Cargando…
Development and interlaboratory evaluation of a NIST Reference Material RM 8366 for EGFR and MET gene copy number measurements
BACKGROUND: The National Institute of Standards and Technology (NIST) Reference Material RM 8366 was developed to improve the quality of gene copy measurements of EGFR (epidermal growth factor receptor) and MET (proto-oncogene, receptor tyrosine kinase), important targets for cancer diagnostics and...
Autores principales: | , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6875440/ https://www.ncbi.nlm.nih.gov/pubmed/31112502 http://dx.doi.org/10.1515/cclm-2018-1306 |
_version_ | 1783473031101808640 |
---|---|
author | He, Hua-Jun Das, Biswajit Cleveland, Megan H. Chen, Li Camalier, Corinne E. Liu, Liang-Chun Norman, Kara L. Fellowes, Andrew P. McEvoy, Christopher R. Lund, Steve P. Almeida, Jamie Steffen, Carolyn R. Karlovich, Chris Williams, P. Mickey Cole, Kenneth D. |
author_facet | He, Hua-Jun Das, Biswajit Cleveland, Megan H. Chen, Li Camalier, Corinne E. Liu, Liang-Chun Norman, Kara L. Fellowes, Andrew P. McEvoy, Christopher R. Lund, Steve P. Almeida, Jamie Steffen, Carolyn R. Karlovich, Chris Williams, P. Mickey Cole, Kenneth D. |
author_sort | He, Hua-Jun |
collection | PubMed |
description | BACKGROUND: The National Institute of Standards and Technology (NIST) Reference Material RM 8366 was developed to improve the quality of gene copy measurements of EGFR (epidermal growth factor receptor) and MET (proto-oncogene, receptor tyrosine kinase), important targets for cancer diagnostics and treatment. The reference material is composed of genomic DNA prepared from six human cancer cell lines with different levels of amplification of the target genes. METHODS: The reference values for the ratios of the EGFR and MET gene copy numbers to the copy numbers of reference genes were measured using digital PCR. The digital PCR measurements were confirmed by two additional laboratories. The samples were also characterized using Next Generation Sequencing (NGS) methods including whole genome sequencing (WGS) at three levels of coverage (approximately 1 ×, 5 × and greater than 30 ×), whole exome sequencing (WES), and two different pan-cancer gene panels. The WES data were analyzed using three different bioinformatic algorithms. RESULTS: The certified values (digital PCR) for EGFR and MET were in good agreement (within 20%) with the values obtained from the different NGS methods and algorithms for five of the six components; one component had lower NGS values. CONCLUSIONS: This study shows that NIST RM 8366 is a valuable reference material to evaluate the performance of assays that assess EGFR and MET gene copy number measurements. |
format | Online Article Text |
id | pubmed-6875440 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
record_format | MEDLINE/PubMed |
spelling | pubmed-68754402020-07-26 Development and interlaboratory evaluation of a NIST Reference Material RM 8366 for EGFR and MET gene copy number measurements He, Hua-Jun Das, Biswajit Cleveland, Megan H. Chen, Li Camalier, Corinne E. Liu, Liang-Chun Norman, Kara L. Fellowes, Andrew P. McEvoy, Christopher R. Lund, Steve P. Almeida, Jamie Steffen, Carolyn R. Karlovich, Chris Williams, P. Mickey Cole, Kenneth D. Clin Chem Lab Med Article BACKGROUND: The National Institute of Standards and Technology (NIST) Reference Material RM 8366 was developed to improve the quality of gene copy measurements of EGFR (epidermal growth factor receptor) and MET (proto-oncogene, receptor tyrosine kinase), important targets for cancer diagnostics and treatment. The reference material is composed of genomic DNA prepared from six human cancer cell lines with different levels of amplification of the target genes. METHODS: The reference values for the ratios of the EGFR and MET gene copy numbers to the copy numbers of reference genes were measured using digital PCR. The digital PCR measurements were confirmed by two additional laboratories. The samples were also characterized using Next Generation Sequencing (NGS) methods including whole genome sequencing (WGS) at three levels of coverage (approximately 1 ×, 5 × and greater than 30 ×), whole exome sequencing (WES), and two different pan-cancer gene panels. The WES data were analyzed using three different bioinformatic algorithms. RESULTS: The certified values (digital PCR) for EGFR and MET were in good agreement (within 20%) with the values obtained from the different NGS methods and algorithms for five of the six components; one component had lower NGS values. CONCLUSIONS: This study shows that NIST RM 8366 is a valuable reference material to evaluate the performance of assays that assess EGFR and MET gene copy number measurements. 