Cargando…
Isometric knee muscle strength measurement using a belt-stabilized hand-held dynamometer and an isokinetic dynamometer with and without trunk fixation: investigation of agreement of measurement values and factors influencing measurement
[Purpose] The purpose of this study was to examine the agreement between the values obtained by using a hand-held dynamometer with a belt (belt-HHD) and an isokinetic dynamometer (IKD) for the measurement of isometric knee flexion and extension muscle strength. We also studied the factors influencin...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Society of Physical Therapy Science
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6879403/ https://www.ncbi.nlm.nih.gov/pubmed/31871370 http://dx.doi.org/10.1589/jpts.31.878 |
_version_ | 1783473584114499584 |
---|---|
author | Katoh, Munenori Hiiragi, Yukinobu Hirano, Masahiro Gomi, Masahiro Tozawa, Ryosuke Sakai, Yoshihito Tanaka, Masaru |
author_facet | Katoh, Munenori Hiiragi, Yukinobu Hirano, Masahiro Gomi, Masahiro Tozawa, Ryosuke Sakai, Yoshihito Tanaka, Masaru |
author_sort | Katoh, Munenori |
collection | PubMed |
description | [Purpose] The purpose of this study was to examine the agreement between the values obtained by using a hand-held dynamometer with a belt (belt-HHD) and an isokinetic dynamometer (IKD) for the measurement of isometric knee flexion and extension muscle strength. We also studied the factors influencing the measurement. [Participants and Methods] Overall, 26 healthy young adults (16 males, 10 females) participated in the study; the mean age was 21 years. Knee flexion and extension muscle strength were measured by three methods: 1) belt-HHD, 2) conventional IKD with the participant sitting on an attached chair (conv-IKD), and 3) modified IKD with the participant sitting on the same mat table as HHD (mod-IKD). [Results] In the measurement of knee extension, mod-IKD and conv-IKD showed a fixed bias and a proportional bias, conv-IKD and belt-HHD showed a fixed bias, and belt-HHD and mod-IKD showed a fixed bias. In the measurement knee flexion, conv-IKD and mod-IKD showed a proportional bias, belt-HHD and conv-IDK showed a fixed bias, and mod-IKD and belt-HHD showed a fixed bias. In each combination, the measured values were larger in the latter due to errors. However, the types and values of errors differed when analysis was conducted based on gender. [Conclusion] In order to increase the agreement between the values, it is necessary to revise the fixing method of the trunk, and the fixing method of the belt and the sensor pad in belt-HHD. |
format | Online Article Text |
id | pubmed-6879403 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | The Society of Physical Therapy Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-68794032019-12-23 Isometric knee muscle strength measurement using a belt-stabilized hand-held dynamometer and an isokinetic dynamometer with and without trunk fixation: investigation of agreement of measurement values and factors influencing measurement Katoh, Munenori Hiiragi, Yukinobu Hirano, Masahiro Gomi, Masahiro Tozawa, Ryosuke Sakai, Yoshihito Tanaka, Masaru J Phys Ther Sci Original Article [Purpose] The purpose of this study was to examine the agreement between the values obtained by using a hand-held dynamometer with a belt (belt-HHD) and an isokinetic dynamometer (IKD) for the measurement of isometric knee flexion and extension muscle strength. We also studied the factors influencing the measurement. [Participants and Methods] Overall, 26 healthy young adults (16 males, 10 females) participated in the study; the mean age was 21 years. Knee flexion and extension muscle strength were measured by three methods: 1) belt-HHD, 2) conventional IKD with the participant sitting on an attached chair (conv-IKD), and 3) modified IKD with the participant sitting on the same mat table as HHD (mod-IKD). [Results] In the measurement of knee extension, mod-IKD and conv-IKD showed a fixed bias and a proportional bias, conv-IKD and belt-HHD showed a fixed bias, and belt-HHD and mod-IKD showed a fixed bias. In the measurement knee flexion, conv-IKD and mod-IKD showed a proportional bias, belt-HHD and conv-IDK showed a fixed bias, and mod-IKD and belt-HHD showed a fixed bias. In each combination, the measured values were