Development and interlaboratory evaluation of a NIST Reference Material RM 8366 for EGFR and MET gene copy number measurements

BACKGROUND: The National Institute of Standards and Technology (NIST) Reference Material RM 8366 was developed to improve the quality of gene copy measurements of EGFR (epidermal growth factor receptor) and MET (proto-oncogene, receptor tyrosine kinase), important targets for cancer diagnostics and...

Descripción completa

Detalles Bibliográficos
Autores principales: He, Hua-Jun, Das, Biswajit, Cleveland, Megan H., Chen, Li, Camalier, Corinne E., Liu, Liang-Chun, Norman, Kara L., Fellowes, Andrew P., McEvoy, Christopher R., Lund, Steve P., Almeida, Jamie, Steffen, Carolyn R., Karlovich, Chris, Williams, P. Mickey, Cole, Kenneth D.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6875440/
https://www.ncbi.nlm.nih.gov/pubmed/31112502
http://dx.doi.org/10.1515/cclm-2018-1306
_version_ 1783473031101808640
author He, Hua-Jun
Das, Biswajit
Cleveland, Megan H.
Chen, Li
Camalier, Corinne E.
Liu, Liang-Chun
Norman, Kara L.
Fellowes, Andrew P.
McEvoy, Christopher R.
Lund, Steve P.
Almeida, Jamie
Steffen, Carolyn R.
Karlovich, Chris
Williams, P. Mickey
Cole, Kenneth D.
author_facet He, Hua-Jun
Das, Biswajit
Cleveland, Megan H.
Chen, Li
Camalier, Corinne E.
Liu, Liang-Chun
Norman, Kara L.
Fellowes, Andrew P.
McEvoy, Christopher R.
Lund, Steve P.
Almeida, Jamie
Steffen, Carolyn R.
Karlovich, Chris
Williams, P. Mickey
Cole, Kenneth D.
author_sort He, Hua-Jun
collection PubMed
description BACKGROUND: The National Institute of Standards and Technology (NIST) Reference Material RM 8366 was developed to improve the quality of gene copy measurements of EGFR (epidermal growth factor receptor) and MET (proto-oncogene, receptor tyrosine kinase), important targets for cancer diagnostics and treatment. The reference material is composed of genomic DNA prepared from six human cancer cell lines with different levels of amplification of the target genes. METHODS: The reference values for the ratios of the EGFR and MET gene copy numbers to the copy numbers of reference genes were measured using digital PCR. The digital PCR measurements were confirmed by two additional laboratories. The samples were also characterized using Next Generation Sequencing (NGS) methods including whole genome sequencing (WGS) at three levels of coverage (approximately 1 ×, 5 × and greater than 30 ×), whole exome sequencing (WES), and two different pan-cancer gene panels. The WES data were analyzed using three different bioinformatic algorithms. RESULTS: The certified values (digital PCR) for EGFR and MET were in good agreement (within 20%) with the values obtained from the different NGS methods and algorithms for five of the six components; one component had lower NGS values. CONCLUSIONS: This study shows that NIST RM 8366 is a valuable reference material to evaluate the performance of assays that assess EGFR and MET gene copy number measurements.
format Online
Article
Text
id pubmed-6875440
institution National Center for Biotechnology Information
language English
publishDate 2019
record_format MEDLINE/PubMed
spelling pubmed-68754402020-07-26 Development and interlaboratory evaluation of a NIST Reference Material RM 8366 for EGFR and MET gene copy number measurements He, Hua-Jun Das, Biswajit Cleveland, Megan H. Chen, Li Camalier, Corinne E. Liu, Liang-Chun Norman, Kara L. Fellowes, Andrew P. McEvoy, Christopher R. Lund, Steve P. Almeida, Jamie Steffen, Carolyn R. Karlovich, Chris Williams, P. Mickey Cole, Kenneth D. Clin Chem Lab Med Article BACKGROUND: The National Institute of Standards and Technology (NIST) Reference Material RM 8366 was developed to improve the quality of gene copy measurements of EGFR (epidermal growth factor receptor) and MET (proto-oncogene, receptor tyrosine kinase), important targets for cancer diagnostics and treatment. The reference material is composed of genomic DNA prepared from six human cancer cell lines with different levels of amplification of the target genes. METHODS: The reference values for the ratios of the EGFR and MET gene copy numbers to the copy numbers of reference genes were measured using digital PCR. The digital PCR measurements were confirmed by two additional