Cargando…

Phenomenological models of Na(V)1.5. A side by side, procedural, hands-on comparison between Hodgkin-Huxley and kinetic formalisms

Computational models of ion channels represent the building blocks of conductance-based, biologically inspired models of neurons and neural networks. Ion channels are still widely modelled by means of the formalism developed by the seminal work of Hodgkin and Huxley (HH), although the electrophysiol...

Descripción completa

Detalles Bibliográficos
Autores principales: Andreozzi, Emilio, Carannante, Ilaria, D’Addio, Giovanni, Cesarelli, Mario, Balbi, Pietro
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6877610/
https://www.ncbi.nlm.nih.gov/pubmed/31767896
http://dx.doi.org/10.1038/s41598-019-53662-9
_version_ 1783473368840798208
author Andreozzi, Emilio
Carannante, Ilaria
D’Addio, Giovanni
Cesarelli, Mario
Balbi, Pietro
author_facet Andreozzi, Emilio
Carannante, Ilaria
D’Addio, Giovanni
Cesarelli, Mario
Balbi, Pietro
author_sort Andreozzi, Emilio
collection PubMed
description Computational models of ion channels represent the building blocks of conductance-based, biologically inspired models of neurons and neural networks. Ion channels are still widely modelled by means of the formalism developed by the seminal work of Hodgkin and Huxley (HH), although the electrophysiological features of the channels are currently known to be better fitted by means of kinetic Markov-type models. The present study is aimed at showing why simplified Markov-type kinetic models are more suitable for ion channels modelling as compared to HH ones, and how a manual optimization process can be rationally carried out for both. Previously published experimental data of an illustrative ion channel (Na(V)1.5) are exploited to develop a step by step optimization of the two models in close comparison. A conflicting practical limitation is recognized for the HH model, which only supplies one parameter to model two distinct electrophysiological behaviours. In addition, a step by step procedure is provided to correctly optimize the kinetic Markov-type model. Simplified Markov-type kinetic models are currently the best option to closely approximate the known complexity of the macroscopic currents of ion channels. Their optimization can be achieved through a rationally guided procedure, and allows to obtain models with a computational burden that is comparable with HH models one.
format Online
Article
Text
id pubmed-6877610
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-68776102019-12-05 Phenomenological models of Na(V)1.5. A side by side, procedural, hands-on comparison between Hodgkin-Huxley and kinetic formalisms Andreozzi, Emilio Carannante, Ilaria D’Addio, Giovanni Cesarelli, Mario Balbi, Pietro Sci Rep Article Computational models of ion channels represent the building blocks of conductance-based, biologically inspired models of neurons and neural networks. Ion channels are still widely modelled by means of the formalism developed by the seminal work of Hodgkin and Huxley (HH), although the electrophysiological features of the channels are currently known to be better fitted by means of kinetic Markov-type models. The present study is aimed at showing why simplified Markov-type kinetic models are more suitable for ion channels modelling as compared to HH ones, and how a manual optimization process can be rationally carried out for both. Previously published experimental data of an illustrative ion channel (Na(V)1.5) are exploited to develop a step by step optimization of the two models in close comparison. A conflicting practical limitation is recognized for the HH model, which only supplies one parameter to model two distinct electrophysiological behaviours. In addition, a step by step procedure is provided to correctly optimize the kinetic Markov-type model. Simplified Markov-type kinetic models are currently the best option to closely approximate the known complexity of the macroscopic currents of ion channels. Their optimization can be achieved through a rationally guided procedure, and allows to obtain models with a computational burden that is comparable with HH models one. Nature Publishing Group UK 2019-11-25 /pmc/articles/PMC6877610/ /pubmed/31767896 http://dx.doi.org/10.1038/s41598-019-53662-9 Text en © The Author(s) 2019 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Article
Andreozzi, Emilio
Carannante, Ilaria
D’Addio, Giovanni
Cesarelli, Mario
Balbi, Pietro
Phenomenological models of Na(V)1.5. A side by side, procedural, hands-on comparison between Hodgkin-Huxley and kinetic formalisms
title Phenomenological models of Na(V)1.5. A side by side, procedural, hands-on comparison between Hodgkin-Huxley and kinetic formalisms
title_full Phenomenological models of Na(V)1.5. A side by side, procedural, hands-on comparison between Hodgkin-Huxley and kinetic formalisms
title_fullStr Phenomenological models of Na(V)1.5. A side by side, procedural, hands-on comparison between Hodgkin-Huxley and kinetic formalisms
title_full_unstemmed Phenomenological models of Na(V)1.5. A side by side, procedural, hands-on comparison between Hodgkin-Huxley and kinetic formalisms
title_short Phenomenological models of Na(V)1.5. A side by side, procedural, hands-on comparison between Hodgkin-Huxley and kinetic formalisms
title_sort phenomenological models of na(v)1.5. a side by side, procedural, hands-on comparison between hodgkin-huxley and kinetic formalisms
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6877610/
https://www.ncbi.nlm.nih.gov/pubmed/31767896
http://dx.doi.org/10.1038/s41598-019-53662-9
work_keys_str_mv AT andreozziemilio phenomenologicalmodelsofnav15asidebysideproceduralhandsoncomparisonbetweenhodgkinhuxleyandkineticformalisms
AT carannanteilaria phenomenologicalmodelsofnav15asidebysideproceduralhandsoncomparisonbetweenhodgkinhuxleyandkineticformalisms
AT daddiogiovanni phenomenologicalmodelsofnav15asidebysideproceduralhandsoncomparisonbetweenhodgkinhuxleyandkineticformalisms
AT cesarellimario phenomenologicalmodelsofnav15asidebysideproceduralhandsoncomparisonbetweenhodgkinhuxleyandkineticformalisms
AT balbipietro phenomenologicalmodelsofnav15asidebysideproceduralhandsoncomparisonbetweenhodgkinhuxleyandkineticformalisms