Development of a new high sensitivity mechanical switch for augmentative and alternative communication access in people with amyotrophic lateral sclerosis

BACKGROUND: People with Amyotrophic Lateral Sclerosis (PwALS) in the advanced phase are critically affected by an almost total loss of mobility and severe communication problems. Scanning access based on the patient’s interaction with a sensor (or switch) that intercepts even a weak body movement is...

Descripción completa

Detalles Bibliográficos
Autores principales: Caligari, M., Godi, M., Giardini, M., Colombo, R.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6884866/
https://www.ncbi.nlm.nih.gov/pubmed/31783763
http://dx.doi.org/10.1186/s12984-019-0626-5
_version_ 1783474636873269248
author Caligari, M.
Godi, M.
Giardini, M.
Colombo, R.
author_facet Caligari, M.
Godi, M.
Giardini, M.
Colombo, R.
author_sort Caligari, M.
collection PubMed
description BACKGROUND: People with Amyotrophic Lateral Sclerosis (PwALS) in the advanced phase are critically affected by an almost total loss of mobility and severe communication problems. Scanning access based on the patient’s interaction with a sensor (or switch) that intercepts even a weak body movement is a valid communication aid. However, its use becomes limited with the progressive decline of residual movements. To overcome this problem, we designed a new sensor, the Lever Magnetic-spring Mechanical Switch (LeMMS), allowing repeated activation/release cycles requiring a very small activation force. METHODS: The LeMMS was applied and validated in a group of 20 PwALS in an advanced stage of disease. All subjects were regular users of communication aids employing other sensors, but which they could no longer operate their sensors (different from LeMMS). Patients were assessed at baseline (t0) and after one (t1), 6 (t2) and 12 (t3) months. Assessment at t0 included administration of standardized clinical scales, the Click-Test-30 counting the maximum number of LeMMS activations in 30 s, and thumb/fingers strength assessment with the Kendall scale. The QUEST 2.0-Dev questionnaire was administered at t1. Some use-related information and the Click-Test-30 were collected at t1, t2 and t3. RESULTS: After one training session, all patients could operate the LeMMS with minimal residual movement of one finger. At t1, they used it on average 5.45 h/day. The mean score of the QUEST 2.0-Dev was 4.63, suggesting strong satisfaction with the LeMMS. Regarding Click-Test-30 scores, no significant difference was found between t0 and t1, but performance at t2 and t3 declined significantly (p < 0.005 vs. t0). At t3, 9/20 patients were still able to use their communication aid. CONCLUSIONS: This new switch sensor can enable PwALS to use their communication aids for a prolonged time even in the advanced phase of disease. It is easy to use, reliable and cheap, thus representing an intermediate alternative to more sophisticated and costly devices.
format Online
Article
Text
id pubmed-6884866
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-68848662019-12-03 Development of a new high sensitivity mechanical switch for augmentative and alternative communication access in people with amyotrophic lateral sclerosis Caligari, M. Godi, M. Giardini, M. Colombo, R. J Neuroeng Rehabil Research BACKGROUND: People with Amyotrophic Lateral Sclerosis (PwALS) in the advanced phase are critically affected by an almost total loss of mobility and severe communication problems. Scanning access based on the patient’s interaction with a sensor (or switch) that intercepts even a weak body movement is a valid communication aid. However, its use becomes limited with the progressive decline of residual movements. To overcome this problem, we designed a new sensor, the Lever Magnetic-spring Mechanical Switch (LeMMS), allowing repeated activation/release cycles requiring a very small activation force. METHODS: The LeMMS was applied and validated in a group of 20 PwALS in an advanced stage of disease. All subjects were regular users of communication aids employing other sensors, but which they could no longer operate their sensors (different from LeMMS). Patients were assessed at baseline (t0) and after one (t1), 6 (t2) and 12 (t3) months. Assessment at t0 included administration of standardized clinical scales, the Click-Test-30 counting the maximum number of LeMMS activations in 30 s, and thumb/fingers strength assessment with the Kendall scale. The QUEST 2.0-Dev questionnaire was administered at t1. Some use-related information and the Click-Test-30 were collected at t1, t2 and t3. RESULTS: After one training session, all patients could operate the LeMMS with minimal residual movement of one finger. At t1, they used it on average 5.45 h/day. The mean score of the QUEST 2.0-Dev was 4.63, suggesting strong satisfaction with the LeMMS. Regarding Click-Test-30 scores, no significant difference was found between t0 and t1, but performance at t2 and t3 declined significantly (p < 0.005 vs. t0). At t3, 9/20 patients were still able to use their communication aid. CONCLUSIONS: This new switch sensor can enable PwALS to use their communication aids for a prolonged time even in the advanced phase of disease. It is easy to use, reliable and cheap, thus representing an intermediate alternative to more sophisticated and costly devices. BioMed Central 2019-11-29 /pmc/articles/PMC6884866/ /pubmed/31783763 http://dx.doi.org/10.1186/s12984-019-0626-5 Text en © The Author(s). 2019 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Caligari, M.
Godi, M.
Giardini, M.
Colombo, R.
Development of a new high sensitivity mechanical switch for augmentative and alternative communication access in people with amyotrophic lateral sclerosis
title Development of a new high sensitivity mechanical switch for augmentative and alternative communication access in people with amyotrophic lateral sclerosis
title_full Development of a new high sensitivity mechanical switch for augmentative and alternative communication access in people with amyotrophic lateral sclerosis
title_fullStr Development of a new high sensitivity mechanical switch for augmentative and alternative communication access in people with amyotrophic lateral sclerosis
title_full_unstemmed Development of a new high sensitivity mechanical switch for augmentative and alternative communication access in people with amyotrophic lateral sclerosis
title_short Development of a new high sensitivity mechanical switch for augmentative and alternative communication access in people with amyotrophic lateral sclerosis
title_sort development of a new high sensitivity mechanical switch for augmentative and alternative communication access in people with amyotrophic lateral sclerosis
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6884866/
https://www.ncbi.nlm.nih.gov/pubmed/31783763
http://dx.doi.org/10.1186/s12984-019-0626-5
work_keys_str_mv AT caligarim developmentofanewhighsensitivitymechanicalswitchforaugmentativeandalternativecommunicationaccessinpeoplewithamyotrophiclateralsclerosis
AT godim developmentofanewhighsensitivitymechanicalswitchforaugmentativeandalternativecommunicationaccessinpeoplewithamyotrophiclateralsclerosis
AT giardinim developmentofanewhighsensitivitymechanicalswitchforaugmentativeandalternativecommunicationaccessinpeoplewithamyotrophiclateralsclerosis
AT colombor developmentofanewhighsensitivitymechanicalswitchforaugmentativeandalternativecommunicationaccessinpeoplewithamyotrophiclateralsclerosis