Cargando…

A standardized methodology for longitudinal assessment of corneal endothelial morphometry in eye banked corneas

Eye banked research-grade human donor corneas serve as principal ex vivo source for studying the mechanisms that underlie corneal endothelial cell damage/death and survival. Wide-field specular microscopy can be used for corneal endothelial visualization and allows for indirect assessment of endothe...

Descripción completa

Detalles Bibliográficos
Autores principales: Lužnik, Zala, Sun, Zhongmou, Yin, Jia, Benetz, Beth Ann, Lass, Jonathan H., Dana, Reza
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Journal of Biological Methods 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6888603/
https://www.ncbi.nlm.nih.gov/pubmed/31890720
http://dx.doi.org/10.14440/jbm.2019.304
_version_ 1783475269558861824
author Lužnik, Zala
Sun, Zhongmou
Yin, Jia
Benetz, Beth Ann
Lass, Jonathan H.
Dana, Reza
author_facet Lužnik, Zala
Sun, Zhongmou
Yin, Jia
Benetz, Beth Ann
Lass, Jonathan H.
Dana, Reza
author_sort Lužnik, Zala
collection PubMed
description Eye banked research-grade human donor corneas serve as principal ex vivo source for studying the mechanisms that underlie corneal endothelial cell damage/death and survival. Wide-field specular microscopy can be used for corneal endothelial visualization and allows for indirect assessment of endothelial cell function by analyzing endothelial cell density and morphometric parameters. However, a standardized approach is needed to observe corneal endothelial changes over time. This protocol describes reliable ex vivo methods for consecutive analyses of human donor corneal endothelial cell density and morphometric parameters change using a wide-field dual imaging specular microscope. This protocol involves tissue warming, acquisition and analysis of specular endothelial images, assessment of corneal layers with the new Enhance mode, optical pachymetry measurement, and qualitative image quality grading scales. This quantitative and qualitative evaluation of donor corneas allows for a systematic analysis of endothelial dynamic responses to ex vivo induced stress and can be used as a valuable tool to better elucidate specular findings and mechanisms mediating corneal endothelial cell loss in corneal disease and after transplantation.
format Online
Article
Text
id pubmed-6888603
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Journal of Biological Methods
record_format MEDLINE/PubMed
spelling pubmed-68886032019-12-30 A standardized methodology for longitudinal assessment of corneal endothelial morphometry in eye banked corneas Lužnik, Zala Sun, Zhongmou Yin, Jia Benetz, Beth Ann Lass, Jonathan H. Dana, Reza J Biol Methods Protocol Eye banked research-grade human donor corneas serve as principal ex vivo source for studying the mechanisms that underlie corneal endothelial cell damage/death and survival. Wide-field specular microscopy can be used for corneal endothelial visualization and allows for indirect assessment of endothelial cell function by analyzing endothelial cell density and morphometric parameters. However, a standardized approach is needed to observe corneal endothelial changes over time. This protocol describes reliable ex vivo methods for consecutive analyses of human donor corneal endothelial cell density and morphometric parameters change using a wide-field dual imaging specular microscope. This protocol involves tissue warming, acquisition and analysis of specular endothelial images, assessment of corneal layers with the new Enhance mode, optical pachymetry measurement, and qualitative image quality grading scales. This quantitative and qualitative evaluation of donor corneas allows for a systematic analysis of endothelial dynamic responses to ex vivo induced stress and can be used as a valuable tool to better elucidate specular findings and mechanisms mediating corneal endothelial cell loss in corneal disease and after transplantation. Journal of Biological Methods 2019-11-20 /pmc/articles/PMC6888603/ /pubmed/31890720 http://dx.doi.org/10.14440/jbm.2019.304 Text en © 2013-2019 The Journal of Biological Methods, All rights reserved. http://creativecommons.org/licenses/by-nc-sa/4.0 This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License: http://creativecommons.org/licenses/by-nc-sa/4.0
spellingShingle Protocol
Lužnik, Zala
Sun, Zhongmou
Yin, Jia
Benetz, Beth Ann
Lass, Jonathan H.
Dana, Reza
A standardized methodology for longitudinal assessment of corneal endothelial morphometry in eye banked corneas
title A standardized methodology for longitudinal assessment of corneal endothelial morphometry in eye banked corneas
title_full A standardized methodology for longitudinal assessment of corneal endothelial morphometry in eye banked corneas
title_fullStr A standardized methodology for longitudinal assessment of corneal endothelial morphometry in eye banked corneas
title_full_unstemmed A standardized methodology for longitudinal assessment of corneal endothelial morphometry in eye banked corneas
title_short A standardized methodology for longitudinal assessment of corneal endothelial morphometry in eye banked corneas
title_sort standardized methodology for longitudinal assessment of corneal endothelial morphometry in eye banked corneas
topic Protocol
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6888603/
https://www.ncbi.nlm.nih.gov/pubmed/31890720
http://dx.doi.org/10.14440/jbm.2019.304
work_keys_str_mv AT luznikzala astandardizedmethodologyforlongitudinalassessmentofcornealendothelialmorphometryineyebankedcorneas
AT sunzhongmou astandardizedmethodologyforlongitudinalassessmentofcornealendothelialmorphometryineyebankedcorneas
AT yinjia astandardizedmethodologyforlongitudinalassessmentofcornealendothelialmorphometryineyebankedcorneas
AT benetzbethann astandardizedmethodologyforlongitudinalassessmentofcornealendothelialmorphometryineyebankedcorneas
AT lassjonathanh astandardizedmethodologyforlongitudinalassessmentofcornealendothelialmorphometryineyebankedcorneas
AT danareza astandardizedmethodologyforlongitudinalassessmentofcornealendothelialmorphometryineyebankedcorneas
AT luznikzala standardizedmethodologyforlongitudinalassessmentofcornealendothelialmorphometryineyebankedcorneas
AT sunzhongmou standardizedmethodologyforlongitudinalassessmentofcornealendothelialmorphometryineyebankedcorneas
AT yinjia standardizedmethodologyforlongitudinalassessmentofcornealendothelialmorphometryineyebankedcorneas
AT benetzbethann standardizedmethodologyforlongitudinalassessmentofcornealendothelialmorphometryineyebankedcorneas
AT lassjonathanh standardizedmethodologyforlongitudinalassessmentofcornealendothelialmorphometryineyebankedcorneas
AT danareza standardizedmethodologyforlongitudinalassessmentofcornealendothelialmorphometryineyebankedcorneas