Cargando…

Stainless steel wire in a figure-of-eight for repair of distal femoral physeal fractures in ten cats: a case report

Ten cats were treated for distal femoral Salter-Harris fractures types I and II using a stainless steel wire in a figure-of-eight configuration. Healing was uneventful in 8 of the cats. Early fixation failure occurred in one cat, which required revisional surgery. In one cat, lameness recurred after...

Descripción completa

Detalles Bibliográficos
Autores principales: Spångberg, Camilla, Spångberg, Inga-Britt, Bergström, Annika
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society of Veterinary Science 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6883204/
https://www.ncbi.nlm.nih.gov/pubmed/31775198
http://dx.doi.org/10.4142/jvs.2019.20.e71
_version_ 1783474316727287808
author Spångberg, Camilla
Spångberg, Inga-Britt
Bergström, Annika
author_facet Spångberg, Camilla
Spångberg, Inga-Britt
Bergström, Annika
author_sort Spångberg, Camilla
collection PubMed
description Ten cats were treated for distal femoral Salter-Harris fractures types I and II using a stainless steel wire in a figure-of-eight configuration. Healing was uneventful in 8 of the cats. Early fixation failure occurred in one cat, which required revisional surgery. In one cat, lameness recurred after fracture healing, which was related to breakage of the wire. The lameness was resolved after removing the wire. At the long-term follow-up, 1 out of 6 cats was lame. This report indicates that the figure-of-eight stainless steel wire technique is an alternative method for the repair of distal femoral Salter-Harris fractures types I and II in cats.
format Online
Article
Text
id pubmed-6883204
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher The Korean Society of Veterinary Science
record_format MEDLINE/PubMed
spelling pubmed-68832042019-12-08 Stainless steel wire in a figure-of-eight for repair of distal femoral physeal fractures in ten cats: a case report Spångberg, Camilla Spångberg, Inga-Britt Bergström, Annika J Vet Sci Case Report Ten cats were treated for distal femoral Salter-Harris fractures types I and II using a stainless steel wire in a figure-of-eight configuration. Healing was uneventful in 8 of the cats. Early fixation failure occurred in one cat, which required revisional surgery. In one cat, lameness recurred after fracture healing, which was related to breakage of the wire. The lameness was resolved after removing the wire. At the long-term follow-up, 1 out of 6 cats was lame. This report indicates that the figure-of-eight stainless steel wire technique is an alternative method for the repair of distal femoral Salter-Harris fractures types I and II in cats. The Korean Society of Veterinary Science 2019-11 2019-11-05 /pmc/articles/PMC6883204/ /pubmed/31775198 http://dx.doi.org/10.4142/jvs.2019.20.e71 Text en © 2019 The Korean Society of Veterinary Science https://creativecommons.org/licenses/by-nc/4.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Spångberg, Camilla
Spångberg, Inga-Britt
Bergström, Annika
Stainless steel wire in a figure-of-eight for repair of distal femoral physeal fractures in ten cats: a case report
title Stainless steel wire in a figure-of-eight for repair of distal femoral physeal fractures in ten cats: a case report
title_full Stainless steel wire in a figure-of-eight for repair of distal femoral physeal fractures in ten cats: a case report
title_fullStr Stainless steel wire in a figure-of-eight for repair of distal femoral physeal fractures in ten cats: a case report
title_full_unstemmed Stainless steel wire in a figure-of-eight for repair of distal femoral physeal fractures in ten cats: a case report
title_short Stainless steel wire in a figure-of-eight for repair of distal femoral physeal fractures in ten cats: a case report
title_sort stainless steel wire in a figure-of-eight for repair of distal femoral physeal fractures in ten cats: a case report
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6883204/
https://www.ncbi.nlm.nih.gov/pubmed/31775198
http://dx.doi.org/10.4142/jvs.2019.20.e71
work_keys_str_mv AT spangbergcamilla stainlesssteelwireinafigureofeightforrepairofdistalfemoralphysealfracturesintencatsacasereport
AT spangbergingabritt stainlesssteelwireinafigureofeightforrepairofdistalfemoralphysealfracturesintencatsacasereport
AT bergstromannika stainlesssteelwireinafigureofeightforrepairofdistalfemoralphysealfracturesintencatsacasereport