Cargando…

Estimation of root inclination of anterior teeth from virtual study models: accuracy of a commercial software

BACKGROUND: The aim of the study was to assess the accuracy of commercially available software in estimating anterior tooth root inclination from digital impressions of the crowns of the teeth. SUBJECTS AND METHODS: Following sample size calculation and application of inclusion and exclusion criteri...

Descripción completa

Detalles Bibliográficos
Autores principales: Magkavali-Trikka, Panagiota, Halazonetis, Demetrios J., Athanasiou, Athanasios E.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6872682/
https://www.ncbi.nlm.nih.gov/pubmed/31754914
http://dx.doi.org/10.1186/s40510-019-0298-5
_version_ 1783472539113095168
author Magkavali-Trikka, Panagiota
Halazonetis, Demetrios J.
Athanasiou, Athanasios E.
author_facet Magkavali-Trikka, Panagiota
Halazonetis, Demetrios J.
Athanasiou, Athanasios E.
author_sort Magkavali-Trikka, Panagiota
collection PubMed
description BACKGROUND: The aim of the study was to assess the accuracy of commercially available software in estimating anterior tooth root inclination from digital impressions of the crowns of the teeth. SUBJECTS AND METHODS: Following sample size calculation and application of inclusion and exclusion criteria, 55 anterior natural teeth derived from 14 dry human skulls were selected. Impressions were taken and plaster study models were fabricated. Plaster models were scanned using the high-resolution mode of an Ortho Insight 3D laser scanner. The teeth on the digital scans were segmented and virtual roots were predicted and constructed by the Ortho Insight 3D software. The 55 natural teeth were removed from the dry skulls and scanned using the Identica extraoral white-light scanner in order to calculate their actual root angulation. The teeth were scanned twice, once to acquire the crown and the cervical part of the root, and a second time to acquire the remaining part of the root, including the apex. The two scanned segments were joined in software by superimposing them along their common part. The accuracy of the digital models generated by the Ortho Insight 3D scanner in predicting root angulation was assessed by comparing these results to the corresponding measurements of the 55 natural teeth. The long axes of the tooth models obtained from the software prediction and the scanning of the actual teeth were computed and the discrepancy between them was evaluated. The error of the methods was evaluated by repeating the measurements on 14 teeth and showed an acceptable range. RESULTS: The predicted tooth angulation was found to differ significantly from the actual angulation, both statistically and clinically. The angle between the predicted and actual long axes ranged from 2.0 to 37.6°(average 9.7°; median 7.4°). No statistically significant difference was found between tooth categories. CONCLUSIONS: Further investigations and improvements of the software are needed before it can be considered clinically effective.
format Online
Article
Text
id pubmed-6872682
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-68726822019-12-06 Estimation of root inclination of anterior teeth from virtual study models: accuracy of a commercial software Magkavali-Trikka, Panagiota Halazonetis, Demetrios J. Athanasiou, Athanasios E. Prog Orthod Research BACKGROUND: The aim of the study was to assess the accuracy of commercially available software in estimating anterior tooth root inclination from digital impressions of the crowns of the teeth. SUBJECTS AND METHODS: Following sample size calculation and application of inclusion and exclusion criteria, 55 anterior natural teeth derived from 14 dry human skulls were selected. Impressions were taken and plaster study models were fabricated. Plaster models were scanned using the high-resolution mode of an Ortho Insight 3D laser scanner. The teeth on the digital scans were segmented and virtual roots were predicted and constructed by the Ortho Insight 3D software. The 55 natural teeth were removed from the dry skulls and scanned using the Identica extraoral white-light scanner in order to calculate their actual root angulation. The teeth were scanned twice, once to acquire the crown and the cervical part of the root, and a second time to acquire the remaining part of the root, including the apex. The two scanned segments were joined in software by superimposing them along their common part. The accuracy of the digital models generated by the Ortho Insight 3D scanner in predicting root angulation was assessed by comparing these results to the corresponding measurements of the 55 natural teeth. The long axes of the tooth models obtained from the software prediction and the scanning of the actual teeth were computed and the discrepancy between them was evaluated. The error of the methods was evaluated by repeating the measurements on 14 teeth and showed an acceptable range. RESULTS: The predicted tooth angulation was found to differ significantly from the actual angulation, both statistically and clinically. The angle between the predicted and actual long axes ranged from 2.0 to 37.6°(average 9.7°; median 7.4°). No statistically significant difference was found between tooth categories. CONCLUSIONS: Further investigations and improvements of the software are needed before it can be considered clinically effective. Springer Berlin Heidelberg 2019-11-22 /pmc/articles/PMC6872682/ /pubmed/31754914 http://dx.doi.org/10.1186/s40510-019-0298-5 Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Research
Magkavali-Trikka, Panagiota
Halazonetis, Demetrios J.
Athanasiou, Athanasios E.
Estimation of root inclination of anterior teeth from virtual study models: accuracy of a commercial software
title Estimation of root inclination of anterior teeth from virtual study models: accuracy of a commercial software
title_full Estimation of root inclination of anterior teeth from virtual study models: accuracy of a commercial software
title_fullStr Estimation of root inclination of anterior teeth from virtual study models: accuracy of a commercial software
title_full_unstemmed Estimation of root inclination of anterior teeth from virtual study models: accuracy of a commercial software
title_short Estimation of root inclination of anterior teeth from virtual study models: accuracy of a commercial software
title_sort estimation of root inclination of anterior teeth from virtual study models: accuracy of a commercial software
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6872682/
https://www.ncbi.nlm.nih.gov/pubmed/31754914
http://dx.doi.org/10.1186/s40510-019-0298-5
work_keys_str_mv AT magkavalitrikkapanagiota estimationofrootinclinationofanteriorteethfromvirtualstudymodelsaccuracyofacommercialsoftware
AT halazonetisdemetriosj estimationofrootinclinationofanteriorteethfromvirtualstudymodelsaccuracyofacommercialsoftware
AT athanasiouathanasiose estimationofrootinclinationofanteriorteethfromvirtualstudymodelsaccuracyofacommercialsoftware