The microtensile bond strength test: Its historical background and application to bond testing

Microtensile bond strength (μTBS) test was introduced in 1994. Since then, it has been utilized profoundly across many bond strength testing laboratories, making it currently one of the most standard and versatile bond strength test. Although it is a static and strength-based method, together with t...

Descripción completa

Detalles Bibliográficos
Autores principales: Sano, Hidehiko, Chowdhury, Abu Faem Mohammad Almas, Saikaew, Pipop, Matsumoto, Mariko, Hoshika, Shuhei, Yamauti, Monica
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6888711/
https://www.ncbi.nlm.nih.gov/pubmed/31827652
http://dx.doi.org/10.1016/j.jdsr.2019.10.001
_version_ 1783475293612146688
author Sano, Hidehiko
Chowdhury, Abu Faem Mohammad Almas
Saikaew, Pipop
Matsumoto, Mariko
Hoshika, Shuhei
Yamauti, Monica
author_facet Sano, Hidehiko
Chowdhury, Abu Faem Mohammad Almas
Saikaew, Pipop
Matsumoto, Mariko
Hoshika, Shuhei
Yamauti, Monica
author_sort Sano, Hidehiko
collection PubMed
description Microtensile bond strength (μTBS) test was introduced in 1994. Since then, it has been utilized profoundly across many bond strength testing laboratories, making it currently one of the most standard and versatile bond strength test. Although it is a static and strength-based method, together with the morphological and spectroscopic investigations, it has been contributing immensely in the advancement of dentin adhesive systems. μTBS test has a greater discriminative capability than the traditional macro-shear bond test. During the early stage of its development, the authors predicted that this testing method would enable evaluation of the adhesive performances of resins to excavated carious or sclerotic dentin and the regional bond strengths of various portions of the cavity. In addition, they also stated the possibility of comparing the long-term stability of resin adhesion at various portions of the cavity walls on teeth extracted at various times after insertion of bonded restorations. In this review, we discussed the historical background, inception and the application of the μTBS test and proposed directions for further improvement of this testing method.
format Online
Article
Text
id pubmed-6888711
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-68887112019-12-11 The microtensile bond strength test: Its historical background and application to bond testing Sano, Hidehiko Chowdhury, Abu Faem Mohammad Almas Saikaew, Pipop Matsumoto, Mariko Hoshika, Shuhei Yamauti, Monica Jpn Dent Sci Rev Article Microtensile bond strength (μTBS) test was introduced in 1994. Since then, it has been utilized profoundly across many bond strength testing laboratories, making it currently one of the most standard and versatile bond strength test. Although it is a static and strength-based method, together with the morphological and spectroscopic investigations, it has been contributing immensely in the advancement of dentin adhesive systems. μTBS test has a greater discriminative capability than the traditional macro-shear bond test. During the early stage of its development, the authors predicted that this testing method would enable evaluation of the adhesive performances of resins to excavated carious or sclerotic dentin and the regional bond strengths of various portions of the cavity. In addition, they also stated the possibility of comparing the long-term stability of resin adhesion at various portions of the cavity walls on teeth extracted at various times after insertion of bonded restorations. In this review, we discussed the historical background, inception and the application of the μTBS test and proposed directions for further improvement of this testing method. Elsevier 2020-11 2019-11-25 /pmc/articles/PMC6888711/ /pubmed/31827652 http://dx.doi.org/10.1016/j.jdsr.2019.10.001 Text en © 2019 Published by Elsevier Ltd on behalf of The Japanese Association for Dental Science. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Article
Sano, Hidehiko
Chowdhury, Abu Faem Mohammad Almas
Saikaew, Pipop
Matsumoto, Mariko
Hoshika, Shuhei
Yamauti, Monica
The microtensile bond strength test: Its historical background and application to bond testing
title The microtensile bond strength test: Its historical background and application to bond testing
title_full The microtensile bond strength test: Its historical background and application to bond testing
title_fullStr The microtensile bond strength test: Its historical background and application to bond testing
title_full_unstemmed The microtensile bond strength test: Its historical background and application to bond testing
title_short The microtensile bond strength test: Its historical background and application to bond testing
title_sort microtensile bond strength test: its historical background and application to bond testing
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6888711/
https://www.ncbi.nlm.nih.gov/pubmed/31827652
http://dx.doi.org/10.1016/j.jdsr.2019.10.001
work_keys_str_mv AT sanohidehiko themicrotensilebondstrengthtestitshistoricalbackgroundandapplicationtobondtesting
AT chowdhuryabufaemmohammadalmas themicrotensilebondstrengthtestitshistoricalbackgroundandapplicationtobondtesting
AT saikaewpipop themicrotensilebondstrengthtestitshistoricalbackgroundandapplicationtobondtesting
AT matsumotomariko themicrotensilebondstrengthtestitshistoricalbackgroundandapplicationtobondtesting
AT hoshikashuhei themicrotensilebondstrengthtestitshistoricalbackgroundandapplicationtobondtesting
AT yamautimonica themicrotensilebondstrengthtestitshistoricalbackgroundandapplicationtobondtesting
AT sanohidehiko microtensilebondstrengthtestitshistoricalbackgroundandapplicationtobondtesting
AT chowdhuryabufaemmohammadalmas microtensilebondstrengthtestitshistoricalbackgroundandapplicationtobondtesting
AT saikaewpipop microtensilebondstrengthtestitshistoricalbackgroundandapplicationtobondtesting
AT matsumotomariko microtensilebondstrengthtestitshistoricalbackgroundandapplicationtobondtesting
AT hoshikashuhei microtensilebondstrengthtestitshistoricalbackgroundandapplicationtobondtesting
AT yamautimonica microtensilebondstrengthtestitshistoricalbackgroundandapplicationtobondtesting