larger in the latter due to errors. However, the types and values of errors differed when analysis was conducted based on gender. [Conclusion] In order to increase the agreement between the values, it is necessary to revise the fixing method of the trunk, and the fixing method of the belt and the sensor pad in belt-HHD. The Society of Physical Therapy Science 2019-11-26 2019-11 /pmc/articles/PMC6879403/ /pubmed/31871370 http://dx.doi.org/10.1589/jpts.31.878 Text en 2019©by the Society of Physical Therapy Science. Published by IPEC Inc. This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivatives (by-nc-nd) License. (CC-BY-NC-ND 4.0: https://creativecommons.org/licenses/by-nc-nd/4.0/) |
spellingShingle | Original Article Katoh, Munenori Hiiragi, Yukinobu Hirano, Masahiro Gomi, Masahiro Tozawa, Ryosuke Sakai, Yoshihito Tanaka, Masaru Isometric knee muscle strength measurement using a belt-stabilized hand-held dynamometer and an isokinetic dynamometer with and without trunk fixation: investigation of agreement of measurement values and factors influencing measurement |
title | Isometric knee muscle strength measurement using a belt-stabilized hand-held
dynamometer and an isokinetic dynamometer with and without trunk fixation: investigation
of agreement of measurement values and factors influencing measurement |
title_full | Isometric knee muscle strength measurement using a belt-stabilized hand-held
dynamometer and an isokinetic dynamometer with and without trunk fixation: investigation
of agreement of measurement values and factors influencing measurement |
title_fullStr | Isometric knee muscle strength measurement using a belt-stabilized hand-held
dynamometer and an isokinetic dynamometer with and without trunk fixation: investigation
of agreement of measurement values and factors influencing measurement |
title_full_unstemmed | Isometric knee muscle strength measurement using a belt-stabilized hand-held
dynamometer and an isokinetic dynamometer with and without trunk fixation: investigation
of agreement of measurement values and factors influencing measurement |
title_short | Isometric knee muscle strength measurement using a belt-stabilized hand-held
dynamometer and an isokinetic dynamometer with and without trunk fixation: investigation
of agreement of measurement values and factors influencing measurement |
title_sort | isometric knee muscle strength measurement using a belt-stabilized hand-held
dynamometer and an isokinetic dynamometer with and without trunk fixation: investigation
of agreement of measurement values and factors influencing measurement |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6879403/ https://www.ncbi.nlm.nih.gov/pubmed/31871370 http://dx.doi.org/10.1589/jpts.31.878 |
work_keys_str_mv | AT katohmunenori isometrickneemusclestrengthmeasurementusingabeltstabilizedhandhelddynamometerandanisokineticdynamometerwithandwithouttrunkfixationinvestigationofagreementofmeasurementvaluesandfactorsinfluencingmeasurement AT hiiragiyukinobu isometrickneemusclestrengthmeasurementusingabeltstabilizedhandhelddynamometerandanisokineticdynamometerwithandwithouttrunkfixationinvestigationofagreementofmeasurementvaluesandfactorsinfluencingmeasurement AT hiranomasahiro isometrickneemusclestrengthmeasurementusingabeltstabilizedhandhelddynamometerandanisokineticdynamometerwithandwithouttrunkfixationinvestigationofagreementofmeasurementvaluesandfactorsinfluencingmeasurement AT gomimasahiro isometrickneemusclestrengthmeasurementusingabeltstabilizedhandhelddynamometerandanisokineticdynamometerwithandwithouttrunkfixationinvestigationofagreementofmeasurementvaluesandfactorsinfluencingmeasurement AT tozawaryosuke isometrickneemusclestrengthmeasurementusingabeltstabilizedhandhelddynamometerandanisokineticdynamometerwithandwithouttrunkfixationinvestigationofagreementofmeasurementvaluesandfactorsinfluencingmeasurement AT sakaiyoshihito isometrickneemusclestrengthmeasurementusingabeltstabilizedhandhelddynamometerandanisokineticdynamometerwithandwithouttrunkfixationinvestigationofagreementofmeasurementvaluesandfactorsinfluencingmeasurement AT tanakamasaru isometrickneemusclestrengthmeasurementusingabeltstabilizedhandhelddynamometerandanisokineticdynamometerwithandwithouttrunkfixationinvestigationofagreementofmeasurementvaluesandfactorsinfluencingmeasurement |