Cargando…
Donor-site Morbidity after Retromolar Bone Harvesting Using a Standardised Press Fit Cylinder Protocol
Precise fitting and immobilisation of bone transplants at the recipient site is of utmost importance for the healing process. With the help of the standardised Osseo Transfer System, the recipient site is adjusted to the graft, rather than vice versa as it is typically done. The aim of this study wa...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6887743/ https://www.ncbi.nlm.nih.gov/pubmed/31752347 http://dx.doi.org/10.3390/ma12223802 |
_version_ | 1783475080175550464 |
---|---|
author | Streckbein, Philipp Meier, Mathias Kähling, Christopher Wilbrand, Jan-Falco Langguth, Tobias Schaaf, Heidrun Howaldt, Hans-Peter Streckbein, Roland Attia, Sameh |
author_facet | Streckbein, Philipp Meier, Mathias Kähling, Christopher Wilbrand, Jan-Falco Langguth, Tobias Schaaf, Heidrun Howaldt, Hans-Peter Streckbein, Roland Attia, Sameh |
author_sort | Streckbein, Philipp |
collection | PubMed |
description | Precise fitting and immobilisation of bone transplants at the recipient site is of utmost importance for the healing process. With the help of the standardised Osseo Transfer System, the recipient site is adjusted to the graft, rather than vice versa as it is typically done. The aim of this study was to analyse donor-site morbidity after harvesting cylindrical bone grafts from the retromolar region using the Osseo Transfer System. The patient satisfaction with the surgical procedures was also evaluated. All patients treated with this standardised reconstruction method between 2006 and 2013 at the Department of Cranio-Maxillofacial Surgery, University Hospital Giessen, were included in this study. Complications were recorded and evaluated. Bone graft success and patient satisfaction were documented with a questionnaire, and then confirmed by clinical and radiological follow-up examinations. Fifty-four patients were treated and 64 harvested cylindrical autologous bone grafts were transplanted. In all cases, dental implants could be inserted after bone healing. One patient lost an implant, associated with failure of the bone graft. Six patients who were examined continued to show neurological disorders in locally limited areas. No complete or long-term damage of the inferior alveolar nerve occurred. More than 94% (n = 52) of the patients were ‘very satisfied’ or ‘satisfied’ with the results and would recommend this surgical treatment to other patients. The standardised Osseo Transfer was an effective treatment option for small and mid-sized alveolar ridge augmentations. A low donor-site morbidity rate and a high transplant success rate were verified. The Osseo Transfer System demonstrated to be a reliable surgical technique without major complications. We highly recommend this surgical augmentation procedure as a surgical treatment for local bone defects. |
format | Online Article Text |
id | pubmed-6887743 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-68877432019-12-09 Donor-site Morbidity after Retromolar Bone Harvesting Using a Standardised Press Fit Cylinder Protocol Streckbein, Philipp Meier, Mathias Kähling, Christopher Wilbrand, Jan-Falco Langguth, Tobias Schaaf, Heidrun Howaldt, Hans-Peter Streckbein, Roland Attia, Sameh Materials (Basel) Article Precise fitting and immobilisation of bone transplants at the recipient site is of utmost importance for the healing process. With the help of the standardised Osseo Transfer System, the recipient site is adjusted to the graft, rather than vice versa as it is typically done. The aim of this study was to analyse donor-site morbidity after harvesting cylindrical bone grafts from the retromolar region using the Osseo Transfer System. The patient satisfaction with the surgical procedures was also evaluated. All patients treated with this standardised reconstruction method between 2006 and 2013 at the Department of Cranio-Maxillofacial Surgery, University Hospital Giessen, were included in this study. Complications were recorded and evaluated. Bone graft success and patient satisfaction were documented with a questionnaire, and then confirmed by clinical and radiological follow-up examinations. Fifty-four patients were treated and 64 harvested cylindrical autologous bone grafts were transplanted. In all cases, dental implants could be inserted after bone healing. One patient lost an implant, associated with failure of the bone graft. Six patients who were examined continued to show neurological disorders in locally limited areas. No complete or long-term damage of the inferior alveolar nerve occurred. More than 94% (n = 52) of the patients were ‘very satisfied’ or ‘satisfied’ with the results and would recommend this surgical treatment to other patients. The standardised Osseo Transfer was an effective treatment option for small and mid-sized alveolar ridge augmentations. A low donor-site morbidity rate and a high transplant success rate were verified. The Osseo Transfer System demonstrated to be a reliable surgical technique without major complications. We highly recommend this surgical augmentation procedure as a surgical treatment for local bone defects. MDPI 2019-11-19 /pmc/articles/PMC6887743/ /pubmed/31752347 http://dx.doi.org/10.3390/ma12223802 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Streckbein, Philipp Meier, Mathias Kähling, Christopher Wilbrand, Jan-Falco Langguth, Tobias Schaaf, Heidrun Howaldt, Hans-Peter Streckbein, Roland Attia, Sameh Donor-site Morbidity after Retromolar Bone Harvesting Using a Standardised Press Fit Cylinder Protocol |
title | Donor-site Morbidity after Retromolar Bone Harvesting Using a Standardised Press Fit Cylinder Protocol |
title_full | Donor-site Morbidity after Retromolar Bone Harvesting Using a Standardised Press Fit Cylinder Protocol |
title_fullStr | Donor-site Morbidity after Retromolar Bone Harvesting Using a Standardised Press Fit Cylinder Protocol |
title_full_unstemmed | Donor-site Morbidity after Retromolar Bone Harvesting Using a Standardised Press Fit Cylinder Protocol |
title_short | Donor-site Morbidity after Retromolar Bone Harvesting Using a Standardised Press Fit Cylinder Protocol |
title_sort | donor-site morbidity after retromolar bone harvesting using a standardised press fit cylinder protocol |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6887743/ https://www.ncbi.nlm.nih.gov/pubmed/31752347 http://dx.doi.org/10.3390/ma12223802 |
work_keys_str_mv | AT streckbeinphilipp donorsitemorbidityafterretromolarboneharvestingusingastandardisedpressfitcylinderprotocol AT meiermathias donorsitemorbidityafterretromolarboneharvestingusingastandardisedpressfitcylinderprotocol AT kahlingchristopher donorsitemorbidityafterretromolarboneharvestingusingastandardisedpressfitcylinderprotocol AT wilbrandjanfalco donorsitemorbidityafterretromolarboneharvestingusingastandardisedpressfitcylinderprotocol AT langguthtobias donorsitemorbidityafterretromolarboneharvestingusingastandardisedpressfitcylinderprotocol AT schaafheidrun donorsitemorbidityafterretromolarboneharvestingusingastandardisedpressfitcylinderprotocol AT howaldthanspeter donorsitemorbidityafterretromolarboneharvestingusingastandardisedpressfitcylinderprotocol AT streckbeinroland donorsitemorbidityafterretromolarboneharvestingusingastandardisedpressfitcylinderprotocol AT attiasameh donorsitemorbidityafterretromolarboneharvestingusingastandardisedpressfitcylinderprotocol |