Stainless steel wire in a figure-of-eight for repair of distal femoral physeal fractures in ten cats: a case report
Ten cats were treated for distal femoral Salter-Harris fractures types I and II using a stainless steel wire in a figure-of-eight configuration. Healing was uneventful in 8 of the cats. Early fixation failure occurred in one cat, which required revisional surgery. In one cat, lameness recurred after...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society of Veterinary Science
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6883204/ https://www.ncbi.nlm.nih.gov/pubmed/31775198 http://dx.doi.org/10.4142/jvs.2019.20.e71 |
_version_ | 1783474316727287808 |
---|---|
author | Spångberg, Camilla Spångberg, Inga-Britt Bergström, Annika |
author_facet | Spångberg, Camilla Spångberg, Inga-Britt Bergström, Annika |
author_sort | Spångberg, Camilla |
collection | PubMed |
description | Ten cats were treated for distal femoral Salter-Harris fractures types I and II using a stainless steel wire in a figure-of-eight configuration. Healing was uneventful in 8 of the cats. Early fixation failure occurred in one cat, which required revisional surgery. In one cat, lameness recurred after fracture healing, which was related to breakage of the wire. The lameness was resolved after removing the wire. At the long-term follow-up, 1 out of 6 cats was lame. This report indicates that the figure-of-eight stainless steel wire technique is an alternative method for the repair of distal femoral Salter-Harris fractures types I and II in cats. |
format | Online Article Text |
id | pubmed-6883204 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | The Korean Society of Veterinary Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-68832042019-12-08 Stainless steel wire in a figure-of-eight for repair of distal femoral physeal fractures in ten cats: a case report Spångberg, Camilla Spångberg, Inga-Britt Bergström, Annika J Vet Sci Case Report Ten cats were treated for distal femoral Salter-Harris fractures types I and II using a stainless steel wire in a figure-of-eight configuration. Healing was uneventful in 8 of the cats. Early fixation failure occurred in one cat, which required revisional surgery. In one cat, lameness recurred after fracture healing, which was related to breakage of the wire. The lameness was resolved after removing the wire. At the long-term follow-up, 1 out of 6 cats was lame. This report indicates that the figure-of-eight stainless steel wire technique is an alternative method for the repair of distal femoral Salter-Harris fractures types I and II in cats. The Korean Society of Veterinary Science 2019-11 2019-11-05 /pmc/articles/PMC6883204/ /pubmed/31775198 http://dx.doi.org/10.4142/jvs.2019.20.e71 Text en © 2019 The Korean Society of Veterinary Science https://creativecommons.org/licenses/by-nc/4.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Report Spångberg, Camilla Spångberg, Inga-Britt Bergström, Annika Stainless steel wire in a figure-of-eight for repair of distal femoral physeal fractures in ten cats: a case report |
title | Stainless steel wire in a figure-of-eight for repair of distal femoral physeal fractures in ten cats: a case report |
title_full | Stainless steel wire in a figure-of-eight for repair of distal femoral physeal fractures in ten cats: a case report |
title_fullStr | Stainless steel wire in a figure-of-eight for repair of distal femoral physeal fractures in ten cats: a case report |
title_full_unstemmed | Stainless steel wire in a figure-of-eight for repair of distal femoral physeal fractures in ten cats: a case report |
title_short | Stainless steel wire in a figure-of-eight for repair of distal femoral physeal fractures in ten cats: a case report |
title_sort | stainless steel wire in a figure-of-eight for repair of distal femoral physeal fractures in ten cats: a case report |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6883204/ https://www.ncbi.nlm.nih.gov/pubmed/31775198 http://dx.doi.org/10.4142/jvs.2019.20.e71 |
work_keys_str_mv | AT spangbergcamilla stainlesssteelwireinafigureofeightforrepairofdistalfemoralphysealfracturesintencatsacasereport AT spangbergingabritt stainlesssteelwireinafigureofeightforrepairofdistalfemoralphysealfracturesintencatsacasereport AT bergstromannika stainlesssteelwireinafigureofeightforrepairofdistalfemoralphysealfracturesintencatsacasereport |