quartz Crystal Microbalance Loaded with a Sessile Droplet
title_fullStr The Role of Wettability on the Response of a Quartz Crystal Microbalance Loaded with a Sessile Droplet
title_full_unstemmed The Role of Wettability on the Response of a Quartz Crystal Microbalance Loaded with a Sessile Droplet
title_short The Role of Wettability on the Response of a Quartz Crystal Microbalance Loaded with a Sessile Droplet
title_sort role of wettability on the response of a quartz crystal microbalance loaded with a sessile droplet
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6872598/
https://www.ncbi.nlm.nih.gov/pubmed/31754259
http://dx.doi.org/10.1038/s41598-019-53233-y
work_keys_str_mv AT murraybrandon theroleofwettabilityontheresponseofaquartzcrystalmicrobalanceloadedwithasessiledroplet
AT narayananshankar theroleofwettabilityontheresponseofaquartzcrystalmicrobalanceloadedwithasessiledroplet
AT murraybrandon roleofwettabilityontheresponseofaquartzcrystalmicrobalanceloadedwithasessiledroplet
AT narayananshankar roleofwettabilityontheresponseofaquartzcrystalmicrobalanceloadedwithasessiledroplet