Cargando…

Polymer microchamber arrays for geometry-controlled drug release: a functional study in human cells of neuronal phenotype

Polyelectrolyte multilayer (PEM) microchambers can provide a versatile cargo delivery system enabling rapid, site-specific drug release on demand. However, experimental evidence for their potential benefits in live human cells is scarce. Equally, practical applications often require substance delive...

Descripción completa

Detalles Bibliográficos
Autores principales: Kopach, Olga, Zheng, Kayiu, Sindeeva, Olga A., Gai, Meiyu, Sukhorukov, Gleb B., Rusakov, Dmitri A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Royal Society of Chemistry 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6873774/
https://www.ncbi.nlm.nih.gov/pubmed/30916673
http://dx.doi.org/10.1039/c8bm01499j
_version_ 1783472734539350016
author Kopach, Olga
Zheng, Kayiu
Sindeeva, Olga A.
Gai, Meiyu
Sukhorukov, Gleb B.
Rusakov, Dmitri A.
author_facet Kopach, Olga
Zheng, Kayiu
Sindeeva, Olga A.
Gai, Meiyu
Sukhorukov, Gleb B.
Rusakov, Dmitri A.
author_sort Kopach, Olga
collection PubMed
description Polyelectrolyte multilayer (PEM) microchambers can provide a versatile cargo delivery system enabling rapid, site-specific drug release on demand. However, experimental evidence for their potential benefits in live human cells is scarce. Equally, practical applications often require substance delivery that is geometrically constrained and highly localized. Here, we establish human-cell biocompatibility and on-demand cargo release properties of the PEM or polylactic acid (PLA)-based microchamber arrays fabricated on a patterned film base. We grow human N2A cells (a neuroblastoma cell line widely used for studies of neurotoxicity) on the surface of the patterned microchamber arrays loaded with either a fluorescent indicator or the ubiquitous excitatory neurotransmitter glutamate. The differentiating human N2A cells show no detrimental effects on viability when growing on either PEM@PLA or PLA-based arrays for up to ten days in vitro. Firstly, we use two-photon (2P) excitation with femtosecond laser pulses to open individual microchambers in a controlled way while monitoring release and diffusion of the fluorescent cargo (rhodamine or FITC fluorescent dye). Secondly, we document the increases in intracellular Ca(2+) in local N2A cells in response to the laser-triggered glutamate release from individual microchambers. The functional cell response is site-specific and reproducible on demand and could be replicated by applying glutamate to the cells using a pressurised micropipette. Time-resolved fluorescence imaging confirms the physiological range of the glutamate-evoked intracellular Ca(2+) dynamics in the differentiating N2A cells. Our data indicate that the nano-engineering design of the fabricated PEM or PLA-based patterned microchamber arrays could provide a biologically safe and efficient tool for targeted, geometrically constrained drug delivery.
format Online
Article
Text
id pubmed-6873774
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Royal Society of Chemistry
record_format MEDLINE/PubMed
spelling pubmed-68737742019-12-09 Polymer microchamber arrays for geometry-controlled drug release: a functional study in human cells of neuronal phenotype Kopach, Olga Zheng, Kayiu Sindeeva, Olga A. Gai, Meiyu Sukhorukov, Gleb B. Rusakov, Dmitri A. Biomater Sci Chemistry Polyelectrolyte multilayer (PEM) microchambers can provide a versatile cargo delivery system enabling rapid, site-specific drug release on demand. However, experimental evidence for their potential benefits in live human cells is scarce. Equally, practical applications often require substance delivery that is geometrically constrained and highly localized. Here, we establish human-cell biocompatibility and on-demand cargo release properties of the PEM or polylactic acid (PLA)-based microchamber arrays fabricated on a patterned film base. We grow human N2A cells (a neuroblastoma cell line widely used for studies of neurotoxicity) on the surface of the patterned microchamber arrays loaded with either a fluorescent indicator or the ubiquitous excitatory neurotransmitter glutamate. The differentiating human N2A cells show no detrimental effects on viability when growing on either PEM@PLA or PLA-based arrays for up to ten days in vitro. Firstly, we use two-photon (2P) excitation with femtosecond laser pulses to open individual microchambers in a controlled way while monitoring release and diffusion of the fluorescent cargo (rhodamine or FITC fluorescent dye). Secondly, we document the increases in intracellular Ca(2+) in local N2A cells in response to the laser-triggered glutamate release from individual microchambers. The functional cell response is site-specific and reproducible on demand and could be replicated by applying glutamate to the cells using a pressurised micropipette. Time-resolved fluorescence imaging confirms the physiological range of the glutamate-evoked intracellular Ca(2+) dynamics in the differentiating N2A cells. Our data indicate that the nano-engineering design of the fabricated PEM or PLA-based patterned microchamber arrays could provide a biologically safe and efficient tool for targeted, geometrically constrained drug delivery. Royal Society of Chemistry 2019-06-01 2019-03-27 /pmc/articles/PMC6873774/ /pubmed/30916673 http://dx.doi.org/10.1039/c8bm01499j Text en This journal is © The Royal Society of Chemistry 2019 http://creativecommons.org/licenses/by/3.0/ This article is freely available. This article is licensed under a Creative Commons Attribution 3.0 Unported Licence (CC BY 3.0)
spellingShingle Chemistry
Kopach, Olga
Zheng, Kayiu
Sindeeva, Olga A.
Gai, Meiyu
Sukhorukov, Gleb B.
Rusakov, Dmitri A.
Polymer microchamber arrays for geometry-controlled drug release: a functional study in human cells of neuronal phenotype
title Polymer microchamber arrays for geometry-controlled drug release: a functional study in human cells of neuronal phenotype
title_full Polymer microchamber arrays for geometry-controlled drug release: a functional study in human cells of neuronal phenotype
title_fullStr Polymer microchamber arrays for geometry-controlled drug release: a functional study in human cells of neuronal phenotype
title_full_unstemmed Polymer microchamber arrays for geometry-controlled drug release: a functional study in human cells of neuronal phenotype
title_short Polymer microchamber arrays for geometry-controlled drug release: a functional study in human cells of neuronal phenotype
title_sort polymer microchamber arrays for geometry-controlled drug release: a functional study in human cells of neuronal phenotype
topic Chemistry
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6873774/
https://www.ncbi.nlm.nih.gov/pubmed/30916673
http://dx.doi.org/10.1039/c8bm01499j
work_keys_str_mv AT kopacholga polymermicrochamberarraysforgeometrycontrolleddrugreleaseafunctionalstudyinhumancellsofneuronalphenotype
AT zhengkayiu polymermicrochamberarraysforgeometrycontrolleddrugreleaseafunctionalstudyinhumancellsofneuronalphenotype
AT sindeevaolgaa polymermicrochamberarraysforgeometrycontrolleddrugreleaseafunctionalstudyinhumancellsofneuronalphenotype
AT gaimeiyu polymermicrochamberarraysforgeometrycontrolleddrugreleaseafunctionalstudyinhumancellsofneuronalphenotype
AT sukhorukovglebb polymermicrochamberarraysforgeometrycontrolleddrugreleaseafunctionalstudyinhumancellsofneuronalphenotype
AT rusakovdmitria polymermicrochamberarraysforgeometrycontrolleddrugreleaseafunctionalstudyinhumancellsofneuronalphenotype