Cargando…

Hemoglobin Video Imaging Provides Novel In Vivo High-Resolution Imaging and Quantification of Human Aqueous Outflow in Patients with Glaucoma

PURPOSE: Noninvasive, detailed measurement of the dynamics of human aqueous outflow is difficult to achieve with currently available clinical tools. We used hemoglobin video imaging (HVI) to develop a technique to image and quantify human aqueous outflow noninvasively and in real time. DESIGN: A pro...

Descripción completa

Detalles Bibliográficos
Autores principales: Khatib, Tasneem Z., Meyer, Paul A.R., Lusthaus, Jed, Manyakin, Ilya, Mushtaq, Yusuf, Martin, Keith R.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier Inc 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6876656/
https://www.ncbi.nlm.nih.gov/pubmed/31788668
http://dx.doi.org/10.1016/j.ogla.2019.04.001
_version_ 1783473240118657024
author Khatib, Tasneem Z.
Meyer, Paul A.R.
Lusthaus, Jed
Manyakin, Ilya
Mushtaq, Yusuf
Martin, Keith R.
author_facet Khatib, Tasneem Z.
Meyer, Paul A.R.
Lusthaus, Jed
Manyakin, Ilya
Mushtaq, Yusuf
Martin, Keith R.
author_sort Khatib, Tasneem Z.
collection PubMed
description PURPOSE: Noninvasive, detailed measurement of the dynamics of human aqueous outflow is difficult to achieve with currently available clinical tools. We used hemoglobin video imaging (HVI) to develop a technique to image and quantify human aqueous outflow noninvasively and in real time. DESIGN: A prospective observational study to describe characteristics of aqueous veins and a pilot prospective interventional feasibility study to develop quantification parameters. PARTICIPANTS: Patients were recruited from the Cambridge University Hospitals NHS Foundation Trust Glaucoma clinic. The observational study included 30 eyes, and the pilot interventional feasibility study was performed on 8 eyes undergoing selective laser trabeculoplasty (SLT). Our SLT protocol also included the installation of pilocarpine and apraclonidine eye drops. METHODS: Participants underwent HVI alongside their usual clinic visit. MAIN OUTCOME MEASURES: The change in cross-sectional area (CSA) of the aqueous column within episcleral veins was correlated with intraocular pressure (IOP) reduction and change in visual field mean deviation (MD) before and after intervention. Fluctuations in contrast and pixel intensity of red blood cells in an aqueous vein were calculated to compare the flow rate before and after intervention using autocorrelation analysis. RESULTS: Hemoglobin video imaging enables the direct observation of aqueous flow into the vascular system. Aqueous is seen to centralize within a laminar venous column. Flow is pulsatile, and fluctuations of flow through globe pressure or compression of the aqueous vein are observed. There was a significant increase in the aqueous column after the administration of our SLT protocol (n = 13; P < 0.05). This correlated with the degree of IOP reduction (n = 13; Pearson’s correlation coefficient 0.7; P = 0.007) and the improvement in MD observed postintervention (n = 8; Pearson’s correlation coefficient 0.75; P = 0.03). Autocorrelation analysis demonstrated a faster rate of decay in an aqueous vein after intervention, indicating an increase in flow rate. CONCLUSIONS: Hemoglobin video imaging can be incorporated into a routine clinic slit-lamp examination to allow a detailed assessment and quantification of aqueous outflow in real time. It has the potential to be used to help target therapeutic interventions to improve aqueous outflow and further advance our understanding of aqueous outflow dysregulation in the pathogenesis of glaucoma.
format Online
Article
Text
id pubmed-6876656
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Elsevier Inc
record_format MEDLINE/PubMed
spelling pubmed-68766562019-11-29 Hemoglobin Video Imaging Provides Novel In Vivo High-Resolution Imaging and Quantification of Human Aqueous Outflow in Patients with Glaucoma Khatib, Tasneem Z. Meyer, Paul A.R. Lusthaus, Jed Manyakin, Ilya Mushtaq, Yusuf Martin, Keith R. Ophthalmol Glaucoma Article PURPOSE: Noninvasive, detailed measurement of the dynamics of human aqueous outflow is difficult to achieve with currently available clinical tools. We used hemoglobin video imaging (HVI) to develop a technique to image and quantify human aqueous outflow noninvasively and in real time. DESIGN: A prospective observational study to describe characteristics of aqueous veins and a pilot prospective interventional feasibility study to develop quantification parameters. PARTICIPANTS: Patients