Cargando…
Accuracy of two electronic apex locators in locating root perforations in curved canals in dry and wet conditions: A comparative in vitro study
BACKGROUND: The aim of the study was to evaluate the accuracy of iPex and Vdw gold apex locators in detecting simulated root perforations in curved canals in the presence of 3% sodium hypochlorite (NaOCl) and 2% chlorhexidine (CHX). MATERIALS AND METHODS: In this comparative in vitro study Twenty ma...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6873239/ https://www.ncbi.nlm.nih.gov/pubmed/31803387 |
_version_ | 1783472625530437632 |
---|---|
author | Khatri, Monisha Parshotam Ghivari, Sheetal B. Pujar, Madhu Faras, Reshma Gopeshetti, Pallavi Vanti, Amulya |
author_facet | Khatri, Monisha Parshotam Ghivari, Sheetal B. Pujar, Madhu Faras, Reshma Gopeshetti, Pallavi Vanti, Amulya |
author_sort | Khatri, Monisha Parshotam |
collection | PubMed |
description | BACKGROUND: The aim of the study was to evaluate the accuracy of iPex and Vdw gold apex locators in detecting simulated root perforations in curved canals in the presence of 3% sodium hypochlorite (NaOCl) and 2% chlorhexidine (CHX). MATERIALS AND METHODS: In this comparative in vitro study Twenty mandibular molars with curved mesial roots were selected and perforation was made in the danger zone 4 mm from the furcation area. The actual length of the perforation site was measured using stereomicroscope software using a #15 K file, following which the teeth were embedded in alginate molds. The perforation site was electronically measured using two apex locators, iPex and Vdw gold in dry condition and in the presence of 3% NaOCl and 2% CHX. The values obtained were compared using the Friedman and Wilcoxon signed-rank test with level of statistical significance set at P ≤ 0.05. RESULTS: In dry condition, Vdw gold showed near accurate values, i.e., 0.25 mm from the manual value whereas iPex showed a significant difference (P < 0.05) of 0.76 mm from the manual value. In the presence of 3% NaOCl, both the apex locators showed a significant difference (P < 0.05) from the manual value with iPex showing a difference of 0.70 mm and Vdw gold showing a difference of 0.74 mm. The most accurate values were determined by both the apex locators in the presence of 2% CHX with iPex showing a deviation of 0.13 mm and Vdw gold showing a deviation of 0.39 mm from the manual. CONCLUSION: In dry condition, Vdw group showed better results than iPex in determining the length of the root perforation. In wet condition, in the presence of 2% CHX, both the apex locators accurately measured the perforation site, whereas in the presence of 3% NaOCl, both the apex locators showed a significant difference (P < 0.05) from the manual value in detecting the root perforation. |
format | Online Article Text |
id | pubmed-6873239 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-68732392019-12-04 Accuracy of two electronic apex locators in locating root perforations in curved canals in dry and wet conditions: A comparative in vitro study Khatri, Monisha Parshotam Ghivari, Sheetal B. Pujar, Madhu Faras, Reshma Gopeshetti, Pallavi Vanti, Amulya Dent Res J (Isfahan) Original Article BACKGROUND: The aim of the study was to evaluate the accuracy of iPex and Vdw gold apex locators in detecting simulated root perforations in curved canals in the presence of 3% sodium hypochlorite (NaOCl) and 2% chlorhexidine (CHX). MATERIALS AND METHODS: In this comparative in vitro study Twenty mandibular molars with curved mesial roots were selected and perforation was made in the danger zone 4 mm from the furcation area. The actual length of the perforation site was measured using stereomicroscope software using a #15 K file, following which the teeth were embedded in alginate molds. The perforation site was electronically measured using two apex locators, iPex and Vdw gold in dry condition and in the presence of 3% NaOCl and 2% CHX. The values obtained were compared using the Friedman and Wilcoxon signed-rank test with level of statistical significance set at P ≤ 0.05. RESULTS: In dry condition, Vdw gold showed near accurate values, i.e., 0.25 mm from the manual value whereas iPex showed a significant difference (P < 0.05) of 0.76 mm from the manual value. In the presence of 3% NaOCl, both the apex locators showed a significant difference (P < 0.05) from the manual value with iPex showing a difference of 0.70 mm and Vdw gold showing a difference of 0.74 mm. The most accurate values were determined by both the apex locators in the presence of 2% CHX with iPex showing a deviation of 0.13 mm and Vdw gold showing a deviation of 0.39 mm from the manual. CONCLUSION: In dry condition, Vdw group showed better results than iPex in determining the length of the root perforation. In wet condition, in the presence of 2% CHX, both the apex locators accurately measured the perforation site, whereas in the presence of 3% NaOCl, both the apex locators showed a significant difference (P < 0.05) from the manual value in detecting the root perforation. Wolters Kluwer - Medknow 2019-11-12 /pmc/articles/PMC6873239/ /pubmed/31803387 Text en Copyright: © 2019 Dental Research Journal http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Khatri, Monisha Parshotam Ghivari, Sheetal B. Pujar, Madhu Faras, Reshma Gopeshetti, Pallavi Vanti, Amulya Accuracy of two electronic apex locators in locating root perforations in curved canals in dry and wet conditions: A comparative in vitro study |
title | Accuracy of two electronic apex locators in locating root perforations in curved canals in dry and wet conditions: A comparative in vitro study |
title_full | Accuracy of two electronic apex locators in locating root perforations in curved canals in dry and wet conditions: A comparative in vitro study |
title_fullStr | Accuracy of two electronic apex locators in locating root perforations in curved canals in dry and wet conditions: A comparative in vitro study |
title_full_unstemmed | Accuracy of two electronic apex locators in locating root perforations in curved canals in dry and wet conditions: A comparative in vitro study |
title_short | Accuracy of two electronic apex locators in locating root perforations in curved canals in dry and wet conditions: A comparative in vitro study |
title_sort | accuracy of two electronic apex locators in locating root perforations in curved canals in dry and wet conditions: a comparative in vitro study |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6873239/ https://www.ncbi.nlm.nih.gov/pubmed/31803387 |
work_keys_str_mv | AT khatrimonishaparshotam accuracyoftwoelectronicapexlocatorsinlocatingrootperforationsincurvedcanalsindryandwetconditionsacomparativeinvitrostudy AT ghivarisheetalb accuracyoftwoelectronicapexlocatorsinlocatingrootperforationsincurvedcanalsindryandwetconditionsacomparativeinvitrostudy AT pujarmadhu accuracyoftwoelectronicapexlocatorsinlocatingrootperforationsincurvedcanalsindryandwetconditionsacomparativeinvitrostudy AT farasreshma accuracyoftwoelectronicapexlocatorsinlocatingrootperforationsincurvedcanalsindryandwetconditionsacomparativeinvitrostudy AT gopeshettipallavi accuracyoftwoelectronicapexlocatorsinlocatingrootperforationsincurvedcanalsindryandwetconditionsacomparativeinvitrostudy AT vantiamulya accuracyoftwoelectronicapexlocatorsinlocatingrootperforationsincurvedcanalsindryandwetconditionsacomparativeinvitrostudy |