Cargando…

Bracket bonding to polymethylmethacrylate-based materials for computer-aided design/manufacture of temporary restorations: Influence of mechanical treatment and chemical treatment with universal adhesives

OBJECTIVE: To assess shear bond strength and failure mode (Adhesive Remnant Index, ARI) of orthodontic brackets bonded to polymethylmethacrylate (PMMA) blocks for computer-aided design/manufacture (CAD/CAM) fabrication of temporary restorations, following substrate chemical or mechanical treatment....

Descripción completa

Detalles Bibliográficos
Autores principales: Goracci, Cecilia, Özcan, Mutlu, Franchi, Lorenzo, Di Bello, Giuseppe, Louca, Chris, Vichi, Alessandro
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Association of Orthodontists 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6883210/
https://www.ncbi.nlm.nih.gov/pubmed/31815108
http://dx.doi.org/10.4041/kjod.2019.49.6.404
Descripción
Sumario:OBJECTIVE: To assess shear bond strength and failure mode (Adhesive Remnant Index, ARI) of orthodontic brackets bonded to polymethylmethacrylate (PMMA) blocks for computer-aided design/manufacture (CAD/CAM) fabrication of temporary restorations, following substrate chemical or mechanical treatment. METHODS: Two types of PMMA blocks were tested: CAD-Temp® (VITA) and Telio® CAD (Ivoclar-Vivadent). The substrate was roughened with 320-grit sandpaper, simulating a fine-grit diamond bur. Two universal adhesives, Scotchbond Universal Adhesive (SU) and Assure Plus (AP), and a conventional adhesive, Transbond XT Primer (XTP; control), were used in combination with Transbond XT Paste to bond the brackets. Six experimental groups were formed: (1) CADTemp®/SU; (2) CAD-Temp®/AP; (3) CAD-Temp®/XTP; (4) Telio® CAD/SU; (5) Telio® CAD/AP; (6) Telio® CAD/XTP. Shear bond strength and ARI were assessed. On 1 extra block for each PMMA-based material surfaces were roughened with 180-grit sandpaper, simulating a normal/medium-grit (100 mm) diamond bur, and brackets were bonded. Shear bond strengths and ARI scores were compared with those of groups 3, 6. RESULTS: On CAD-Temp® significantly higher bracket bond strengths than on Telio® CAD were recorded. With XTP significantly lower levels of adhesion were reached than using SU or AP. Roughening with a coarser bur resulted in a significant increase in adhesion. CONCLUSIONS: Bracket bonding to CAD/CAM PMMA can be promoted by grinding the substrate with a normal/medium-grit bur or by coating the intact surface with universal adhesives. With appropriate pretreatments, bracket adhesion to CAD/CAM PMMA temporary restorations can be enhanced to clinically satisfactory levels.