Cargando…

Isometric knee muscle strength measurement using a belt-stabilized hand-held dynamometer and an isokinetic dynamometer with and without trunk fixation: investigation of agreement of measurement values and factors influencing measurement

[Purpose] The purpose of this study was to examine the agreement between the values obtained by using a hand-held dynamometer with a belt (belt-HHD) and an isokinetic dynamometer (IKD) for the measurement of isometric knee flexion and extension muscle strength. We also studied the factors influencin...

Descripción completa

Detalles Bibliográficos
Autores principales: Katoh, Munenori, Hiiragi, Yukinobu, Hirano, Masahiro, Gomi, Masahiro, Tozawa, Ryosuke, Sakai, Yoshihito, Tanaka, Masaru
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Society of Physical Therapy Science 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6879403/
https://www.ncbi.nlm.nih.gov/pubmed/31871370
http://dx.doi.org/10.1589/jpts.31.878
_version_ 1783473584114499584
author Katoh, Munenori
Hiiragi, Yukinobu
Hirano, Masahiro
Gomi, Masahiro
Tozawa, Ryosuke
Sakai, Yoshihito
Tanaka, Masaru
author_facet Katoh, Munenori
Hiiragi, Yukinobu
Hirano, Masahiro
Gomi, Masahiro
Tozawa, Ryosuke
Sakai, Yoshihito
Tanaka, Masaru
author_sort Katoh, Munenori
collection PubMed
description [Purpose] The purpose of this study was to examine the agreement between the values obtained by using a hand-held dynamometer with a belt (belt-HHD) and an isokinetic dynamometer (IKD) for the measurement of isometric knee flexion and extension muscle strength. We also studied the factors influencing the measurement. [Participants and Methods] Overall, 26 healthy young adults (16 males, 10 females) participated in the study; the mean age was 21 years. Knee flexion and extension muscle strength were measured by three methods: 1) belt-HHD, 2) conventional IKD with the participant sitting on an attached chair (conv-IKD), and 3) modified IKD with the participant sitting on the same mat table as HHD (mod-IKD). [Results] In the measurement of knee extension, mod-IKD and conv-IKD showed a fixed bias and a proportional bias, conv-IKD and belt-HHD showed a fixed bias, and belt-HHD and mod-IKD showed a fixed bias. In the measurement knee flexion, conv-IKD and mod-IKD showed a proportional bias, belt-HHD and conv-IDK showed a fixed bias, and mod-IKD and belt-HHD showed a fixed bias. In each combination, the measured values were larger in the latter due to errors. However, the types and values of errors differed when analysis was conducted based on gender. [Conclusion] In order to increase the agreement between the values, it is necessary to revise the fixing method of the trunk, and the fixing method of the belt and the sensor pad in belt-HHD.
format Online
Article
Text
id pubmed-6879403
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher The Society of Physical Therapy Science
record_format MEDLINE/PubMed
spelling pubmed-68794032019-12-23 Isometric knee muscle strength measurement using a belt-stabilized hand-held dynamometer and an isokinetic dynamometer with and without trunk fixation: investigation of agreement of measurement values and factors influencing measurement Katoh, Munenori Hiiragi, Yukinobu Hirano, Masahiro Gomi, Masahiro Tozawa, Ryosuke Sakai, Yoshihito Tanaka, Masaru J Phys Ther Sci Original Article [Purpose] The purpose of this study was to examine the agreement between the values obtained by using a hand-held dynamometer with a belt (belt-HHD) and an isokinetic dynamometer (IKD) for the measurement of isometric knee flexion and extension muscle strength. We also studied the factors influencing the measurement. [Participants and Methods] Overall, 26 healthy young adults (16 males, 10 females) participated in the study; the mean age was 21 years. Knee flexion and extension muscle strength were measured by three methods: 1) belt-HHD, 2) conventional IKD with the participant sitting on an attached chair (conv-IKD), and 3) modified IKD with the participant sitting on the same mat table as HHD (mod-IKD). [Results] In the measurement of knee extension, mod-IKD and conv-IKD showed a fixed bias and a proportional bias, conv-IKD and belt-HHD showed a fixed bias, and belt-HHD and mod-IKD showed a fixed bias. In the measurement knee flexion, conv-IKD and mod-IKD showed a proportional bias, belt-HHD and conv-IDK showed a fixed