The Use of Digital Microscopy to Compare the Thicknesses of Normal Corneas and Ex Vivo Rejected Corneal Grafts with a Focus on the Descemet's Membrane
OBJECTIVE: To compare the thickness of corneal layers, specifically the Descemet's membrane (DM), in normal corneas and in failed grafts due to rejection (FGRs) using the digital histopathology and to propose a model for the measurement of corneal layers using this method. METHODS: This is a pr...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6885265/ https://www.ncbi.nlm.nih.gov/pubmed/31827912 http://dx.doi.org/10.1155/2019/8283175 |
_version_ | 1783474706017419264 |
---|---|
author | Tognon, Taíse Bergeron, Sabrina Mastromonaco, Christina Barella, Kleyton Pasqualotti, Adriano Nunez, Laura Murta, Francisco de Sousa, Luciene Barbosa Campos, Mauro Burnier, Miguel Noel Nascentes |
author_facet | Tognon, Taíse Bergeron, Sabrina Mastromonaco, Christina Barella, Kleyton Pasqualotti, Adriano Nunez, Laura Murta, Francisco de Sousa, Luciene Barbosa Campos, Mauro Burnier, Miguel Noel Nascentes |
author_sort | Tognon, Taíse |
collection | PubMed |
description | OBJECTIVE: To compare the thickness of corneal layers, specifically the Descemet's membrane (DM), in normal corneas and in failed grafts due to rejection (FGRs) using the digital histopathology and to propose a model for the measurement of corneal layers using this method. METHODS: This is a prospective, cross-sectional study performed at the MUHC-McGill University Ocular Pathology & Translational Research Laboratory (McGill University, Montreal, Canada). Histopathological sections of 25 normal human corneas and 40 FGRs were fully digitalized and examined. Inclusion criteria: samples diagnosed as normal corneas or FGRs, from patients older than 18 years of age. Exclusion criteria: histopathological sections without adequate tissue or missing epidemiological information. For each sample, the thicknesses of the epithelium, stroma, and DM were acquired. From a perpendicular plane of reference, two central measurements and two nasal and two temporal peripheral measurements were obtained. RESULTS: There were differences between the normal and FGR groups in the mean central thickness of the epithelium (p < 0.001), the nasal and temporal stromal regions (p < 0.001), and of the DM in the nasal and temporal regions (p < 0.001). Compared with the extremities of the sample (nasal and temporal), the mean thickness of the DM in normal corneas was lower in the central region (p < 0.001), and this difference was not found in the FGR group. CONCLUSIONS: Normal corneas have a thinner epithelium in the central region than the FGR group. In addition, the stroma and DM thicknesses of the nasal and temporal periphery were significantly higher in normal corneas than in those from the FGR group. The digital microscopy protocol applied in this study may be useful for further research studies regarding cornea and other tissues. |
format | Online Article Text |
id | pubmed-6885265 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-68852652019-12-11 The Use of Digital Microscopy to Compare the Thicknesses of Normal Corneas and Ex Vivo Rejected Corneal Grafts with a Focus on the Descemet's Membrane Tognon, Taíse Bergeron, Sabrina Mastromonaco, Christina Barella, Kleyton Pasqualotti, Adriano Nunez, Laura Murta, Francisco de Sousa, Luciene Barbosa Campos, Mauro Burnier, Miguel Noel Nascentes J Ophthalmol Research Article OBJECTIVE: To compare the thickness of corneal layers, specifically the Descemet's membrane (DM), in normal corneas and in failed grafts due to rejection (FGRs) using the digital histopathology and to propose a model for the measurement of corneal layers using this method. METHODS: This is a prospective, cross-sectional study performed at the MUHC-McGill University Ocular Pathology & Translational Research Laboratory (McGill University, Montreal, Canada). Histopathological sections of 25 normal human corneas and 40 FGRs were fully digitalized and examined. Inclusion criteria: samples diagnosed as normal corneas or FGRs, from patients older than 18 years of age. Exclusion criteria: histopathological sections without adequate tissue or missing epidemiological information. For each sample, the thicknesses of the epithelium, stroma, and DM were acquired. From a perpendicular plane of reference, two central measurements and two nasal and two temporal peripheral measurements were obtained. RESULTS: There were differences between the normal and FGR groups in the mean central thickness of the epithelium (p < 0.001), the nasal and temporal stromal regions (p < 0.001), and of the DM in the nasal and temporal regions (p < 0.001). Compared with the extremities of the sample (nasal and temporal), the mean thickness of the DM in normal corneas was lower in the central region (p < 0.001), and this difference was not found in the FGR group. CONCLUSIONS: Normal corneas have a thinner