Cargando…

Mechanical power at a glance: a simple surrogate for volume-controlled ventilation

BACKGROUND: Mechanical power is a summary variable including all the components which can possibly cause VILI (pressures, volume, flow, respiratory rate). Since the complexity of its mathematical computation is one of the major factors that delay its clinical use, we propose here a simple and easy t...

Descripción completa

Detalles Bibliográficos
Autores principales: Giosa, Lorenzo, Busana, Mattia, Pasticci, Iacopo, Bonifazi, Matteo, Macrì, Matteo Maria, Romitti, Federica, Vassalli, Francesco, Chiumello, Davide, Quintel, Michael, Marini, J. J., Gattinoni, Luciano
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6879677/
https://www.ncbi.nlm.nih.gov/pubmed/31773328
http://dx.doi.org/10.1186/s40635-019-0276-8
_version_ 1783473652151353344
author Giosa, Lorenzo
Busana, Mattia
Pasticci, Iacopo
Bonifazi, Matteo
Macrì, Matteo Maria
Romitti, Federica
Vassalli, Francesco
Chiumello, Davide
Quintel, Michael
Marini, J. J.
Gattinoni, Luciano
author_facet Giosa, Lorenzo
Busana, Mattia
Pasticci, Iacopo
Bonifazi, Matteo
Macrì, Matteo Maria
Romitti, Federica
Vassalli, Francesco
Chiumello, Davide
Quintel, Michael
Marini, J. J.
Gattinoni, Luciano
author_sort Giosa, Lorenzo
collection PubMed
description BACKGROUND: Mechanical power is a summary variable including all the components which can possibly cause VILI (pressures, volume, flow, respiratory rate). Since the complexity of its mathematical computation is one of the major factors that delay its clinical use, we propose here a simple and easy to remember equation to estimate mechanical power under volume-controlled ventilation: [Formula: see text] where the mechanical power is expressed in Joules/minute, the minute ventilation (VE) in liters/minute, the inspiratory flow (F) in liters/minute, and peak pressure and positive end-expiratory pressure (PEEP) in centimeter of water. All the components of this equation are continuously displayed by any ventilator under volume-controlled ventilation without the need for clinician intervention. To test the accuracy of this new equation, we compared it with the reference formula of mechanical power that we proposed for volume-controlled ventilation in the past. The comparisons were made in a cohort of mechanically ventilated pigs (485 observations) and in a cohort of ICU patients (265 observations). RESULTS: Both in pigs and in ICU patients, the correlation between our equation and the reference one was close to the identity. Indeed, the R(2) ranged from 0.97 to 0.99 and the Bland-Altman showed small biases (ranging from + 0.35 to − 0.53 J/min) and proportional errors (ranging from + 0.02 to − 0.05). CONCLUSIONS: Our new equation of mechanical power for volume-controlled ventilation represents a simple and accurate alternative to the more complex ones available to date. This equation does not need any clinical intervention on the ventilator (such as an inspiratory hold) and could be easily implemented in the software of any ventilator in volume-controlled mode. This would allow the clinician to have an estimation of mechanical power at a simple glance and thus increase the clinical consciousness of this variable which is still far from being used at the bedside. Our equation carries the same limitations of all other formulas of mechanical power, the most important of which, as far as it concerns VILI prevention, are the lack of normalization and its application to the whole respiratory system (including the chest wall) and not only to the lung parenchyma.
format Online
Article
Text
id pubmed-6879677
