Cargando…
Reliability and validity of miniscrews as references in cone-beam computed tomography and intraoral scanner digital models: study on goat heads
BACKGROUND: Miniscrews have been used to superimpose three-dimensional (3D) craniofacial images as well as explore stable structures in jaws. Our purpose was to evaluate the reliability and validity of linear and angular measurements made with miniscrews on a 3D cone-beam computed tomography (CBCT)...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6880591/ https://www.ncbi.nlm.nih.gov/pubmed/31771579 http://dx.doi.org/10.1186/s12903-019-0952-9 |
_version_ | 1783473792507445248 |
---|---|
author | Jiang, Yiran Chen, Gui |
author_facet | Jiang, Yiran Chen, Gui |
author_sort | Jiang, Yiran |
collection | PubMed |
description | BACKGROUND: Miniscrews have been used to superimpose three-dimensional (3D) craniofacial images as well as explore stable structures in jaws. Our purpose was to evaluate the reliability and validity of linear and angular measurements made with miniscrews on a 3D cone-beam computed tomography (CBCT) at two voxel sizes and compared to models created by an intraoral scanner (IOS). METHODS: Altogether, 64 miniscrews were placed in 12 goat jaws. The jaws were scanned by CBCT machine at 0.12 mm and 0.3 mm voxels and by the IOS. Linear and angular measurements between miniscrews on CBCT at the two voxel settings and the IOS were compared with actual measurements and with each other. RESULTS: An intra-and inter-class correlation of 0.961–1.000 were obtained by each method. Linear measurements showed significant overestimations of 0.27 ± 0.24, 0.14 ± 0.22 and 0.15 ± 0.26 mm, and angular measurements showed non-significant differences of 0.11 ± 1.97°, 0.15 ± 2.79° and 0.41 ± 2.34° for the CBCT at 0.12-mm, 0.3-mm voxels and the IOS, respectively. Equal magnification of linear measurements was on homolateral and contralateral sides using CBCT, whereas significantly greater magnification on the homolateral side than on the opposite was observed using the IOS. There was no significant difference with angular measurements between digital CBCT models at two voxels and IOS. In addition, all angular measurements were comparable to actual measurement results. CONCLUSIONS: Miniscrews in CBCT and IOS are reliable and clinical valid when used as a reference measuring tooth movement. However, when miniscrews are involved in high precision measurement in CBCT or IOS image, systematic error should be taken into consideration. When comparing CBCT images, using the same voxel size is recommended for miniscrew related measurements to reduce error. |
format | Online Article Text |
id | pubmed-6880591 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-68805912019-11-29 Reliability and validity of miniscrews as references in cone-beam computed tomography and intraoral scanner digital models: study on goat heads Jiang, Yiran Chen, Gui BMC Oral Health Research Article BACKGROUND: Miniscrews have been used to superimpose three-dimensional (3D) craniofacial images as well as explore stable structures in jaws. Our purpose was to evaluate the reliability and validity of linear and angular measurements made with miniscrews on a 3D cone-beam computed tomography (CBCT) at two voxel sizes and compared to models created by an intraoral scanner (IOS). METHODS: Altogether, 64 miniscrews were placed in 12 goat jaws. The jaws were scanned by CBCT machine at 0.12 mm and 0.3 mm voxels and by the IOS. Linear and angular measurements between miniscrews on CBCT at the two voxel settings and the IOS were compared with actual measurements and with each other. RESULTS: An intra-and inter-class correlation of 0.961–1.000 were obtained by each method. Linear measurements showed significant overestimations of 0.27 ± 0.24, 0.14 ± 0.22 and 0.15 ± 0.26 mm, and angular measurements showed non-significant differences of 0.11 ± 1.97°, 0.15 ± 2.79° and 0.41 ± 2.34° for the CBCT at 0.12-mm, 0.3-mm voxels and the IOS, respectively. Equal magnification of linear measurements was on homolateral and contralateral sides using CBCT, whereas significantly greater magnification on the homolateral side than on the opposite was observed using the IOS. There was no significant difference with angular measurements between digital CBCT models at two voxels and IOS. In addition, all angular measurements were comparable to actual measurement results. CONCLUSIONS: Miniscrews in CBCT and IOS are reliable and clinical valid when used as a reference measuring tooth movement. However, when miniscrews are involved in high precision measurement in CBCT or IOS image, systematic error should be taken into consideration. When comparing CBCT images, using the same voxel size is recommended for miniscrew related measurements to reduce error. BioMed Central 2019-11-27 /pmc/articles/PMC6880591/ /pubmed/31771579 http://dx.doi.org/10.1186/s12903-019-0952-9 Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article Jiang, Yiran Chen, Gui Reliability and validity of miniscrews as references in cone-beam computed tomography and intraoral scanner digital models: study on goat heads |
title | Reliability and validity of miniscrews as references in cone-beam computed tomography and intraoral scanner digital models: study on goat heads |
title_full | Reliability and validity of miniscrews as references in cone-beam computed tomography and intraoral scanner digital models: study on goat heads |
title_fullStr | Reliability and validity of miniscrews as references in cone-beam computed tomography and intraoral scanner digital models: study on goat heads |
title_full_unstemmed | Reliability and validity of miniscrews as references in cone-beam computed tomography and intraoral scanner digital models: study on goat heads |
title_short | Reliability and validity of miniscrews as references in cone-beam computed tomography and intraoral scanner digital models: study on goat heads |
title_sort | reliability and validity of miniscrews as references in cone-beam computed tomography and intraoral scanner digital models: study on goat heads |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6880591/ https://www.ncbi.nlm.nih.gov/pubmed/31771579 http://dx.doi.org/10.1186/s12903-019-0952-9 |
work_keys_str_mv | AT jiangyiran reliabilityandvalidityofminiscrewsasreferencesinconebeamcomputedtomographyandintraoralscannerdigitalmodelsstudyongoatheads AT chengui reliabilityandvalidityofminiscrewsasreferencesinconebeamcomputedtomographyandintraoralscannerdigitalmodelsstudyongoatheads |