2019-07-26 /pmc/articles/PMC6875440/ /pubmed/31112502 http://dx.doi.org/10.1515/cclm-2018-1306 Text en This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 License http://creativecommons.org/licenses/by-nc-nd/4.0/. |
spellingShingle | Article He, Hua-Jun Das, Biswajit Cleveland, Megan H. Chen, Li Camalier, Corinne E. Liu, Liang-Chun Norman, Kara L. Fellowes, Andrew P. McEvoy, Christopher R. Lund, Steve P. Almeida, Jamie Steffen, Carolyn R. Karlovich, Chris Williams, P. Mickey Cole, Kenneth D. Development and interlaboratory evaluation of a NIST Reference Material RM 8366 for EGFR and MET gene copy number measurements |
title | Development and interlaboratory evaluation of a NIST Reference Material RM 8366 for EGFR and MET gene copy number measurements |
title_full | Development and interlaboratory evaluation of a NIST Reference Material RM 8366 for EGFR and MET gene copy number measurements |
title_fullStr | Development and interlaboratory evaluation of a NIST Reference Material RM 8366 for EGFR and MET gene copy number measurements |
title_full_unstemmed | Development and interlaboratory evaluation of a NIST Reference Material RM 8366 for EGFR and MET gene copy number measurements |
title_short | Development and interlaboratory evaluation of a NIST Reference Material RM 8366 for EGFR and MET gene copy number measurements |
title_sort | development and interlaboratory evaluation of a nist reference material rm 8366 for egfr and met gene copy number measurements |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6875440/ https://www.ncbi.nlm.nih.gov/pubmed/31112502 http://dx.doi.org/10.1515/cclm-2018-1306 |
work_keys_str_mv | AT hehuajun developmentandinterlaboratoryevaluationofanistreferencematerialrm8366foregfrandmetgenecopynumbermeasurements AT dasbiswajit developmentandinterlaboratoryevaluationofanistreferencematerialrm8366foregfrandmetgenecopynumbermeasurements AT clevelandmeganh developmentandinterlaboratoryevaluationofanistreferencematerialrm8366foregfrandmetgenecopynumbermeasurements AT chenli developmentandinterlaboratoryevaluationofanistreferencematerialrm8366foregfrandmetgenecopynumbermeasurements AT camaliercorinnee developmentandinterlaboratoryevaluationofanistreferencematerialrm8366foregfrandmetgenecopynumbermeasurements AT liuliangchun developmentandinterlaboratoryevaluationofanistreferencematerialrm8366foregfrandmetgenecopynumbermeasurements AT normankaral developmentandinterlaboratoryevaluationofanistreferencematerialrm8366foregfrandmetgenecopynumbermeasurements AT fellowesandrewp developmentandinterlaboratoryevaluationofanistreferencematerialrm8366foregfrandmetgenecopynumbermeasurements AT mcevoychristopherr developmentandinterlaboratoryevaluationofanistreferencematerialrm8366foregfrandmetgenecopynumbermeasurements AT lundstevep developmentandinterlaboratoryevaluationofanistreferencematerialrm8366foregfrandmetgenecopynumbermeasurements AT almeidajamie developmentandinterlaboratoryevaluationofanistreferencematerialrm8366foregfrandmetgenecopynumbermeasurements AT steffencarolynr developmentandinterlaboratoryevaluationofanistreferencematerialrm8366foregfrandmetgenecopynumbermeasurements AT karlovichchris developmentandinterlaboratoryevaluationofanistreferencematerialrm8366foregfrandmetgenecopynumbermeasurements AT williamspmickey developmentandinterlaboratoryevaluationofanistreferencematerialrm8366foregfrandmetgenecopynumbermeasurements AT colekennethd developmentandinterlaboratoryevaluationofanistreferencematerialrm8366foregfrandmetgenecopynumbermeasurements |