Analysing tropical elasmobranch blood samples in the field: blood stability during storage and validation of the HemoCue® haemoglobin analyser

Blood samples collected from wild-caught fishes can provide important information regarding the effects of capture (and thus post-release survival) as well as other stressors. Unfortunately, blood samples often cannot be analysed immediately upon sampling, and blood parameters (e.g. blood oxygen lev...

Descripción completa

Detalles Bibliográficos
Autores principales: Schwieterman, Gail D, Bouyoucos, Ian A, Potgieter, Kristy, Simpfendorfer, Colin A, Brill, Richard W, Rummer, Jodie L
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6883209/
https://www.ncbi.nlm.nih.gov/pubmed/31803471
http://dx.doi.org/10.1093/conphys/coz081
_version_ 1783474317688832000
author Schwieterman, Gail D
Bouyoucos, Ian A
Potgieter, Kristy
Simpfendorfer, Colin A
Brill, Richard W
Rummer, Jodie L
author_facet Schwieterman, Gail D
Bouyoucos, Ian A
Potgieter, Kristy
Simpfendorfer, Colin A
Brill, Richard W
Rummer, Jodie L
author_sort Schwieterman, Gail D
collection PubMed
description Blood samples collected from wild-caught fishes can provide important information regarding the effects of capture (and thus post-release survival) as well as other stressors. Unfortunately, blood samples often cannot be analysed immediately upon sampling, and blood parameters (e.g. blood oxygen levels and acid–base parameters) are known to change with storage duration due to the metabolic activity of the red blood cells. We obtained blood samples from both untreated and stressed individuals of both blacktip reef shark (Carcharhinus melanopterus) and sicklefin lemon shark (Negaprion acutidens) to determine the effects of storage duration on blood pH, haematocrit and haemoglobin concentration ([Hb]). We found no significant effects after storage on ice for up to 180 minutes. Moreover, to validate the usability of a HemoCue haemoglobin analyser (a point-of-care device), we compared data from this device to [Hb] determined using the cyanomethaemoglobin method with blood samples from 10 individuals from each of the aforementioned species as well as epaulette shark (Hemiscyllium ocellatum). Values from the HemoCue consistently overestimated [Hb], and we therefore developed the necessary correction equations. The correction equations were not statistically different among the three elasmobranch species within the biologically relevant range but did differ from published corrections developed using blood from temperate teleost fishes. Although the HemoCue is useful in field situations, development of species-specific calibration equations may be necessary to ensure the reliability of inter-species comparisons of blood [Hb]. Together, these data should increase confidence in haematological stress indicators in elasmobranch fishes, measurements of which are critical for understanding the impact of anthropogenic stressors on these ecologically important species.
format Online
Article
Text
id pubmed-6883209
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-68832092019-12-04 Analysing tropical elasmobranch blood samples in the field: blood stability during storage and validation of the HemoCue® haemoglobin analyser Schwieterman, Gail D Bouyoucos, Ian A Potgieter, Kristy Simpfendorfer, Colin A Brill, Richard W Rummer, Jodie L Conserv Physiol Toolbox Blood samples collected from wild-caught fishes can provide important information regarding the effects of capture (and thus post-release survival) as well as other stressors. Unfortunately, blood samples often cannot be analysed immediately upon sampling, and blood parameters (e.g. blood oxygen levels and acid–base parameters) are known to change with storage duration due to the metabolic activity of the red blood cells. We obtained blood samples from both untreated and stressed individuals of both blacktip reef shark (Carcharhinus melanopterus) and sicklefin lemon shark (Negaprion acutidens) to determine the effects of storage duration on blood pH, haematocrit and haemoglobin concentration ([Hb]). We found no significant effects after storage on ice for up to 180 minutes. Moreover, to validate the usability of a HemoCue haemoglobin analyser (a point-of-care device), we compared data from this device to [Hb] determined using the cyanomethaemoglobin method with blood samples from 10 individuals from each of the aforementioned species as well as epaulette shark (Hemiscyllium ocellatum). Values from the HemoCue consistently overestimated [Hb], and we therefore developed the necessary correction equations. The correction equations were not statistically different among the three elasmobranch species within the biologically relevant range but did differ from published corrections developed using blood from temperate teleost fishes. Although the HemoCue is useful in field situations, development of species-specific calibration equations may be necessary to ensure the reliability of inter-species comparisons of blood [Hb]. Together, these data should increase confidence in haematological stress indicators in elasmobranch fishes, measurements of which are critical for understanding the impact of anthropogenic stressors on these ecologically important species. Oxford University Press 2019-11-29 /pmc/articles/PMC6883209/ /pubmed/31803471 http://dx.doi.org/10.1093/conphys/coz081 Text en © The Author(s) 2019. Published by Oxford University Press and the Society for Experimental Biology. http://creativecommons.org/licenses/by/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Toolbox
Schwieterman, Gail D
Bouyoucos, Ian A
Potgieter, Kristy
Simpfendorfer, Colin A
Brill, Richard W
Rummer, Jodie L
Analysing tropical elasmobranch blood samples in the field: blood stability during storage and validation of the HemoCue® haemoglobin analyser
title Analysing tropical elasmobranch blood samples in the field: blood stability during storage and validation of the HemoCue® haemoglobin analyser
title_full Analysing tropical elasmobranch blood samples in the field: blood stability during storage and validation of the HemoCue® haemoglobin analyser
title_fullStr Analysing tropical elasmobranch blood samples in the field: blood stability during storage and validation of the HemoCue® haemoglobin analyser
title_full_unstemmed Analysing tropical elasmobranch blood samples in the field: blood stability during storage and validation of the HemoCue® haemoglobin analyser
title_short Analysing tropical elasmobranch blood samples in the field: blood stability during storage and validation of the HemoCue® haemoglobin analyser
title_sort analysing tropical elasmobranch blood samples in the field: blood stability during storage and validation of the hemocue® haemoglobin analyser
topic Toolbox
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6883209/
https://www.ncbi.nlm.nih.gov/pubmed/31803471
http://dx.doi.org/10.1093/conphys/coz081
work_keys_str_mv AT schwietermangaild analysingtropicalelasmobranchbloodsamplesinthefieldbloodstabilityduringstorageandvalidationofthehemocuehaemoglobinanalyser
AT bouyoucosiana analysingtropicalelasmobranchbloodsamplesinthefieldbloodstabilityduringstorageandvalidationofthehemocuehaemoglobinanalyser
AT potgieterkristy analysingtropicalelasmobranchbloodsamplesinthefieldbloodstabilityduringstorageandvalidationofthehemocuehaemoglobinanalyser
AT simpfendorfercolina analysingtropicalelasmobranchbloodsamplesinthefieldbloodstabilityduringstorageandvalidationofthehemocuehaemoglobinanalyser
AT brillrichardw analysingtropicalelasmobranchbloodsamplesinthefieldbloodstabilityduringstorageandvalidationofthehemocuehaemoglobinanalyser
AT rummerjodiel analysingtropicalelasmobranchbloodsamplesinthefieldbloodstabilityduringstorageandvalidationofthehemocuehaemoglobinanalyser