epithelium in the central region than the FGR group. In addition, the stroma and DM thicknesses of the nasal and temporal periphery were significantly higher in normal corneas than in those from the FGR group. The digital microscopy protocol applied in this study may be useful for further research studies regarding cornea and other tissues. Hindawi 2019-11-15 /pmc/articles/PMC6885265/ /pubmed/31827912 http://dx.doi.org/10.1155/2019/8283175 Text en Copyright © 2019 Taíse Tognon et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Tognon, Taíse Bergeron, Sabrina Mastromonaco, Christina Barella, Kleyton Pasqualotti, Adriano Nunez, Laura Murta, Francisco de Sousa, Luciene Barbosa Campos, Mauro Burnier, Miguel Noel Nascentes The Use of Digital Microscopy to Compare the Thicknesses of Normal Corneas and Ex Vivo Rejected Corneal Grafts with a Focus on the Descemet's Membrane |
title | The Use of Digital Microscopy to Compare the Thicknesses of Normal Corneas and Ex Vivo Rejected Corneal Grafts with a Focus on the Descemet's Membrane |
title_full | The Use of Digital Microscopy to Compare the Thicknesses of Normal Corneas and Ex Vivo Rejected Corneal Grafts with a Focus on the Descemet's Membrane |
title_fullStr | The Use of Digital Microscopy to Compare the Thicknesses of Normal Corneas and Ex Vivo Rejected Corneal Grafts with a Focus on the Descemet's Membrane |
title_full_unstemmed | The Use of Digital Microscopy to Compare the Thicknesses of Normal Corneas and Ex Vivo Rejected Corneal Grafts with a Focus on the Descemet's Membrane |
title_short | The Use of Digital Microscopy to Compare the Thicknesses of Normal Corneas and Ex Vivo Rejected Corneal Grafts with a Focus on the Descemet's Membrane |
title_sort | use of digital microscopy to compare the thicknesses of normal corneas and ex vivo rejected corneal grafts with a focus on the descemet's membrane |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6885265/ https://www.ncbi.nlm.nih.gov/pubmed/31827912 http://dx.doi.org/10.1155/2019/8283175 |
work_keys_str_mv | AT tognontaise theuseofdigitalmicroscopytocomparethethicknessesofnormalcorneasandexvivorejectedcornealgraftswithafocusonthedescemetsmembrane AT bergeronsabrina theuseofdigitalmicroscopytocomparethethicknessesofnormalcorneasandexvivorejectedcornealgraftswithafocusonthedescemetsmembrane AT mastromonacochristina theuseofdigitalmicroscopytocomparethethicknessesofnormalcorneasandexvivorejectedcornealgraftswithafocusonthedescemetsmembrane AT barellakleyton theuseofdigitalmicroscopytocomparethethicknessesofnormalcorneasandexvivorejectedcornealgraftswithafocusonthedescemetsmembrane AT pasqualottiadriano theuseofdigitalmicroscopytocomparethethicknessesofnormalcorneasandexvivorejectedcornealgraftswithafocusonthedescemetsmembrane AT nunezlaura theuseofdigitalmicroscopytocomparethethicknessesofnormalcorneasandexvivorejectedcornealgraftswithafocusonthedescemetsmembrane AT murtafrancisco theuseofdigitalmicroscopytocomparethethicknessesofnormalcorneasandexvivorejectedcornealgraftswithafocusonthedescemetsmembrane AT desousalucienebarbosa theuseofdigitalmicroscopytocomparethethicknessesofnormalcorneasandexvivorejectedcornealgraftswithafocusonthedescemetsmembrane AT camposmauro theuseofdigitalmicroscopytocomparethethicknessesofnormalcorneasandexvivorejectedcornealgraftswithafocusonthedescemetsmembrane AT burniermiguelnoelnascentes theuseofdigitalmicroscopytocomparethethicknessesofnormalcorneasandexvivorejectedcornealgraftswithafocusonthedescemetsmembrane AT tognontaise useofdigitalmicroscopytocomparethethicknessesofnormalcorneasandexvivorejectedcornealgraftswithafocusonthedescemetsmembrane AT bergeronsabrina useofdigitalmicroscopytocomparethethicknessesofnormalcorneasandexvivorejectedcornealgraftswithafocusonthedescemetsmembrane AT mastromonacochristina useofdigitalmicroscopytocomparethethicknessesofnormalcorneasandexvivorejectedcornealgraftswithafocusonthedescemetsmembrane AT barellakleyton useofdigitalmicroscopytocomparethethicknessesofnormalcorneasandexvivorejectedcornealgraftswithafocusonthedescemetsmembrane AT pasqualottiadriano useofdigitalmicroscopytocomparethethicknessesofnormalcorneasandexvivorejectedcornealgraftswithafocusonthedescemetsmembrane AT nunezlaura useofdigitalmicroscopytocomparethethicknessesofnormalcorneasandexvivorejectedcornealgraftswithafocusonthedescemetsmembrane AT murtafrancisco useofdigitalmicroscopytocomparethethicknessesofnormalcorneasandexvivorejectedcornealgraftswithafocusonthedescemetsmembrane AT desousalucienebarbosa useofdigitalmicroscopytocomparethethicknessesofnormalcorneasandexvivorejectedcornealgraftswithafocusonthedescemetsmembrane AT camposmauro useofdigitalmicroscopytocomparethethicknessesofnormalcorneasandexvivorejectedcornealgraftswithafocusonthedescemetsmembrane AT burniermiguelnoelnascentes useofdigitalmicroscopytocomparethethicknessesofnormalcorneasandexvivorejectedcornealgraftswithafocusonthedescemetsmembrane |