Cargando…
Clinical Outcomes of Penetrating Keratoplasty and Descemet Stripping Automated Endothelial Keratoplasty in Asian Population with American Corneas
To determine the comparative efficacy and safety of penetrating keratoplasty (PK) and Descemet stripping automated endothelial keratoplasty (DSAEK) in the Asian population receiving imported donor corneas, our single-center retrospective study provides analysis supporting the transition from PK to D...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6888050/ https://www.ncbi.nlm.nih.gov/pubmed/31744259 http://dx.doi.org/10.3390/ijerph16224547 |
_version_ | 1783475140317675520 |
---|---|
author | Hsiao, Fang-Chi Chen, Po-Yuan Meir, Yaa-Jyuhn James Tan, Hsin-Yuan Hsiao, Ching-Hsi Lin, Hsin-Chiung Ma, David Hui-Kang Yeh, Lung-Kun Wu, Wei-Chi Chen, Hung-Chi |
author_facet | Hsiao, Fang-Chi Chen, Po-Yuan Meir, Yaa-Jyuhn James Tan, Hsin-Yuan Hsiao, Ching-Hsi Lin, Hsin-Chiung Ma, David Hui-Kang Yeh, Lung-Kun Wu, Wei-Chi Chen, Hung-Chi |
author_sort | Hsiao, Fang-Chi |
collection | PubMed |
description | To determine the comparative efficacy and safety of penetrating keratoplasty (PK) and Descemet stripping automated endothelial keratoplasty (DSAEK) in the Asian population receiving imported donor corneas, our single-center retrospective study provides analysis supporting the transition from PK to DSAEK in the Asian population using imported American donor corneas. We analyzed 259 patients with 241 and 57 cases of PK and DSAEK respectively during 2008 to 2017 using imported corneas at Chang Gung Memorial Hospital, Linkou, Taiwan. In terms of long-term graft survival analysis, there was no difference between PK and DSAEK (log-rank p = 0.386, HR = 0.920, 95% CI: [0.641–1.380]). However, Cox proportional regression analysis revealed that corneal survival rate of DSAEK group in the first 100 days after transplantation was inferior than that of PK group (log-rank p < 0.001, HR = 2.733, 95% CI: [1.501–4.977])]. Despite the inferior survival rate, there were significantly less neovascularization and Descemet membrane folds in the DSAEK group. Importantly, the non-complication rate of DSAEK was much higher than that of PK with significant difference (PK, 25.7% vs. DSAEK 42.0%, p = 0.022). Collectively, DSAEK is suggested as an alternative surgical modality in Asian patients using imported American donor corneas because of less complication, and no difference in long-term corneal graft survival rates between PK and DSAEK. |
format | Online Article Text |
id | pubmed-6888050 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-68880502019-12-09 Clinical Outcomes of Penetrating Keratoplasty and Descemet Stripping Automated Endothelial Keratoplasty in Asian Population with American Corneas Hsiao, Fang-Chi Chen, Po-Yuan Meir, Yaa-Jyuhn James Tan, Hsin-Yuan Hsiao, Ching-Hsi Lin, Hsin-Chiung Ma, David Hui-Kang Yeh, Lung-Kun Wu, Wei-Chi Chen, Hung-Chi Int J Environ Res Public Health Article To determine the comparative efficacy and safety of penetrating keratoplasty (PK) and Descemet stripping automated endothelial keratoplasty (DSAEK) in the Asian population receiving imported donor corneas, our single-center retrospective study provides analysis supporting the transition from PK to DSAEK in the Asian population using imported American donor corneas. We analyzed 259 patients with 241 and 57 cases of PK and DSAEK respectively during 2008 to 2017 using imported corneas at Chang Gung Memorial Hospital, Linkou, Taiwan. In terms of long-term graft survival analysis, there was no difference between PK and DSAEK (log-rank p = 0.386, HR = 0.920, 95% CI: [0.641–1.380]). However, Cox proportional regression analysis revealed that corneal survival rate