Cargando…

Accuracy of two electronic apex locators in locating root perforations in curved canals in dry and wet conditions: A comparative in vitro study

BACKGROUND: The aim of the study was to evaluate the accuracy of iPex and Vdw gold apex locators in detecting simulated root perforations in curved canals in the presence of 3% sodium hypochlorite (NaOCl) and 2% chlorhexidine (CHX). MATERIALS AND METHODS: In this comparative in vitro study Twenty ma...

Descripción completa

Detalles Bibliográficos
Autores principales: Khatri, Monisha Parshotam, Ghivari, Sheetal B., Pujar, Madhu, Faras, Reshma, Gopeshetti, Pallavi, Vanti, Amulya
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6873239/
https://www.ncbi.nlm.nih.gov/pubmed/31803387
_version_ 1783472625530437632
author Khatri, Monisha Parshotam
Ghivari, Sheetal B.
Pujar, Madhu
Faras, Reshma
Gopeshetti, Pallavi
Vanti, Amulya
author_facet Khatri, Monisha Parshotam
Ghivari, Sheetal B.
Pujar, Madhu
Faras, Reshma
Gopeshetti, Pallavi
Vanti, Amulya
author_sort Khatri, Monisha Parshotam
collection PubMed
description BACKGROUND: The aim of the study was to evaluate the accuracy of iPex and Vdw gold apex locators in detecting simulated root perforations in curved canals in the presence of 3% sodium hypochlorite (NaOCl) and 2% chlorhexidine (CHX). MATERIALS AND METHODS: In this comparative in vitro study Twenty mandibular molars with curved mesial roots were selected and perforation was made in the danger zone 4 mm from the furcation area. The actual length of the perforation site was measured using stereomicroscope software using a #15 K file, following which the teeth were embedded in alginate molds. The perforation site was electronically measured using two apex locators, iPex and Vdw gold in dry condition and in the presence of 3% NaOCl and 2% CHX. The values obtained were compared using the Friedman and Wilcoxon signed-rank test with level of statistical significance set at P ≤ 0.05. RESULTS: In dry condition, Vdw gold showed near accurate values, i.e., 0.25 mm from the manual value whereas iPex showed a significant difference (P < 0.05) of 0.76 mm from the manual value. In the presence of 3% NaOCl, both the apex locators showed a significant difference (P < 0.05) from the manual value with iPex showing a difference of 0.70 mm and Vdw gold showing a difference of 0.74 mm. The most accurate values were determined by both the apex locators in the presence of 2% CHX with iPex showing a deviation of 0.13 mm and Vdw gold showing a deviation of 0.39 mm from the manual. CONCLUSION: In dry condition, Vdw group showed better results than iPex in determining the length of the root perforation. In wet condition, in the presence of 2% CHX, both the apex locators accurately measured the perforation site, whereas in the presence of 3% NaOCl, both the apex locators showed a significant difference (P < 0.05) from the manual value in detecting the root perforation.
format Online
Article
Text
id pubmed-6873239
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-68732392019-12-04 Accuracy of two electronic apex locators in locating root perforations in curved canals in dry and wet conditions: A comparative in vitro study Khatri, Monisha Parshotam Ghivari, Sheetal B. Pujar, Madhu Faras, Reshma Gopeshetti, Pallavi Vanti, Amulya Dent Res J (Isfahan) Original Article BACKGROUND: The aim of the study was to evaluate the accuracy of iPex and Vdw gold apex locators in detecting simulated root perforations in curved canals in the presence of 3% sodium hypochlorite (NaOCl) and 2% chlorhexidine (CHX). MATERIALS AND METHODS: In this comparative in vitro study Twenty mandibular molars with curved mesial roots were selected and perforation was made in the danger zone 4 mm from the furcation area. The actual length of the perforation site was measured using stereomicroscope software using a #15 K file, following which the teeth were embedded in alginate molds. The perforation site was electronically measured using two apex locators, iPex and Vdw gold in dry condition and in the presence of 3% NaOCl and 2% CHX. The values obtained were compared using the Friedman and Wilcoxon signed-rank test with level of statistical significance set at P ≤ 0.05. RESULTS: In dry condition, Vdw gold showed near accurate values, i.e., 0.25 mm from the manual value whereas iPex showed a significant difference (P < 0.05) of 0.76 mm from the manual value. In the presence of 3% NaOCl, both the apex locators showed a significant difference (P < 0.05) from the manual value with iPex showing a difference of 0.70 mm and Vdw gold showing a difference of 0.74 mm. The most accurate values were determined by both the apex locators in the presence of 2% CHX with iPex showing a deviation of 0.13 mm and Vdw gold showing a deviation of 0.39 mm from the manual. CONCLUSION: In dry condition, Vdw group showed better results than iPex in determining the length of the root perforation. In wet condition, in the presence of 2% CHX, both the apex locators accurately measured the perforation site, whereas in the presence of 3% NaOCl, both the apex locators showed a significant difference (P < 0.05) from the manual value in detecting the root perforation. Wolters Kluwer - Medknow 2019-11-12 /pmc/articles/PMC6873239/ /pubmed/31803387 Text en Copyright: © 2019 Dental Research Journal http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Khatri, Monisha Parshotam
Ghivari, Sheetal B.
Pujar, Madhu
Faras, Reshma
Gopeshetti, Pallavi
Vanti, Amulya
Accuracy of two electronic apex locators in locating root perforations in curved canals in dry and wet conditions: A comparative in vitro study
title Accuracy of two electronic apex locators in locating root perforations in curved canals in dry and wet conditions: A comparative in vitro study
title_full Accuracy of two electronic apex locators in locating root perforations in curved canals in dry and wet conditions: A comparative in vitro study
title_fullStr Accuracy of two electronic apex locators in locating root perforations in curved canals in dry and wet conditions: A comparative in vitro study
title_full_unstemmed Accuracy of two electronic apex locators in locating root perforations in curved canals in dry and wet conditions: A comparative in vitro study
title_short Accuracy of two electronic apex locators in locating root perforations in curved canals in dry and wet conditions: A comparative in vitro study
title_sort accuracy of two electronic apex locators in locating root perforations in curved canals in dry and wet conditions: a comparative in vitro study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6873239/
https://www.ncbi.nlm.nih.gov/pubmed/31803387
work_keys_str_mv AT khatrimonishaparshotam accuracyoftwoelectronicapexlocatorsinlocatingrootperforationsincurvedcanalsindryandwetconditionsacomparativeinvitrostudy
AT ghivarisheetalb accuracyoftwoelectronicapexlocatorsinlocatingrootperforationsincurvedcanalsindryandwetconditionsacomparativeinvitrostudy
AT pujarmadhu accuracyoftwoelectronicapexlocatorsinlocatingrootperforationsincurvedcanalsindryandwetconditionsacomparativeinvitrostudy
AT farasreshma accuracyoftwoelectronicapexlocatorsinlocatingrootperforationsincurvedcanalsindryandwetconditionsacomparativeinvitrostudy
AT gopeshettipallavi accuracyoftwoelectronicapexlocatorsinlocatingrootperforationsincurvedcanalsindryandwetconditionsacomparativeinvitrostudy
AT vantiamulya accuracyoftwoelectronicapexlocatorsinlocatingrootperforationsincurvedcanalsindryandwetconditionsacomparativeinvitrostudy