laboratories. The samples were also characterized using Next Generation Sequencing (NGS) methods including whole genome sequencing (WGS) at three levels of coverage (approximately 1 ×, 5 × and greater than 30 ×), whole exome sequencing (WES), and two different pan-cancer gene panels. The WES data were analyzed using three different bioinformatic algorithms. RESULTS: The certified values (digital PCR) for EGFR and MET were in good agreement (within 20%) with the values obtained from the different NGS methods and algorithms for five of the six components; one component had lower NGS values. CONCLUSIONS: This study shows that NIST RM 8366 is a valuable reference material to evaluate the performance of assays that assess EGFR and MET gene copy number measurements. 2019-07-26 /pmc/articles/PMC6875440/ /pubmed/31112502 http://dx.doi.org/10.1515/cclm-2018-1306 Text en This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 License http://creativecommons.org/licenses/by-nc-nd/4.0/.
spellingShingle Article
He, Hua-Jun
Das, Biswajit
Cleveland, Megan H.
Chen, Li
Camalier, Corinne E.
Liu, Liang-Chun
Norman, Kara L.
Fellowes, Andrew P.
McEvoy, Christopher R.
Lund, Steve P.
Almeida, Jamie
Steffen, Carolyn R.
Karlovich, Chris
Williams, P. Mickey
Cole, Kenneth D.
Development and interlaboratory evaluation of a NIST Reference Material RM 8366 for EGFR and MET gene copy number measurements
title Development and interlaboratory evaluation of a NIST Reference Material RM 8366 for EGFR and MET gene copy number measurements
title_full Development and interlaboratory evaluation of a NIST Reference Material RM 8366 for EGFR and MET gene copy number measurements
title_fullStr Development and interlaboratory evaluation of a NIST Reference Material RM 8366 for EGFR and MET gene copy number measurements
title_full_unstemmed Development and interlaboratory evaluation of a NIST Reference Material RM 8366 for EGFR and MET gene copy number measurements
title_short Development and interlaboratory evaluation of a NIST Reference Material RM 8366 for EGFR and MET gene copy number measurements
title_sort development and interlaboratory evaluation of a nist reference material rm 8366 for egfr and met gene copy number measurements
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6875440/
https://www.ncbi.nlm.nih.gov/pubmed/31112502
http://dx.doi.org/10.1515/cclm-2018-1306
work_keys_str_mv AT hehuajun developmentandinterlaboratoryevaluationofanistreferencematerialrm8366foregfrandmetgenecopynumbermeasurements
AT dasbiswajit developmentandinterlaboratoryevaluationofanistreferencematerialrm8366foregfrandmetgenecopynumbermeasurements
AT clevelandmeganh developmentandinterlaboratoryevaluationofanistreferencematerialrm8366foregfrandmetgenecopynumbermeasurements
AT chenli developmentandinterlaboratoryevaluationofanistreferencematerialrm8366foregfrandmetgenecopynumbermeasurements
AT camaliercorinnee developmentandinterlaboratoryevaluationofanistreferencematerialrm8366foregfrandmetgenecopynumbermeasurements
AT liuliangchun developmentandinterlaboratoryevaluationofanistreferencematerialrm8366foregfrandmetgenecopynumbermeasurements
AT normankaral developmentandinterlaboratoryevaluationofanistreferencematerialrm8366foregfrandmetgenecopynumbermeasurements
AT fellowesandrewp developmentandinterlaboratoryevaluationofanistreferencematerialrm8366foregfrandmetgenecopynumbermeasurements
AT mcevoychristopherr developmentandinterlaboratoryevaluationofanistreferencematerialrm8366foregfrandmetgenecopynumbermeasurements
AT lundstevep developmentandinterlaboratoryevaluationofanistreferencematerialrm8366foregfrandmetgenecopynumbermeasurements
AT almeidajamie developmentandinterlaboratoryevaluationofanistreferencematerialrm8366foregfrandmetgenecopynumbermeasurements
AT steffencarolynr developmentandinterlaboratoryevaluationofanistreferencematerialrm8366foregfrandmetgenecopynumbermeasurements
AT karlovichchris developmentandinterlaboratoryevaluationofanistreferencematerialrm8366foregfrandmetgenecopynumbermeasurements
AT williamspmickey developmentandinterlaboratoryevaluationofanistreferencematerialrm8366foregfrandmetgenecopynumbermeasurements
AT colekennethd developmentandinterlaboratoryevaluationofanistreferencematerialrm8366foregfrandmetgenecopynumbermeasurements