Significant artefactual noise in (90)Y TOF-PET imaging of low specific activity phantoms arises despite increased acquisition time

Volumes of usual PET phantoms are about four to sixfold that of a human liver. In order to avoid count rate saturation and handling of very high (90)Y activity, reported TOF-PET phantom studies are performed using specific activities lower than those observed in liver radioembolization. However, due...

Descripción completa

Detalles Bibliográficos
Autores principales: Hesse, Michel, Walrand, Stephan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6882976/
https://www.ncbi.nlm.nih.gov/pubmed/31781879
http://dx.doi.org/10.1186/s40658-019-0259-6
_version_ 1783474278950240256
author Hesse, Michel
Walrand, Stephan
author_facet Hesse, Michel
Walrand, Stephan
author_sort Hesse, Michel
collection PubMed
description Volumes of usual PET phantoms are about four to sixfold that of a human liver. In order to avoid count rate saturation and handling of very high (90)Y activity, reported TOF-PET phantom studies are performed using specific activities lower than those observed in liver radioembolization. However, due to the constant random coincidence rate induced by the natural crystal radioactivity, reduction of (90)Y specific activity in TOF-PET imaging cannot be counterbalanced by increasing the acquisition time. As a result, most (90)Y phantom studies reported images noisier than those obtained in whole-body (18)F-FDG, and thus advised to use dedicated noise control in TOF-PET imaging post (90)Y liver radioembolization. We performed acquisitions of the Jaszczak Deluxe phantom in which the hot rod insert was only partially filled with 2.6 GBq of (90)Y. Standard reconstruction parameters recommended by the manufacturer for whole-body (18)F-FDG PET were used. Low specific activity setups, although exactly compensated by increasing the acquisition time in order to get the same number of detected true coincidences per millilitre, were impacted by significant noise. On the other hand, specific activity and acquisition time setup similar to that used in post (90)Y liver radioembolization provided image quality very close to that of whole-body (18)F-FDG. This result clearly discards the use of low specific activity phantoms intended to TOF-PET reconstruction parameter optimization. Volume reduction of large phantoms can be achieved by vertically setting the phantoms or by adding Styrofoam inserts.
format Online
Article
Text
id pubmed-6882976
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-68829762019-12-12 Significant artefactual noise in (90)Y TOF-PET imaging of low specific activity phantoms arises despite increased acquisition time Hesse, Michel Walrand, Stephan EJNMMI Phys Artefact Report Volumes of usual PET phantoms are about four to sixfold that of a human liver. In order to avoid count rate saturation and handling of very high (90)Y activity, reported TOF-PET phantom studies are performed using specific activities lower than those observed in liver radioembolization. However, due to the constant random coincidence rate induced by the natural crystal radioactivity, reduction of (90)Y specific activity in TOF-PET imaging cannot be counterbalanced by increasing the acquisition time. As a result, most (90)Y phantom studies reported images noisier than those obtained in whole-body (18)F-FDG, and thus advised to use dedicated noise control in TOF-PET imaging post (90)Y liver radioembolization. We performed acquisitions of the Jaszczak Deluxe phantom in which the hot rod insert was only partially filled with 2.6 GBq of (90)Y. Standard reconstruction parameters recommended by the manufacturer for whole-body (18)F-FDG PET were used. Low specific activity setups, although exactly compensated by increasing the acquisition time in order to get the same number of detected true coincidences per millilitre, were impacted by significant noise. On the other hand, specific activity and acquisition time setup similar to that used in post (90)Y liver radioembolization provided image quality very close to that of whole-body (18)F-FDG. This result clearly discards the use of low specific activity phantoms intended to TOF-PET reconstruction parameter optimization. Volume reduction of large phantoms can be achieved by vertically setting the phantoms or by adding Styrofoam inserts. Springer International Publishing 2019-11-28 /pmc/articles/PMC6882976/ /pubmed/31781879 http://dx.doi.org/10.1186/s40658-019-0259-6 Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Artefact Report
Hesse, Michel
Walrand, Stephan
Significant artefactual noise in (90)Y TOF-PET imaging of low specific activity phantoms arises despite increased acquisition time
title Significant artefactual noise in (90)Y TOF-PET imaging of low specific activity phantoms arises despite increased acquisition time
title_full Significant artefactual noise in (90)Y TOF-PET imaging of low specific activity phantoms arises despite increased acquisition time
title_fullStr Significant artefactual noise in (90)Y TOF-PET imaging of low specific activity phantoms arises despite increased acquisition time
title_full_unstemmed Significant artefactual noise in (90)Y TOF-PET imaging of low specific activity phantoms arises despite increased acquisition time
title_short Significant artefactual noise in (90)Y TOF-PET imaging of low specific activity phantoms arises despite increased acquisition time
title_sort significant artefactual noise in (90)y tof-pet imaging of low specific activity phantoms arises despite increased acquisition time
topic Artefact Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6882976/
https://www.ncbi.nlm.nih.gov/pubmed/31781879
http://dx.doi.org/10.1186/s40658-019-0259-6
work_keys_str_mv AT hessemichel significantartefactualnoisein90ytofpetimagingoflowspecificactivityphantomsarisesdespiteincreasedacquisitiontime
AT walrandstephan significantartefactualnoisein90ytofpetimagingoflowspecificactivityphantomsarisesdespiteincreasedacquisitiontime