of DSAEK group in the first 100 days after transplantation was inferior than that of PK group (log-rank p < 0.001, HR = 2.733, 95% CI: [1.501–4.977])]. Despite the inferior survival rate, there were significantly less neovascularization and Descemet membrane folds in the DSAEK group. Importantly, the non-complication rate of DSAEK was much higher than that of PK with significant difference (PK, 25.7% vs. DSAEK 42.0%, p = 0.022). Collectively, DSAEK is suggested as an alternative surgical modality in Asian patients using imported American donor corneas because of less complication, and no difference in long-term corneal graft survival rates between PK and DSAEK. MDPI 2019-11-17 2019-11 /pmc/articles/PMC6888050/ /pubmed/31744259 http://dx.doi.org/10.3390/ijerph16224547 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Hsiao, Fang-Chi Chen, Po-Yuan Meir, Yaa-Jyuhn James Tan, Hsin-Yuan Hsiao, Ching-Hsi Lin, Hsin-Chiung Ma, David Hui-Kang Yeh, Lung-Kun Wu, Wei-Chi Chen, Hung-Chi Clinical Outcomes of Penetrating Keratoplasty and Descemet Stripping Automated Endothelial Keratoplasty in Asian Population with American Corneas |
title | Clinical Outcomes of Penetrating Keratoplasty and Descemet Stripping Automated Endothelial Keratoplasty in Asian Population with American Corneas |
title_full | Clinical Outcomes of Penetrating Keratoplasty and Descemet Stripping Automated Endothelial Keratoplasty in Asian Population with American Corneas |
title_fullStr | Clinical Outcomes of Penetrating Keratoplasty and Descemet Stripping Automated Endothelial Keratoplasty in Asian Population with American Corneas |
title_full_unstemmed | Clinical Outcomes of Penetrating Keratoplasty and Descemet Stripping Automated Endothelial Keratoplasty in Asian Population with American Corneas |
title_short | Clinical Outcomes of Penetrating Keratoplasty and Descemet Stripping Automated Endothelial Keratoplasty in Asian Population with American Corneas |
title_sort | clinical outcomes of penetrating keratoplasty and descemet stripping automated endothelial keratoplasty in asian population with american corneas |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6888050/ https://www.ncbi.nlm.nih.gov/pubmed/31744259 http://dx.doi.org/10.3390/ijerph16224547 |
work_keys_str_mv | AT hsiaofangchi clinicaloutcomesofpenetratingkeratoplastyanddescemetstrippingautomatedendothelialkeratoplastyinasianpopulationwithamericancorneas AT chenpoyuan clinicaloutcomesofpenetratingkeratoplastyanddescemetstrippingautomatedendothelialkeratoplastyinasianpopulationwithamericancorneas AT meiryaajyuhnjames clinicaloutcomesofpenetratingkeratoplastyanddescemetstrippingautomatedendothelialkeratoplastyinasianpopulationwithamericancorneas AT tanhsinyuan clinicaloutcomesofpenetratingkeratoplastyanddescemetstrippingautomatedendothelialkeratoplastyinasianpopulationwithamericancorneas AT hsiaochinghsi clinicaloutcomesofpenetratingkeratoplastyanddescemetstrippingautomatedendothelialkeratoplastyinasianpopulationwithamericancorneas AT linhsinchiung clinicaloutcomesofpenetratingkeratoplastyanddescemetstrippingautomatedendothelialkeratoplastyinasianpopulationwithamericancorneas AT madavidhuikang clinicaloutcomesofpenetratingkeratoplastyanddescemetstrippingautomatedendothelialkeratoplastyinasianpopulationwithamericancorneas AT yehlungkun clinicaloutcomesofpenetratingkeratoplastyanddescemetstrippingautomatedendothelialkeratoplastyinasianpopulationwithamericancorneas AT wuweichi clinicaloutcomesofpenetratingkeratoplastyanddescemetstrippingautomatedendothelialkeratoplastyinasianpopulationwithamericancorneas AT chenhungchi clinicaloutcomesofpenetratingkeratoplastyanddescemetstrippingautomatedendothelialkeratoplastyinasianpopulationwithamericancorneas |