Cargando…

Determinants and outcome of repeat continuous electroencephalogram monitoring—A case‐control study

OBJECTIVE: A retrospective, single‐center study to analyze the determinants of a repeat continuous EEG (cEEG) monitoring during hospitalization and its outcomes using a matched case‐control study design. METHODS: Adults with a repeat cEEG session (cases) were matched by age (±3 years), gender, and m...

Descripción completa

Detalles Bibliográficos
Autores principales: Punia, Vineet, Zawar, Ifrah, Briskin, Isaac, Burgess, Richard, Newey, Christopher R., Hantus, Stephen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6885659/
https://www.ncbi.nlm.nih.gov/pubmed/31819913
http://dx.doi.org/10.1002/epi4.12361
_version_ 1783474764783812608
author Punia, Vineet
Zawar, Ifrah
Briskin, Isaac
Burgess, Richard
Newey, Christopher R.
Hantus, Stephen
author_facet Punia, Vineet
Zawar, Ifrah
Briskin, Isaac
Burgess, Richard
Newey, Christopher R.
Hantus, Stephen
author_sort Punia, Vineet
collection PubMed
description OBJECTIVE: A retrospective, single‐center study to analyze the determinants of a repeat continuous EEG (cEEG) monitoring during hospitalization and its outcomes using a matched case‐control study design. METHODS: Adults with a repeat cEEG session (cases) were matched by age (±3 years), gender, and mental status to patients with a single cEEG (controls) during hospitalization. Several clinical and EEG characteristics were analyzed to identify predictors of repeat cEEG. Repeat cEEG outcomes were analyzed based on its yield of electrographic seizure. We investigated the predictors of finding increased epileptic potential (degree of association with electrographic seizures) on the repeat cEEG, a marker for possible anti‐epileptic drugs (AEDs) management change. RESULTS: A total of 213 (8.6% of all unique cEEG patients) cases were included. A multivariable conditional logistic regression model comparing cases and controls showed that the presence of acute brain insult [odds ratio (OR) = 3.36, 95% CI = 1.26‐8.94, P = .015], longer hospital admission (OR = 1.11, 95% CI = 1.07‐1.15, P < .001) and being on AEDs at the end of index cEEG (OR = 4.0, 95% CI = 1.8‐8.87, P < .001) was determinants of a repeat cEEG. Among cases, 17 (8%) had electrographic seizures on repeat cEEG. Increased epileptic potential on repeat cEEG was noted in 34 (16%) cases. The latter is associated with change in etiology after the index cEEG (P = .03) and duration of repeat cEEG (P = .003) based on multivariable logistic regression model. AEDs were changed in 46 (21.6%) patients based on repeat cEEG findings. SIGNIFICANCE: Repeat cEEG is not an uncommon practice. It leads to the diagnosis of electrographic seizures in a significant percentage of patients. With the potential of impacting AED management in 16%‐21% patients, it should be considered in high‐risk patients suffering acute brain insults undergoing prolonged hospitalization.
format Online
Article
Text
id pubmed-6885659
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-68856592019-12-09 Determinants and outcome of repeat continuous electroencephalogram monitoring—A case‐control study Punia, Vineet Zawar, Ifrah Briskin, Isaac Burgess, Richard Newey, Christopher R. Hantus, Stephen Epilepsia Open Full‐length Original Research OBJECTIVE: A retrospective, single‐center study to analyze the determinants of a repeat continuous EEG (cEEG) monitoring during hospitalization and its outcomes using a matched case‐control study design. METHODS: Adults with a repeat cEEG session (cases) were matched by age (±3 years), gender, and mental status to patients with a single cEEG (controls) during hospitalization. Several clinical and EEG characteristics were analyzed to identify predictors of repeat cEEG. Repeat cEEG outcomes were analyzed based on its yield of electrographic seizure. We investigated the predictors of finding increased epileptic potential (degree of association with electrographic seizures) on the repeat cEEG, a marker for possible anti‐epileptic drugs (AEDs) management change. RESULTS: A total of 213 (8.6% of all unique cEEG patients) cases were included. A multivariable conditional logistic regression model comparing cases and controls showed that the presence of acute brain insult [odds ratio (OR) = 3.36, 95% CI = 1.26‐8.94, P = .015], longer hospital admission (OR = 1.11, 95% CI = 1.07‐1.15, P < .001) and being on AEDs at the end of index cEEG (OR = 4.0, 95% CI = 1.8‐8.87, P < .001) was determinants of a repeat cEEG. Among cases, 17 (8%) had electrographic seizures on repeat cEEG. Increased epileptic potential on repeat cEEG was noted in 34 (16%) cases. The latter is associated with change in etiology after the index cEEG (P = .03) and duration of repeat cEEG (P = .003) based on multivariable logistic regression model. AEDs were changed in 46 (21.6%) patients based on repeat cEEG findings. SIGNIFICANCE: Repeat cEEG is not an uncommon practice. It leads to the diagnosis of electrographic seizures in a significant percentage of patients. With the potential of impacting AED management in 16%‐21% patients, it should be considered in high‐risk patients suffering acute brain insults undergoing prolonged hospitalization. John Wiley and Sons Inc. 2019-09-23 /pmc/articles/PMC6885659/ /pubmed/31819913 http://dx.doi.org/10.1002/epi4.12361 Text en © 2019 The Authors. Epilepsia Open published by Wiley Periodicals Inc. on behalf of International League Against Epilepsy This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
spellingShingle Full‐length Original Research
Punia, Vineet
Zawar, Ifrah
Briskin, Isaac
Burgess, Richard
Newey, Christopher R.
Hantus, Stephen
Determinants and outcome of repeat continuous electroencephalogram monitoring—A case‐control study
title Determinants and outcome of repeat continuous electroencephalogram monitoring—A case‐control study
title_full Determinants and outcome of repeat continuous electroencephalogram monitoring—A case‐control study
title_fullStr Determinants and outcome of repeat continuous electroencephalogram monitoring—A case‐control study
title_full_unstemmed Determinants and outcome of repeat continuous electroencephalogram monitoring—A case‐control study
title_short Determinants and outcome of repeat continuous electroencephalogram monitoring—A case‐control study
title_sort determinants and outcome of repeat continuous electroencephalogram monitoring—a case‐control study
topic Full‐length Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6885659/
https://www.ncbi.nlm.nih.gov/pubmed/31819913
http://dx.doi.org/10.1002/epi4.12361
work_keys_str_mv AT puniavineet determinantsandoutcomeofrepeatcontinuouselectroencephalogrammonitoringacasecontrolstudy
AT zawarifrah determinantsandoutcomeofrepeatcontinuouselectroencephalogrammonitoringacasecontrolstudy
AT briskinisaac determinantsandoutcomeofrepeatcontinuouselectroencephalogrammonitoringacasecontrolstudy
AT burgessrichard determinantsandoutcomeofrepeatcontinuouselectroencephalogrammonitoringacasecontrolstudy
AT neweychristopherr determinantsandoutcomeofrepeatcontinuouselectroencephalogrammonitoringacasecontrolstudy
AT hantusstephen determinantsandoutcomeofrepeatcontinuouselectroencephalogrammonitoringacasecontrolstudy