bias, and mod-IKD and belt-HHD showed a fixed bias. In each combination, the measured values were larger in the latter due to errors. However, the types and values of errors differed when analysis was conducted based on gender. [Conclusion] In order to increase the agreement between the values, it is necessary to revise the fixing method of the trunk, and the fixing method of the belt and the sensor pad in belt-HHD. The Society of Physical Therapy Science 2019-11-26 2019-11 /pmc/articles/PMC6879403/ /pubmed/31871370 http://dx.doi.org/10.1589/jpts.31.878 Text en 2019©by the Society of Physical Therapy Science. Published by IPEC Inc. This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivatives (by-nc-nd) License. (CC-BY-NC-ND 4.0: https://creativecommons.org/licenses/by-nc-nd/4.0/)
spellingShingle Original Article
Katoh, Munenori
Hiiragi, Yukinobu
Hirano, Masahiro
Gomi, Masahiro
Tozawa, Ryosuke
Sakai, Yoshihito
Tanaka, Masaru
Isometric knee muscle strength measurement using a belt-stabilized hand-held dynamometer and an isokinetic dynamometer with and without trunk fixation: investigation of agreement of measurement values and factors influencing measurement
title Isometric knee muscle strength measurement using a belt-stabilized hand-held dynamometer and an isokinetic dynamometer with and without trunk fixation: investigation of agreement of measurement values and factors influencing measurement
title_full Isometric knee muscle strength measurement using a belt-stabilized hand-held dynamometer and an isokinetic dynamometer with and without trunk fixation: investigation of agreement of measurement values and factors influencing measurement
title_fullStr Isometric knee muscle strength measurement using a belt-stabilized hand-held dynamometer and an isokinetic dynamometer with and without trunk fixation: investigation of agreement of measurement values and factors influencing measurement
title_full_unstemmed Isometric knee muscle strength measurement using a belt-stabilized hand-held dynamometer and an isokinetic dynamometer with and without trunk fixation: investigation of agreement of measurement values and factors influencing measurement
title_short Isometric knee muscle strength measurement using a belt-stabilized hand-held dynamometer and an isokinetic dynamometer with and without trunk fixation: investigation of agreement of measurement values and factors influencing measurement
title_sort isometric knee muscle strength measurement using a belt-stabilized hand-held dynamometer and an isokinetic dynamometer with and without trunk fixation: investigation of agreement of measurement values and factors influencing measurement
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6879403/
https://www.ncbi.nlm.nih.gov/pubmed/31871370
http://dx.doi.org/10.1589/jpts.31.878
work_keys_str_mv AT katohmunenori isometrickneemusclestrengthmeasurementusingabeltstabilizedhandhelddynamometerandanisokineticdynamometerwithandwithouttrunkfixationinvestigationofagreementofmeasurementvaluesandfactorsinfluencingmeasurement
AT hiiragiyukinobu isometrickneemusclestrengthmeasurementusingabeltstabilizedhandhelddynamometerandanisokineticdynamometerwithandwithouttrunkfixationinvestigationofagreementofmeasurementvaluesandfactorsinfluencingmeasurement
AT hiranomasahiro isometrickneemusclestrengthmeasurementusingabeltstabilizedhandhelddynamometerandanisokineticdynamometerwithandwithouttrunkfixationinvestigationofagreementofmeasurementvaluesandfactorsinfluencingmeasurement
AT gomimasahiro isometrickneemusclestrengthmeasurementusingabeltstabilizedhandhelddynamometerandanisokineticdynamometerwithandwithouttrunkfixationinvestigationofagreementofmeasurementvaluesandfactorsinfluencingmeasurement
AT tozawaryosuke isometrickneemusclestrengthmeasurementusingabeltstabilizedhandhelddynamometerandanisokineticdynamometerwithandwithouttrunkfixationinvestigationofagreementofmeasurementvaluesandfactorsinfluencingmeasurement
AT sakaiyoshihito isometrickneemusclestrengthmeasurementusingabeltstabilizedhandhelddynamometerandanisokineticdynamometerwithandwithouttrunkfixationinvestigationofagreementofmeasurementvaluesandfactorsinfluencingmeasurement
AT tanakamasaru isometrickneemusclestrengthmeasurementusingabeltstabilizedhandhelddynamometerandanisokineticdynamometerwithandwithouttrunkfixationinvestigationofagreementofmeasurementvaluesandfactorsinfluencingmeasurement