were recruited from the Cambridge University Hospitals NHS Foundation Trust Glaucoma clinic. The observational study included 30 eyes, and the pilot interventional feasibility study was performed on 8 eyes undergoing selective laser trabeculoplasty (SLT). Our SLT protocol also included the installation of pilocarpine and apraclonidine eye drops. METHODS: Participants underwent HVI alongside their usual clinic visit. MAIN OUTCOME MEASURES: The change in cross-sectional area (CSA) of the aqueous column within episcleral veins was correlated with intraocular pressure (IOP) reduction and change in visual field mean deviation (MD) before and after intervention. Fluctuations in contrast and pixel intensity of red blood cells in an aqueous vein were calculated to compare the flow rate before and after intervention using autocorrelation analysis. RESULTS: Hemoglobin video imaging enables the direct observation of aqueous flow into the vascular system. Aqueous is seen to centralize within a laminar venous column. Flow is pulsatile, and fluctuations of flow through globe pressure or compression of the aqueous vein are observed. There was a significant increase in the aqueous column after the administration of our SLT protocol (n = 13; P < 0.05). This correlated with the degree of IOP reduction (n = 13; Pearson’s correlation coefficient 0.7; P = 0.007) and the improvement in MD observed postintervention (n = 8; Pearson’s correlation coefficient 0.75; P = 0.03). Autocorrelation analysis demonstrated a faster rate of decay in an aqueous vein after intervention, indicating an increase in flow rate. CONCLUSIONS: Hemoglobin video imaging can be incorporated into a routine clinic slit-lamp examination to allow a detailed assessment and quantification of aqueous outflow in real time. It has the potential to be used to help target therapeutic interventions to improve aqueous outflow and further advance our understanding of aqueous outflow dysregulation in the pathogenesis of glaucoma. Elsevier Inc 2019 /pmc/articles/PMC6876656/ /pubmed/31788668 http://dx.doi.org/10.1016/j.ogla.2019.04.001 Text en © 2019 by the American Academy of OphthalmologyThis is an open access article under the CC BY license (<inter-ref xlink: href=http://creativecommons.org/licenses/by/4.0/>http://creativecommons.org/licenses/by/4.0/</inter-ref>). http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Khatib, Tasneem Z.
Meyer, Paul A.R.
Lusthaus, Jed
Manyakin, Ilya
Mushtaq, Yusuf
Martin, Keith R.
Hemoglobin Video Imaging Provides Novel In Vivo High-Resolution Imaging and Quantification of Human Aqueous Outflow in Patients with Glaucoma
title Hemoglobin Video Imaging Provides Novel In Vivo High-Resolution Imaging and Quantification of Human Aqueous Outflow in Patients with Glaucoma
title_full Hemoglobin Video Imaging Provides Novel In Vivo High-Resolution Imaging and Quantification of Human Aqueous Outflow in Patients with Glaucoma
title_fullStr Hemoglobin Video Imaging Provides Novel In Vivo High-Resolution Imaging and Quantification of Human Aqueous Outflow in Patients with Glaucoma
title_full_unstemmed Hemoglobin Video Imaging Provides Novel In Vivo High-Resolution Imaging and Quantification of Human Aqueous Outflow in Patients with Glaucoma
title_short Hemoglobin Video Imaging Provides Novel In Vivo High-Resolution Imaging and Quantification of Human Aqueous Outflow in Patients with Glaucoma
title_sort hemoglobin video imaging provides novel in vivo high-resolution imaging and quantification of human aqueous outflow in patients with glaucoma
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6876656/
https://www.ncbi.nlm.nih.gov/pubmed/31788668
http://dx.doi.org/10.1016/j.ogla.2019.04.001
work_keys_str_mv AT khatibtasneemz hemoglobinvideoimagingprovidesnovelinvivohighresolutionimagingandquantificationofhumanaqueousoutflowinpatientswithglaucoma
AT meyerpaular hemoglobinvideoimagingprovidesnovelinvivohighresolutionimagingandquantificationofhumanaqueousoutflowinpatientswithglaucoma
AT lusthausjed hemoglobinvideoimagingprovidesnovelinvivohighresolutionimagingandquantificationofhumanaqueousoutflowinpatientswithglaucoma
AT manyakinilya hemoglobinvideoimagingprovidesnovelinvivohighresolutionimagingandquantificationofhumanaqueousoutflowinpatientswithglaucoma
AT mushtaqyusuf hemoglobinvideoimagingprovidesnovelinvivohighresolutionimagingandquantificationofhumanaqueousoutflowinpatientswithglaucoma
AT martinkeithr hemoglobinvideoimagingprovidesnovelinvivohighresolutionimagingandquantificationofhumanaqueousoutflowinpatientswithglaucoma