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-68796772019-12-10 Mechanical power at a glance: a simple surrogate for volume-controlled ventilation Giosa, Lorenzo Busana, Mattia Pasticci, Iacopo Bonifazi, Matteo Macrì, Matteo Maria Romitti, Federica Vassalli, Francesco Chiumello, Davide Quintel, Michael Marini, J. J. Gattinoni, Luciano Intensive Care Med Exp Research BACKGROUND: Mechanical power is a summary variable including all the components which can possibly cause VILI (pressures, volume, flow, respiratory rate). Since the complexity of its mathematical computation is one of the major factors that delay its clinical use, we propose here a simple and easy to remember equation to estimate mechanical power under volume-controlled ventilation: [Formula: see text] where the mechanical power is expressed in Joules/minute, the minute ventilation (VE) in liters/minute, the inspiratory flow (F) in liters/minute, and peak pressure and positive end-expiratory pressure (PEEP) in centimeter of water. All the components of this equation are continuously displayed by any ventilator under volume-controlled ventilation without the need for clinician intervention. To test the accuracy of this new equation, we compared it with the reference formula of mechanical power that we proposed for volume-controlled ventilation in the past. The comparisons were made in a cohort of mechanically ventilated pigs (485 observations) and in a cohort of ICU patients (265 observations). RESULTS: Both in pigs and in ICU patients, the correlation between our equation and the reference one was close to the identity. Indeed, the R(2) ranged from 0.97 to 0.99 and the Bland-Altman showed small biases (ranging from + 0.35 to − 0.53 J/min) and proportional errors (ranging from + 0.02 to − 0.05). CONCLUSIONS: Our new equation of mechanical power for volume-controlled ventilation represents a simple and accurate alternative to the more complex ones available to date. This equation does not need any clinical intervention on the ventilator (such as an inspiratory hold) and could be easily implemented in the software of any ventilator in volume-controlled mode. This would allow the clinician to have an estimation of mechanical power at a simple glance and thus increase the clinical consciousness of this variable which is still far from being used at the bedside. Our equation carries the same limitations of all other formulas of mechanical power, the most important of which, as far as it concerns VILI prevention, are the lack of normalization and its application to the whole respiratory system (including the chest wall) and not only to the lung parenchyma. Springer International Publishing 2019-11-27 /pmc/articles/PMC6879677/ /pubmed/31773328 http://dx.doi.org/10.1186/s40635-019-0276-8 Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Research
Giosa, Lorenzo
Busana, Mattia
Pasticci, Iacopo
Bonifazi, Matteo
Macrì, Matteo Maria
Romitti, Federica
Vassalli, Francesco
Chiumello, Davide
Quintel, Michael
Marini, J. J.
Gattinoni, Luciano
Mechanical power at a glance: a simple surrogate for volume-controlled ventilation
title Mechanical power at a glance: a simple surrogate for volume-controlled ventilation
title_full Mechanical power at a glance: a simple surrogate for volume-controlled ventilation
title_fullStr Mechanical power at a glance: a simple surrogate for volume-controlled ventilation
title_full_unstemmed Mechanical power at a glance: a simple surrogate for volume-controlled ventilation
title_short Mechanical power at a glance: a simple surrogate for volume-controlled ventilation
title_sort mechanical power at a glance: a simple surrogate for volume-controlled ventilation
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6879677/
https://www.ncbi.nlm.nih.gov/pubmed/31773328
http://dx.doi.org/10.1186/s40635-019-0276-8
work_keys_str_mv AT giosalorenzo mechanicalpowerataglanceasimplesurrogateforvolumecontrolledventilation
AT busanamattia mechanicalpowerataglanceasimplesurrogateforvolumecontrolledventilation
AT pasticciiacopo mechanicalpowerataglanceasimplesurrogateforvolumecontrolledventilation
AT bonifazimatteo mechanicalpowerataglanceasimplesurrogateforvolumecontrolledventilation
AT macrimatteomaria mechanicalpowerataglanceasimplesurrogateforvolumecontrolledventilation
AT romittifederica mechanicalpowerataglanceasimplesurrogateforvolumecontrolledventilation
AT vassallifrancesco mechanicalpowerataglanceasimplesurrogateforvolumecontrolledventilation
AT chiumellodavide mechanicalpowerataglanceasimplesurrogateforvolumecontrolledventilation
AT quintelmichael mechanicalpowerataglanceasimplesurrogateforvolumecontrolledventilation
AT marinijj mechanicalpowerataglanceasimplesurrogateforvolumecontrolledventilation
AT gattinoniluciano mechanicalpowerataglanceasimplesurrogateforvolumecontrolledventilation